The line below initiates the broadcast FW OTA operation from the master at the desired speed using
previously set values for "method" and "reboot". The parameter following start is the speed argument
shown in the table below:
>app_ota start robust
OK
Querying status at the Master will then show:
>app_ota
Status: Active: 0%
To terminate a session at the Master use the "stop" argument on the command line:
>app_ota stop
OK
Checking status will show the following:
>app_ota
Status: Canceled
Avoid frequent queries on the UI during reprogramming – especially when using the faster
NOTE
transmission selections. It may interfere with successful transfer.
MDS 05-7280A01, Rev. A
Table 3-2. OTA broadcast speed controls:
Speed
Transmission
setting
Sequence
Repeat Count
robust
20
slow
10
medium
5
fast
2
turbo
2
MDS TransNEXT Technical Manual
Inter-Message
Delay
5 ms
50 ms
100 ms
150 ms
200 ms
49