LG LMX25964 Series Service Manual page 34

Hide thumbs Also See for LMX25964 Series:
Table of Contents

Advertisement

9-3 Freezer room AC Bulb Lamp doesn't work
<CON3>
No
Checking flow
Result & SVC Action
1
Check the Freezer door switch.
If feel sticky, Change the door s/w.
2
Check the door S/W resistance.
| Status | Result |
SVC Action
002
Go to the 3
Normal
Other
Change door S/W
Push
Infinity
Go to the 3
S/W
Change door S/W
3
Check the Yellow Blue to Sky blue.
[Status | Result |
SVC Action
5V
Go to the 4
Closed
Other
Change the Door S/W
OV
Go to the 4
Open
Other
Change the Door S/W
<CON4>
4
Check the Blue to Black.
[Status | Result | SVEAction
0~2V
Normal
Closed
Other | Change the Main PCB
Open
115 V
Change the F Lamp
Other
Change the PCB
- 34-