5.
For VMC, use the 6-pole magnet to adjust the R andBdotsto
3-7. DEFLECTION YOKE NECK ROTATION
be symmetrical above and below the G dot. (*2)
ADJUSTMENT
#9:
If there is misconvergence at both sides on the X or Y axis of the
screen, turn the neck of the deflection yoke in the direction of the
R
G
B
Ae
arrow to reduce the misconvergence for the entire CRT screen to
within the tolerance.
.
FIX
;
1.
Reverse misconvergence pattern
LY
'
o
t
Reverse cross
Regular cross misconvergence
Y
misconvergence pattem
pattern
Move the deflection yoke
Move the deflection yoke
6-pole magnet
The VMC adjustment does not
change the opening of the 6-
pole magnet, but turns it left 24 Adjust so that the displacement
and right.
up and down are the same.
:
;
;
;
Pattern of left-sided
Pattern of right-sided
6.
Adjust by repeating the adjustments in Items 2 through 5.
deflection yoke
deflection yoke
(*3)
*3: The above adjustment may
affect the landing, so after
Move the deflection
»
Move the defiection
;
:
:
:
;
:
yoke to the right when
yoke to the left when
this adjustment, check the landing again.
viewed from the CRT
viewed from the CRT
7.
After the adjustment is complete, paint on the knobs to lock
screen.
screen.
them.
L
L
L
L
R
B
B
R
B
R
R
B
V.STAT magnet
Purity
20 inch