en Troubleshooting
Fault
and programme
terminated.
Condensation in the
condensation tank
even though the water
drain hose is connec-
ted.
The programme does
not start.
The length of the pro-
gramme changes dur-
ing the drying cycle.
Pumping noise.
Buzzing noise.
The drying time is too
long.
48
Cause and troubleshooting
Water drain hose is blocked.
Rinse the water drain hose with tap water.
The filter for the condensation tank is soiled.
→ "Clean the filter for the condensation tank.",
Page 44.
The appliance uses condensation for the automatic
self-cleaning.
Not a fault – no action required.
Water drain hose is not connected correctly.
Ensure that the water drain hose is connected cor-
rectly.
→ "Connecting the water drain hose", Page 14
Childproof lock is activated.
→ "Deactivating the childproof lock", Page 36
has not been pressed.
Press
.
No programme set.
→ "Setting a programme", Page 32.
1.
→ "Starting the programme", Page 33.
2.
The programme operation is optimised electronically.
This may change the programme duration.
Not a fault – no action required.
Condensation pump active.
Not a fault – normal operating noise.
Compressor ventilation active.
Not a fault – normal operating noise.
Fluff filter is soiled.
→ "Cleaning the fluff filter", Page 33
The ambient temperature is greater than 30 °C.
Ensure that the ambient temperature is below 30
°C.
The ambient temperature is lower than 15 °C.
Ensure that the ambient temperature is above
15 °C.
Insufficient air circulation at the appliance's installation
location.
Ventilate the appliance's installation location.
The appliance's ventilation opening is blocked.