Uses Abbreviations LC T-T= LactoCorder T-T The following names or signs are used in the operating instructions for particularly important information: Attention Indications of risk of injury to persons or risk of...
________________________________________________________________________ Special provisions Attention The LactoCorder T-T is an electronic high-tec measuring instrument that has to be treated with care. The following actions and applications are prohibited and release the manufacturer from any warranty: 1. Immersion or cleaning with high pressure...
________________________________________________________________________ Appropriate use The LC T-T is only used to check the quality and quantity of animal milk. Any other use or in excess is considered improper as intended. The resulting damages the manufacturer is not liable. The user bears the risk alone. The intended application also includes the observance of instructions and compliance with the inspection and Maintenance conditions.
________________________________________________________________________ Safety 2.7.1 General The design of the LC T-T corresponds to the current state of technology and is reliable. The individual modules as well as the complete device are tested by our quality assurance. Only use the device when it is in perfect condition and in accordance with its intended purpose, consciously taking into account the operating instructions.
________________________________________________________________________ 3 TEST FLUID FOR WATER TESTS To preserve the test liquid for the water tests, mix 45 ml Neoagrar with 15 l Water. This mixture should have a conductivity between 5.5 and 6.5mS. 4 SETTING THE LC T-T IN STABLE The LC T-T can be hung with hanging brackets or plug-in brackets or positioned in the stable.
________________________________________________________________________ LC T-T_empty after each measurement 5.15 Press button "5" (empty after measurement) Select if the LC T-T should be emptying or not after each measurement. (Our proposal is to choose for milk quantity measurement without emptying) Press the "1" button (without emptying), the LC T-T will not be emptied.
________________________________________________________________________ 7 Add the amount of the gap to the total quantity of milk? It depends on the measurement procedure if the content of the sampling may be added on the LC T-T for the total or not. Milk quantity measurement and sampling at the same time Where sampling and milk quantity measurement are carried out jointly, the amount of milk split off from LC T-T may be added to the quantity of milk.
________________________________________________________________________ 8 Calculation of the amount of milk when measured without emptying If the milk quantity measurement is checked without emptying, the remaining volume (difference volume) in the LC T-T has to be taken into account. The storage level in the LC T-T is always different at the end of a measurement. This milk quantity difference that must be taken into account.
________________________________________________________________________ 9 Battery management The LC T-T uses a lithium-ion battery with 4400 mAh. The battery indicator above on the right provides information about the capacity state of the battery. The following states are distinguished: Icon Battery condition Measures Battery 100% charged No measures Battery 85% charged No measures...
________________________________________________________________________ 10.3 Cleaning takes longer than there is space in the online data A maximum of 90 min. online values can be recorded during a cleaning process. If a cleaning takes more than 90 min. it will indicate that a RAM overflow has occurred and that the online readings are not complete.
Page 13
________________________________________________________________________ expected milk quantity Battery status (0: full, 1: 2/3, 2: 1/3, 3 almost empty, 4 empty) Total milking Species 11.3 Write data to USB stick: 11.3.1 Turn on LC T-T 11.3.2 Insert the USB stick on the LC T-T 11.3.3 Switch to the next menu with the "Enter"...