Advertisement

WID70008
Model 700 User Manual Revision 1
Tru-Test Model 700
User Manual

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 700 and is the answer not in the manual?

Questions and answers

Summary of Contents for Tru-Test 700

  • Page 1 WID70008 Model 700 User Manual Revision 1 Tru-Test Model 700 User Manual...
  • Page 2 © 1997 Limited TRU-TEST No part of this document may be photocopied or reproduced without the prior written consent of Limited. TRU-TEST...
  • Page 3: Table Of Contents

    Contents Contents About This Manual ...........1 System Overview ............3 Installation ..............6 Calibration..............8 Operation ..............9 Safety ..............9 Keypad ..............10 Display ..............10 Switching On............11 Weighing..............11 Switching Off............12 Automatic Power Off ...........12 Changing Units of Measurement ......13 Zeroing ..............14 Power Up Zero .............14 Automatic Zero ............14 Manual Zero............15 Recording Statistics..........16...
  • Page 4 Contents Keys ..............20 Display Pointers ...........22 Display Messages..........23 Care and Maintenance..........26 Internal Battery ............27 Internal Battery Charging........28 Troubleshooting............30 Service Centres ............36 Technical Information ..........38 Autoranging ............38 USA Model Indicators ..........39 FCC Warning ............39 Model 700 Specifications ........40 Index .................43...
  • Page 5: About This Manual

    About This Manual About This Manual About This Manual This manual tells you how to operate the Model 700 TRU-TEST Indicator - the keyboard and display unit for the TRU-TEST Series agricultural weighing system. Models 701, 702 and 703 are more advanced Indicators which are described in separate manuals.
  • Page 6 About This Manual TRU-TEST Model 700 Agricultural Weighing System...
  • Page 7: System Overview

    System Overview System Overview System Overview 700 Series is an advanced and versatile TRU-TEST agricultural weighing system. It has been designed with the benefit of many years of animal weighing experience and is used by farm management professionals and agricultural scientists the world over.
  • Page 8 • The two more advanced models (702 and 703) can be printer to print results, or to a connected to a TRU-TEST computer for storing and further processing data. Reliability • Indicator is a rugged and robust product...
  • Page 9 System Overview Main Features • LIVE Weighing Mode. • Provides STATISTICS on recorded data. • FLEECE (FINE WEIGHT) Mode for better precision at low weights. • ZERO controls. • Span Calibration using known weights if required.
  • Page 10: Installation

    When you unpack your new Indicator, complete and post the warranty card to ensure you receive the service you are entitled 700 Series System Unpack and install the Indicator mounting stirrup in a convenient position. Ensure that it is located securely.
  • Page 11 Installation Install the Loadbars or Suspension Cells according to the manual which comes with them ( Loadbars TRU-TEST Manual). Run the Loadbar cables to the Indicator, making sure they are protected from damage. Unscrew the protection caps from the cable plugs and the Indicator sockets marked CELL1 and CELL2.
  • Page 12: Calibration

    Installation Calibration The Indicator automatically identifies and calibrates itself to the Loadbars connected to it. This is known as Standard Calibration. Span Calibration with known weights can also be carried out. (See your Service Centre). TRU-TEST...
  • Page 13: Operation

    Operation Operation Operation Operating the Model 700 is straightforward and TRU-TEST logical. Many functions are performed with a single key press. Safety To avoid damage, never load the scale further if the overload message appears on the display.
  • Page 14: Keypad

    0.5kg or 1.0kg division size. The division size close to zero (base resolution) depends on the Loadbars fitted. (See your Loadbars Manual.) TRU-TEST The division size automatically changes at particular weight limits to reflect the accuracy of the scale. (See Autoranging on page 38.)
  • Page 15: Switching On

    Operation Switching On If there is no internal battery, connect the 12 volt supply, red lead to the positive terminal, black to negative. Press . Display shows: The scale zeroes itself automatically (if Power Up Zero is On, see page Current weight: Weighing Normally the display shows the current live weight on the...
  • Page 16: Switching Off

    Press Disconnect the power supply if required. Automatic Power Off Model 700 automatically switches Off after TRU-TEST 30 minutes if no change in weight or key press is detected. This conserves battery life when the scale is not being used.
  • Page 17 Operation • To change the units, press...
  • Page 18: Zeroing

    Zeroing Zeroing Zeroing Model 700 has three methods of zeroing the TRU-TEST scale: • Power Up Zero • Automatic Zero • Manual Zero Power Up Zero The scale normally zeroes itself on power up, ie. when it is turned On. The weight of the platform or crate on the Loadbars is zeroed.
  • Page 19: Manual Zero

    Zeroing To change the Automatic Zero setting (On or Off): • Press The new setting is displayed for about 1 second. If Automatic Zeroing is On, Manual Zeroing is usually unnecessary, unless the weight being zeroed is relatively large and is outside the range for Automatic Zeroing (6 divisions maximum).
  • Page 20: Recording Statistics

    Recording Statistics Recording Statistics Recording Statistics Model 700 has the ability to record and display TRU-TEST statistics during the weighing session. Ensure that previous statistics are cleared before starting a weighing session (see Clearing Statistics on page 18). As each animal moves onto the platform: Wait for the Stable pointer to come on.
  • Page 21: Viewing Statistics

    Recording Statistics Viewing Statistics To view the statistics, press The following information is displayed in sequence as you keep pressing the key. COUNT Number of animals weighed. TOTAL Sum of all the weights of all the animals weighed. AVERAGE Average weight of all the animals weighed.
  • Page 22: Clearing Statistics

    Recording Statistics Clearing Statistics To clear the current set of statistics and start a new set: Press Press again to confirm, or press any other key to return to the current live weight without clearing the statistics.
  • Page 23: Fleece (Fine Weight) Mode

    300kg (660lb) with weight changes as small as 0.1kg (0.2lb). Weight changes as small as 0.05kg (0.1lb) can be measured using a single Loadbar system (see the Loadbars TRU-TEST manual). To change Fleece (Fine Weight) Mode status (On or Off): Press (Fine Weight).
  • Page 24: Quick Reference Section

    Quick Reference Section Quick Reference Section Quick Reference Section Keys Sets Automatic Zero tracking (On or Off). Clears memory. Press again to confirm, or press any other key to abort the clear operation. Displays battery/supply voltage and diagnostic information. Press any other key to return to live weight.
  • Page 25 Quick Reference Section Statistics. Press for Count, Total, Average, Minimum, Maximum in sequence. Press any other key to return to live weight display. Cancels out dirt and excrement accumulated on the platform and returns the display to exactly zero.
  • Page 26: Display Pointers

    Quick Reference Section Display Pointers SPAN Shows that the Span Calibration option is being used. (For Service Centres' use only.) STABLE Shows that the reading is stable. Shows that the displayed weight is in kilograms. Shows that the displayed weight is in pounds. RECORDED Current weight has been recorded.
  • Page 27: Display Messages

    Quick Reference Section Display Messages Message Meaning 12.5 Volt Power supply voltage. First press of DIAG key. Average weight statistic. Bad Code Bad code from Loadbar cable plug. Bad Conf Configuration data is lost. Busy Busy performing sorting or calculations. Cal Lost Standard Calibration data lost.
  • Page 28 Quick Reference Section Minimum (low) weight statistic. Lo Bat Low supply voltage indicated. No Cell No Loadbar is connected. No Rec'd RECORD key pressed but weight has already been recorded for this animal. No Trade Not legal for trade. Not Stbl Not stable when attempting to record.
  • Page 29 Quick Reference Section Zeroing The Indicator is Zeroing.
  • Page 30: Care And Maintenance

    Care and Maintenance Care and Maintenance Care and Maintenance Model 700 Indicator is a rugged and robust TRU-TEST product, designed to withstand the environment associated with livestock handling. The case is made from extremely tough, ultraviolet - resistant polycarbonate. The keyboard is completely sealed for all - weather operation.
  • Page 31: Internal Battery

    Refer all servicing matters to your Service Centre. The case is a sealed TRU-TEST unit and, if opened, moisture could affect the operation of the Indicator. The product warranty becomes void if the case seal is broken.
  • Page 32: Internal Battery Charging

    The internal battery charger operates from either the recommended power supply unit or a 12 volt car TRU-TEST battery. Other charging supplies may damage the Indicator resulting in the warranty becoming void. When charging the indicator from a car battery, the car battery will lose energy equivalent to leaving the car headlights on for approximately 1 hour.
  • Page 33 Care and Maintenance • To read the voltage, press Press any other key to return to live weight display. A fully charged internal battery reads 12.5 volts or more when the indicator has been on for 5 to 10 minutes with no Loadbars or external power source connected.
  • Page 34: Troubleshooting

    Troubleshooting Troubleshooting Troubleshooting "8 Volt" displayed Cause The internal 8 volt supply (used to supply the Loadbars) is outside its specified limits. Solution Disconnect the Loadbar cables from the Indicator one at a time. If the "8 voLt" message disappears then there is a fault in the Loadbars or their cables.
  • Page 35 Troubleshooting If the Indicator is not using Span Calibration then it may still be used without its Standard Calibration but with reduced accuracy. The accuracy cannot be guaranteed. Return the Indicator to your Service Centre to have its Standard Calibration data cleared or restored. "CS Fault"...
  • Page 36 Troubleshooting Solution Ensure animal correctly positioned on the platform. "High Bat" displayed Cause The supply voltage is greater than 16 volts DC. This message is displayed for 15 seconds and then the Indicator switches itself Off. Solution Replace power supply with a unit that can provide 10.5 to 16 volts DC.
  • Page 37 Troubleshooting Solution The Indicator can be used without the Loadbars connected for setting up. If the condition persists when the Loadbar cables are plugged in, refer to "bAd codE" above. Cause Old code 99 Loadbars are being used. Solution Contact your Service Centre for reconfiguration of the Indicator to recognise 99 as a valid code.
  • Page 38 Troubleshooting Solution If configured to do so, and if standard Loadbars are being used, the Indicator may continue to function using Standard Calibration although possibly with different resolutions and load ratings and with reduced accuracy. If you need to use Span Calibration, the system must be re-calibrated in situation.
  • Page 39 Troubleshooting • faulty Indicator. Solution Carefully tighten loose Loadbar feet lock nuts and ensure that all four feet are resting on concrete or 25mm (1 inch) of timber. If a Loadbar or the Indicator is faulty, return faulty item to your Service Centre. See also "Weights are out by a factor of nearly two".
  • Page 40: Service Centres

    Troubleshooting Service Centres If after carrying out the above recommended solutions to the various problems the fault has not been rectified, contact your local TRU-TEST Service Centre: New Zealand Phone Facsimile Toll Free (09) 274 5799 (09) 274 6367 0800 653 356...
  • Page 41 Troubleshooting Pressing DIAG four times gives the information in the following sequence: Supply voltage Model numbers, language and software version. PCB type, memory size and Loadbar code. Configuration number. Press any other key to return to current live weight display. Write the diagnostic information here: ___.__ Voltage...
  • Page 42: Technical Information

    5kg (10lb) capacity The live capacity of the scale is usually a round multiple of the base resolution, for example: 3000 x 0.5kg = 1500kg. Refer to the Loadbars Manual for live capacities of TRU-TEST Loadbars and Suspension Cells. TRU-TEST...
  • Page 43: Usa Model Indicators

    USA Model Indicators have some different key names from the standard model. See Keys on page 20. FCC Warning The TRU-TEST Indicator has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules.
  • Page 44: Model 700 Specifications

    Model 700 Specifications Model 700 Specifications Model 700 Specifications Analogue input Loadbar excitation: 8 volts DC, 4 wire, 6 x 350 ohm loadcells max. Sensitivity: 3 microvolts/division minimum. Full Scale: 14mV max. including dead load. Accuracy Standard Calibration (System): ±...
  • Page 45 Model 700 Specifications Zero controls Push button Zero: For span cal ± Maximum weight which can be zeroed is 2% of live capacity. For std cal or 50% deadweight allowance option: Any weight up to live capacity may be zeroed.
  • Page 46 Model 700 Specifications Environmental Operating temperature: -10 to +40°C (+15 to +105°F). Storage temperature: -20 to +80°C (-5 to +175°F). Humidity: 95% relative humidity. Case is proof to IP53 moisture and dust. Physical dimensions Display: 8 by 7-segment LCD. Height 18mm (3/4 inch).
  • Page 47 Model 700 Specifications Note: Product Specifications may change without prior notice.
  • Page 48: Index

    Index Index Index Fleece Mode Accuracy Automatic Power Off High Bat message Automatic Zero Autoranging Installation Average statistic Internal battery life Bad Code message specification Bad Conf message Battery Keypad installation Kilograms - units life Lo Bat message Cal Lost message Load - maximum Calibration 8, 30...
  • Page 49 Index Power supply display voltage Zero Ol message internal battery Zeroing Power Up Zero Auto Zero PR Fault message Manual Zero Power Up Zero Ready message Resolution autoranging Safety Service message Span cal pointer Span Calibration Spc Lost message Stable Pointer Standard Calibration Statistics Suspension Cell...

Table of Contents