Compact Dyna-Star (Cds) Pump Assembly; Fitting Table; Pump Installation - Graco Compact Dyna-Star 132662 Installation Instructions Manual

Graco automatic lubrication system on the komatsu hd785
Table of Contents

Advertisement

Compact Dyna-Star (CDS) Pump
Assembly
1. Remove the fill port and cover, optional outlet 1/4 in.
npt plug, and 3/8 in. npt refill vent plug.
2. Install a 3/8 in. npt, 90° street elbow (A) and a 3/8 in.
npt x -6JIC adapter (D) at the lubricant output con-
nection port, fill port, and refill vent port.
B
C
D
A
F
. 24
IG
3. Install a 1/4 in. npt 90° street elbow (C) and the
pressure gauge (B) in the 1/4 in. npt port outlet.

Fitting Table

Ref
Description
a
3/8 in., 90° street elbow
b
Gauge
c
1/4 in., 90° street elbow
d
3/8 npt to -6JIC adapter
3A7633A
A
D
A
Qty
3
1
1
3
NOTE: Photographs may include optional equipment.

Pump Installation

LIFTING HAZARD
This equipment is heavy. Lifting or moving heavy
equipment incorrectly can cause serious injury such
as muscle strain or back injuries. To avoid injury:
Do not lift or move this equipment without assis-
tance.
Always use a lifting device secured to the pump lift
ring when moving or installing this equipment.
1. Hoist the reservoir onto the right side deck plate of
the haul truck using the eye-bolt on the CDS pump
(F
. 25).
IG
Eye-
bolt
F
. 25
IG
2. Position the reservoir so the motor is facing the rear
of the truck. This is the deck area without slip resis-
tant texture. (F
. 26).
IG
F
. 26
IG
Installation
15

Advertisement

Table of Contents
loading

Table of Contents