LG LMX25964 Series Service Manual page 36

Hide thumbs Also See for LMX25964 Series:
Table of Contents

Advertisement

9-5 Poor cooling in Fresh food section
Cold or not?
No
Checking flow
Result & SVC Action
1
Check R-Sensor resistance.
[Temperature [Result
23°F / -5°C
38 kQ
32°F /0°C
30 kX
41°F /5°C
24 kQ
50°F / 10°C
19.5 kQ
<CON7>
59°F / 15°C
16 k&
* R-Sensor is determined by
the temperature.
For example, 30kQ indicates 32°F.
2
Reset the unit and
Input Test 1 Mode.
(Push the button 1 time)
ae
3
Open the fresh food door and
Check the air flow.
| Status
nn
Airflow
Go to the 4
Check the R Fan motor
No airflow
Check the damper
(Go to the 6)
4
Check the air temperature.
| Status |
SVC Action
Cold
Normal
Check the Compressor
Not cold
And sealed system
- 36-