12-3-1 SEALED SYSTEM DIAGNOSIS
"Not Cooling" Complaint
All components operating, No airflow problems, Not frosted up as a defrost problem
problem has been isolated to sealed system area
Frost
Pattern?
Partial
None
Equalization
Test
Equalization
Test
Very Fast
Very Slow
Very Slow
Fast
Very Fast
Inefficient
Compressor
Complete
Restriction
Partial
Restriction
Condenser
Temperature
Cap Tube
Sound
Hotter than Normal
Room Temperature
None to Weak
Air/Low Side
Leak
Loss of Change
Compressor Not
Pumping
Trace of Oil
No
Undercharge
(The equalization test is trying to restart a compressor using a start kit after it has been operating.)