Nordyne O4LD-091A-12-RA Installation, Operation And Maintenance Manual page 12

Oil fired warm air furnaces
Hide thumbs Also See for O4LD-091A-12-RA:
Table of Contents

Advertisement

Table A-5 Direct Drive Blower Set-Up
Blower Set-Up
Cooling Capacity
0.20 in. w.c.
0.50 in. w.c.
CFM
Furnace Model
Blower |
Speed
Motor
Speed
Motor
Tons
Power
Range
O4LD-070A-12-RA
10-10T
O4LD-070A-14-RA-DV
DD
Low
1/2 HP | Med-Low]
1/2 HP
3
1/2 HP | 700-1600
O4LD-091A-12-RA
10-10T
O4LD-091A-14-RA-DV
DD
Med-Low |
1/2 HP | Med-Low |
1/2 HP
3
1/2 HP | 700 — 1600
O4LD-105A-12-RA
10-10T
Med-
O4LD-105A-14-RA-DV
DD
Med-Low |
1/2 HP
High
1/2 HP
3
1/2 HP | 700 — 1600
Table A-6 Direct Drive Blower Characteristics
CFM
Furnace Model
Blower
itil
er
AT
Speed
External Static Pressure — Inches w.c.
0.2
0.3
0.4
0.5
0.6
O4LD-A-12-RA
High
1722
1645
1516
1462
1375
O4LD-A-14-RA-DV
Med-
1604
1545
1473
1383
1302
10-10T
°
High
DD
1/2 HP
7.1
70°F
Med-
L
1147
1133
1106
1063
1013
070 - 105
ow
Low
747
738
720
702
669
TIP: These Formulae will assist with the design of the ductwork and the determination of
aifflow delivery:
CFM = Bonnet Qutgut
'(1.085 x System Temperature Rise (AT)
System Temperature Rise (AT) = Bonnet Output / (1.085 x CFM)