Download Print this page

Mitsubishi Electric Mr.SLIM PUHZ-RP35VHA2 Service Manual page 8

Split-type, heat pump air conditioners
Hide thumbs Also See for Mr.SLIM PUHZ-RP35VHA2:

Advertisement

4
FEATURES
PUHZ-RP35/50VHA2
PUHZ-RP35/50VHA2
PUHZ-RP35/50VHA3
CHARGELESS SYSTEM
PRE-CHARGED REFRIGERANT IS SUPPLIED FOR PIPING LENGTH AT SHIPMENT.
Max.30m (PUHZ-RP35/50/60/71/100/125/140)
The refrigerant circuit with LEV (Linear Expansion Valve) and power receiver always control the optimal refrigerant
level regardless of the length (30m max. and 5m min.) of piping. The additional refrigerant charging work during
installation often causes problems. It is completely eliminated by chargelss system. This unique system improves the quality
and reliability of the work done. It also helps to speed up the installation time.
REFRIGERANT LEAKAGE DETECTION FUNCTION
PUHZ-RP•HA2/HA3 series can detect refrigerant leakage which may happen during a long period of
use.