Download Print this page

Wolf E Series SO30-2F/S Planning Information page 6

E series built-in single ovens
Hide thumbs Also See for E Series SO30-2F/S:

Advertisement

Planning Information
E Series Built-In Single Ovens
M O D E L S S O 3 0 - 2 F / S A N D S O 3 0 - 2 U / S
I N S T A L L A T I O N N O T E S
Refer to the illustrations and specifications
for overall dimensions, finished rough opening
dimensions and installation specifics.
For ease of installation, Wolf recommends
using a 33" (838) wide cabinet with the
E Series single oven in a standard installation
and a 36" (914) wide cabinet in a flush inset
installation. The cabinet base platform must be
able to support 250 lbs (113 kg).
Wolf E Series built-in ovens may be used in
a standard installation, where the face trim
overlaps stiles and rails, or in a flush inset
installation with the front of the oven flush with
surrounding cabinetry. Refer to the illustrations
on pages 4 and 5.
For standard installations, the oven is
installed by inserting into cabinetry from the
front. The oven has a face trim on all four sides
and will overlap stiles and rails. The trim
5
overlaps
/
" (16) on the top,
8
3
bottom and
/
" (19) on each side.
4
The flush inset installation requires the oven
to be recessed into the cabinet. A minimum 33"
(838) wide and 25" (635) deep cabinet is
needed if you want the front of the oven to be
flush with surrounding cabinetry.
For flush inset installations, the inside edges
of the rough opening must be finished, as
they will be exposed when the oven door is
open. These edges should be stained
instead of having a laminated surface, to
avoid damage from high temperatures
during self-clean.
E Series single ovens require a separate,
grounded 3-wire 240/208 V AC, 60 Hz, 30 amp
service with its own circuit breaker. Locate
the electrical supply within the shaded area
shown in the illustration for your specific
installation on pages 4 and 5.
Dimensions in parentheses are in
millimeters unless otherwise specified.
IMPORTANT NOTE: Unless you are using
cabinets deeper than 24" (610) for a standard
installation or 25" (635) for a flush inset instal-
lation, it is recommended that the electrical
supply be placed in an adjacent cabinet within
reach of the conduit. A 2" (51) diameter hole to
route the conduit through cabinetry will be
required. Refer to the Installation illustrations on
pages 4 and 5 for location of the electrical
supply for your specific installation.
regulations. In addition, be aware of local codes
and ordinances when installing your service.
below an induction, electric or gas cooktop.
Unless you are using cabinets deeper than 24"
(610) for a standard installation or 25" (635) for
a flush inset installation, it is recommended that
the electrical supply be placed in the base
cabinet to the right of the oven within reach of
1
/
" (3) on the
8
the conduit.
IMPORTANT NOTE: Wolf built-in ovens are
designed and agency approved for installation
with Wolf cooktops only. A built-in oven cannot
be installed below a Wolf rangetop. For addi-
tional specifications, refer to the induction,
electric and gas cooktop sections of our
website, wolfappliance.com.
combination with a Wolf microwave and
warming drawer. Refer to page 7 for specifica-
tions.
next to another E Series single oven. You must
allow for a 2
rough openings. Also, a separate inner wall is
required for each oven between openings.
shipped with each Wolf product for detailed
specifications.
You must follow all National Electrical Code
A Wolf E Series single oven may be installed
An E Series single oven may be installed in
The E Series single oven may be installed
1
/
" (64) space between the oven
2
Refer to the installation instructions
6

Advertisement

loading

This manual is also suitable for:

So30-2u/s