IDLE STATE
A
THERMOSTAT
CALLS
FOR HEAT
OIL PRIMARY
CONTROL
v
SEQUENCE
OF
SAFETY CHECK FOR FLAME (5 SEC.)
REMAINS
IN IDLE STATE
OPERATION
A
NO FLAME
4
BURNER
MOTOR
& IGNITOR START
FLAME
10 SEC.
v
SAFETY CHECK FOR FLAME (5 SEC.)
NO FLAME
v
FLAME
SOLENOID VALVE OPENS
LOCKOUT
STATE
Y
TRIAL FOR IGNITION
Vv
OIL PRIMARY CONTROL:
¥
e
Shuts off burner motor
BURNER FLAME MONITORED
a
¢
Shuts off igniter
e
Shuts off Solenoid Valve
NO FLAME
e
Fast Flashes LED Diagnostic
FLAME
'
Light
CARRYOVER
STATE
e
Provides continuous spark
e
LED diagnostic light ON
e
§=© Start Carryover Timer
TOEXI] LOCKOUT
FLAME
LOST
PRESS
RESET
FLAME
v
CARRYOVER
TIMER EXPIRES
FLAME
LOST
FLAME
1
RUN STATE
¥v
*
Igniter turns T
FLAME LOST
RECYCLE TIMER STARTS
THERMOSTAT
SATISFIED
y
y
OIL PRIMARY CONTROL:
OIL PRIMARY CONTROL
e
Shuts off Solenoid Valve
SHUTS
OFF:
e
Shuts
off Igniter
e
Burner Motor
e
=©Shuts off Burner Motor
e
Solenoid
Valve
e
Slow
Flashes
LED
diagnostic light
30 SEC.
v
SAFETY CHECK FOR FLAME (5 SEC.)
y
RECYCLE TIMER EXPIRES
NO FLAME
(60 SECONDS
FLAME
RETURNS TO IDLE STATE