Torque Switches - Promation Engineering P2-120PN4 Installation & Operation Manual

Proportional control

Advertisement

These units may be equipped with
internal torque switches which protect
FEEDBACK OUT
the gear train, motor and controlled
SIGNAL IN
equipment from damage when high
COMMON
torque conditions exist.
These protective devices are NOT
adjustable. More information on this
techology is found throughout this
manual.
NOT OPEN*
OPEN COM*
OPEN*
NOT CLOSED*
CLOSED COM*
CLOSED*
120VAC 230VAC
Neu
L2
Hot
L1
HOT/L2
GND GND
GND
Field wiring and
devices by others
Torque Switches (if equipped)
Actuator ships in fully closed position!
For units equipped with torque switches:
Torque switches provide mechanical
overload protection for both the actuated
device and the geartrain.
These are factory set and are not
adjustable without proper equipment.
Torque switches are set to limit actuator
torque to approximately 105% of the
actuator rated output.
The wiring diagram above shows the
internal wiring connections between
the control board, the torque switches
and the motor. The upper torque switch
controls loading in the CW direction,
while the lower switch controls loading in
the CCW direction.
OUT
IN
COM
COM
DIR
PWR
NC
NO
ALTERNATE SIGNAL IN
COM
12
AUXILIARY
11
SWITCH
SW4
(STANDARD)
10
9
AUXILIARY
8
SWITCH
SW3
(STANDARD)
7
6
SW1
5
4
J1
SW2
3
E2
E1
HEATER
2
1
J3
J2
GND Screw
Items within dotted line indicates internal components
Use For:
P4/5/6-120DN4-ISOFB-TS
WARNING! Do NOT adjust the
torque switch cam settings.
This will VOID the warranty.
Actuator
Voltage
Wire
Gage
Page 4 of 16 P2/3 HV Proportional Series
Actuator Specifi cations
Torque "lb/Nm
Supply Voltage
Max Inrush Current
GRY
Running Current
Motor
ORG
FEEDBACK
1
Runtime (90°@60Hz/vdc)
Close
BLU
J5
Runtime (90
@50Hz)
O
Duty Cycle
120VAC
230VAC
+4-20mA
2
4
2
4
Motor Starts
J2
J2
1
3
1
3
FEEDBACK OUT
(-)
Weight
OPTION
Mechanical Connections
J3
POWER
(+) 1-5, 0-5, 0-10vdc
Electrical Entry
6.3A
+4-20mA
Electrical Terminations
250V
F4
SIGNAL IN
J4
3AG
(-)
FACTORY
Environmental Rating
CONNECTOR
SLO
Manual Override
Control
Actuator Case Material
Motor Protection
Ambient Temperature
Operating Range
NOT OPEN*
OPEN COM*
OPEN*
THERMAL
* CONNECTIONS
SWITCH
Capacitor
NOT CLOSED*
OPTIONAL
M
CLOSED COM*
CLOSED*
AC DRIVE
MOTOR
RED
ALL SWITCHES
SHOWN WITH
ACTUATOR IN
L2 Neutral
FULL OPEN
POSITION
L1 Hot
GND
Wire Sizing Chart
MAX distance between Actuator and Supply (feet)
P2
120VAC
Amps
1.8A
722
16
1166
14
1783
12
3030
10
4523
8
P2
800"lbs/90Nm
120vac
230vac
1.8A
0.8A
1.3A
0.5A
POSITION
Split Phase Capacitor
15 sec
1K ohm
OTX-101
17 sec
Managed (75% maximum)
WHT18
+
1200 per hour
-
26lbs/12kg
8 (+15v OUT)
6
ISO F07 F10 22mm/Imp 3.5in BHCin ¾ X½ in
7
5
(2) ISO ¾" / Imp ½" NPT
6
4
12-16ga
5
3
NEMA 4/4X/IP67
4
2
5" Handwheel
3
1
2
Proportional
J1
WHT18
1
Aluminum Alloy, Powder coated
DHC-100
J2
230°F/110°C Thermal F* Class
*Totally Enclosed Non-Ventilated Motors
-22°F to +125°F
-30°C to +52°C
12
AUXILIARY
11
SWITCH
SW4
(STANDARD)
10
9
AUXILIARY
8
SWITCH
SW3
(STANDARD)
7
Gry
6
TSU
SW1
5
Blu
4
TSL
SW2
J1
3
E2
E1
HEATER
2
This motor wiring shows
1
J3
the wiring for the products
J2
equipped with the optional
Torque Switch (-TS).
GND Screw
Items within dotted line indicates internal components
Actuator ships in fully closed position!
Wire sizing data is provided in the table to
assist in the selection of the proper wire size for
ProMation actuators using various wire sizes
over distance.
Please make sure to reference the correct
voltage and do not exceed the indicated length
of the wire run for each model.
230VAC
120VAC
0.8A
1.8A
3111
722
5026
1166
7687
1783
13068
3030
19505
4523
P3
1335"lbs/150Nm
120vac
230vac
1.8A
1.2A
1.3A
0.5A
22 sec
26 sec
GRY
Close
POSITION
FEEDBACK
ORG
1K ohm
BLU
WHT
BLK
FACTORY
CONNECTOR
BLU
J4
RED
WHT
Gry
THERMAL
SWITCH
M
Capacitor
Blu
BLK
AC DRIVE
MOTOR
RED
ALL SWITCHES
SHOWN WITH
ACTUATOR IN
FULL OPEN
POSITION
GRN
P3
230VAC
1.2A
2074
3351
5125
8712
13003