Download Print this page

Advertisement

Quick Links

DIGITAL BORE GAUGE
Thank you for purchasing the Digital Bore Gauge.
Please read this manual thoroughly before use for proper operation.
■ PART IDENTIFICATION
Gauge
LCD Display
(Digital Indicator)
[ ABS/SET ]
※2
Button
ABS
※1
[ ZERO/ON ]
ABS/SET
ZERO/ON
MIN
CAL
Button
[ MIN ] Button
[ CAL ] Button
Clamp
Screw
※1 :Not Used
※2:"0.01" indicates the resolution
of the displayʼs digital bar
graph.
The bar graph display will
Handle
change with each 0.01mm
change in the measured
value.
【Accessories】
Shaft
Extension Rod
0.5 mm
1mm
Extension
Washer
Rod
Probe Tip
Spanner
Measurement
※Spanner appearance
Guide
Head
may vary slightly
from drawing, but
function will be same.
■ INSERTING・REPLACING BATTERY
Pull out the case from
Battery
the two side edges to
(CR2032)
remove. Insert battery
with
+
side facing
(
)
down.
Battery
NOTICE
Case
Use only CR2032 type
lithium button cell.
■ AUTO OFF DELAY
①Press and hold the [ ZERO/ON ] Button to turn power
OFF.
②Press and hold [ ABS/SET ] and [ ZERO/ON ] Buttons
at the same time.
③When 「-----」 is displayed, ❶release the [ ZERO/ON ]
Button, ❷then release the [ ABS/SET ] Button in that
sequence.
④The Auto Off Delay time will be displayed. Press
[ ABS/SET ] to change.
※Each press of the [ ABS/SET ] Button will change the
delay by 1/2 hr. ( 30 min. ) from 0 to 6 hr.
⑤Press [ ZERO/ON ] when done and display will return to
the measurement screen.
※Once set, the delay time is saved even when power is OFF.
Instruction Manual
Model No.:WCDI-35D
■ SPECIFICATIONS
*Including supplied Digital Gauge
※Not including quantization error ( ±1 count )
Model No.
WCD I -35D
(mm)
Measuring Range
18 -35
(mm)
Resolution
0.0 02
(μm)
Wide range accuracy
15
(μm)
Adjacent error
(μm)
Repeatability
(mm)
Single Stroke Range
1. 2
0 〜 6.0
( hr )
Auto Off Delay
( g )
Weight
36 0
ACCESSORIES
● Extension Rods ・・・ 18・20・22・24・26・28・30・32・34mm (9pc.)
● Washer ・・・・・・・・・・ 0.5・1mm ( 1 each size )
● Spanner・・・・・・・・・・ 1x
● Battery ・・・・・・・・・・・ CR2032 Lithium button cell, 1x ( for test )
NOTICE
●This is a precision instrument, handle with care.
●Do not disassemble or modify.
●Keep instrument away from water and oil.
● Use only with supplied Extension Rods and Washer.
●Keep instrument away from direct sunlight and high temperatures
such as in a car, or near a stove or heat source.
● After use, remove any dirt or cutting chips and apply rust preventative
oil to Extension Rod and Washer. When not in use store in supplied
storage case.
●This product is for measuring inside diameter; use only as directed.
Improper use may cause accident or injury.
●Avoid using in high electric fields, such as near fluorescent lights or
switching power supplies. Electrical interference may cause incorrect
readings.
■ ASSEMBLY
①Loosen the Clamp Screw and insert the
Digital Indicator into the gauge body.
Tighten the Clamp Screw to secure.
※After attaching, press the [ ZERO/ON ]
Button on the Digital Indicator to turn on
power. Confirm that the displayed reading
changes by gently squeezing the
measurement head. If necessary, adjust
the depth that the Digital Indicator is
Clamp
inserted into the gauge body.
Screw
②Select the Extension Rod, washer for the desired measurement range.
【Examples】
To
Measure:
28
mm
Ex. Rod
28mm
To
Measure:
29.5
mm
Ex. Rod
Washer
Washer
28mm
1mm
0.5mm
■ MEASUREMENT
For accurate measurements, follow the procedure described below.
①In cross section perpendicular to the axis of the bore, as shown in Figure 1, position the gauge along diameter ⓐ. This is the
maximum distance, and at this point the Indicator will read the maximum value. The Measurement Head will automatically move to
diameter ⓐ when inserted.
②In cross section parallel to the axis of the bore through diameter ⓐ, position the indicator to minimize the distance ⓑ. ( Figure 2 )
In this position the Indicator will read the minimum value. This position must be manually determined by pivoting the Gauge as
shown in Figure 3 while watching the Indicator to find the minimum value.
5
3
(Fig.1)
■OPERATION
①Before use, please make sure the Measurement Head components are not loose and tighten if necessary.
②Clean the Measurement Head and the ID of a Ring Gauge Standard using parts cleaner or cleaning solution.
③Press the [ ZERO/ON ] Button to turn on power. ※ A long press to the [ ZERO/ON ] Button will turn power off.
ABSOLUTE MODE ( ABS )
①Turn on power. If the "
②Adjust the "SET" value of the Bore Gauge to match the ID of the Ring Gauge Standard. Press and hold the [ ABS/SET ] Button until
"SET" blinks on the display.
③Continue holding the [ ABS/SET ] Button and the display character to the left will blink. Use a short press of the [ ABS/SET ] Button to
change the value, and a long press to change the character being modified. Repeat this process to enter the dimension of the Ring
Gauge Standard on the LCD display. ( Figure 4 )
④When the value is entered the flashing position will return to "SET". A short
press of the [ ABS/SET ] Button to turn off the flashing.
⑤Insert the Measurement Head into the Ring Gauge Standard and press the
[ MIN ] Button to put the Indicator into minimum-mode. Slowly pivot the
gauge ( Figure 3 ) to display the minimum value.
⑥Remove the gauge from the Ring Gauge and press the [ CAL ] Button until
"OK" is displayed.
Preparation for measurement is now complete.
⑦Put the gauge into the workpiece to be measured, and pivot the gauge
slowly. ( Figure 3 ) The LCD will display the measured value. ( Figure 5 )
※Press the [ ON/ZERO ] Button momentarily to reset display in preparation
to measure the next workpiece.
COMPARATIVE MEASUREMENTS
ABS/SET
ZERO/ON
MIN
CAL
①Turn on power. If "
press the [ MIN ] Button to turn off. If "ABS" is displayed press the
[ ABS/SET ] Button to turn off.
②Insert the Measurement Head into the Ring Gauge Standard and press
[ MIN ] Button to put the Indicator into minimum-mode. Slowly pivot the
gauge ( Figure 3 ) to display the minimum value.
③Remove the gauge from the Ring Gauge and press the [ CAL ] Button until
"OK" is displayed.
Preparation for measurement is now complete.
④Put the gauge into the workpiece to be measured, and pivot the gauge
slowly. ( Figure 3 ) The LCD will display the difference between the
measured workpiece and the calibration standard. ( Figure 6 )
※Press the [ ON/ZERO ] Button momentarily to reset display in preparation
to measure the next workpiece.
■TROUBLESHOOTING
ERROR
●LCD does not display
●Displayed value is unstable
●Display is not clear
(Fig. 2)
(Fig. 3)
※Measure absolute dimension of workpiece
" or "
" symbols are displayed on the LCD, press the [ MIN ] Button to turn off.
※Difference between workpiece and reference
" or "
" symbols are displayed on the LCD,
※If problem persists, or if you have any
CORRECTIVE ACTION
questions, please contact distributor.
●Cycle power by removing and
※Please note, manufacturer is unable to
replacing battery.
respond to inquires or provide service
●Replace battery with new one.
directly. Please contact distributor.
ABS
ABS/SET
ZERO/ON
Ring Gauge
Standard
MIN
CAL
Set to match
(Fig. 4)
OK
ABS
SET
Work-
ABS/SET
ZERO/ON
piece
Workpiece I.D. value
MIN
CAL
(Fig. 5)
Work-
ABS/SET
ZERO/ON
piece
MIN
CAL
Diff. between Work-
piece and Reference
(Fig.6)
Niigata Seiki Co., Ltd.
5-3-14, Tsukanome, Sanjo, Niigata, Japan, 955-0055
Tel. : +81-256-33-5522 Fax. : +81-256-33-5518
MAIL intl.sales@niigataseiki.co.jp
URL
http://www.niigataseiki.co.jp

Advertisement

loading

Summary of Contents for Niigata seiki WCDI-35D

  • Page 1 ERROR CORRECTIVE ACTION delay by 1/2 hr. ( 30 min. ) from 0 to 6 hr. questions, please contact distributor. Niigata Seiki Co., Ltd. Measure: ⑤Press [ ZERO/ON ] when done and display will return to ●LCD does not display ●Cycle power by removing and...
  • Page 2 デジタルシリンダゲージ ■測定方法について 正確な数値を測定するために、測定は下記の手順で行ってください。 ①円筒の軸に垂直な断面において、直径 は最大値となり、指示器は最大値を表示します。 (図1) この度はデジタルシリンダゲージをお買上げ頂きありがと うございます。 この直径 は、可動する案内板によって自動的に求められます。 ご使用前に、 本書をよく お読み頂き正しく お使いく ださいますようお願い申し上げます。 ②直径 を通る円筒の軸に平行な断面において、直径 は最小値となり、指示器は最小値を表示します。 (図2) ■各部の名称 ■仕 様 この直径 は、手動で求めます。シリンダゲージを(図3)のように振り、指示器が最小値を示す点を探してください。 * : 付属のデジタルインジケータ (指示器) を含めた値です。 ※ 量子化誤差 (±1カウン ト) 含まず 指示器 LCD表示部 品         番 W C D I -35 D (デジタルインジケータ)...