469220-UM V1.2Configuration TabStatistics TabThe fields in the table are: Primary/Backup Port: Configured UDP port for primary/backup. Primary/Backup Address: Configured reception IP address for primary/backup. Primary/Backup Source: Configured source IP address for primary/backup. If thesetting is to receive from any source, this field will contain the word Any. Primary/Backup State: This indicates which setting is online (active) and which settingis offline. The indicator has the following possible values: : This indicates that the setting is online (active). : This indicates that the setting is offline (inactive). Switch Time (sec): This indicates the automatic redundancy switch time, in seconds. Ifmanual redundancy is configured, the value displayed here is 0 (zero). In the exampleabove, Port 1/1 is in automatic redundancy with a switch time of 5 seconds, while
Port 1/2 is in manual redundancy. Manual Redundancy Switch: This control is in the configuration tab only. If you clickon this button, a manual redundancy switch is initiated. The button is available for bothmanual and automatic redundancy modes. Note that, if the port is in automatic
redundancy mode, and you manually switch it to a stream that is not running, it will
switch back to the running stream after the configured switch time.Connection RedundancyA populated Address/Port Redundancy table is depicted below. The only difference between the
Configuration and Statistics area is that the former includes a Switch button; otherwise they arethe same.