English
Installation and Use
WARNING!
For use in personal fall
protection systems only. NEVER use
for material handling and/or lifting.
Do not install at any angle
other than horizontal.
Do not use in combination with
pass-through anchors.
Do not use for Fall Arrest and Fall
Restraint simultaneously.
When using for Fall Arrest, user must
be equipped with with means of
limiting the the maximum dynamic
forces exerted onto each user during
a fall to a maximum of 6 kN.
Ensure all PFAS equipment is selected and
deemed compatible by a Competent Person.
Determine desired location for Web HLL; ensure
location is free of debris, rot, decay, cracking, and
hazardous materials. Eliminate or minimize all risk
of swing fall.
If using an SRL to connect to WEB HLL, only
Guardian ATOM and FAB3W SRLs up to 3m can
be connected.
WARNING!
Do not use retractable
type fall arresters (SRLs) or guided
type fall arresters, including a flexible
anchor line, that have not been
listed above with this horizontal
lifeline. Equipment which has
not been tested for compatibility
with this horizontal lifeline may
not function correctly, potentially
resulting in serious injury/death.
Step 1
Determine intended system length (maximum
20m) and anchor point installation locations.
Anchor points must be directly across from each
other, so that Web HLL will be completely level
and not slope in any way when installed.
Step 2
Install Cross Arm Straps around compatible
structural anchor points, as determined by a
Competent Person.
Note: it is also permitted to connect Web HLL
to anchorage connectors other than Cross
Arm Straps, provided applicable anchorage
connectors are deemed compatible with Web
HLL by Competent Person.
Step 3
Slide O-rings onto webbing before attaching
Ratchet Assembly.
5
Need help?
Do you have a question about the WEB HORIZONTAL LIFELINE and is the answer not in the manual?