Heatilator ST42A Installation Manual page 12

Woodburning fireplace
Table of Contents

Advertisement

D. Frame the Fireplace
NOTICE:
+HDUWK H[WHQVLRQ GHVLJQ PXVW EH GHWHUPLQHG
EHIRUH LQVWDOODWLRQ RI ¿UHSODFH
,I WKH ¿UHSODFH LV SODFHG RQ WKH ÀRRU WKH PD[LPXP KHLJKW
RI D ¿QLVKHG UDLVHG KHDUWK LV   LQ  PP  LI \RX ZDQW
D KLJKHU UDLVHG KHDUWK WKH ¿UHSODFH PXVW EH SODFHG RQ D
platform.
WARNING! Risk of Fire!
DQFHV VSHFL¿HG
A minimum 1/2 in. (13 mm) air clearance must be
PDLQWDLQHG DW WKH VLGHV RI WKH ¿UHSODFH DVVHPEO\
Chimney sections at any level require a 2 in. (51 mm)
minimum air space clearance between the framing and
chimney section.
WARNING! Risk of Fire!
mum air space clearances to combustibles. DO NOT pack
required air spaces with insulation or other materials.
)LJXUH  VKRZV D W\SLFDO IUDPLQJ XVLQJ  [  OXPEHU RI
WKH ¿UHSODFH DVVXPLQJ FRPEXVWLEOH PDWHULDOV DUH XVHG
$OO UHTXLUHG FOHDUDQFHV WR FRPEXVWLEOHV DURXQG WKH ¿UH-
SODFH PXVW EH DGKHUHG WR 6HH )LJXUH  $Q\ IUDPLQJ
DFURVV WKH WRS RI WKH ¿UHSODFH PXVW EH DERYH WKH OHYHO RI
WKH WRS VWDQGR V
CAUTION!
Risk of Cuts/Abrasions. Wear protective gloves
and safety glasses during installation. Sheet metal edges
are sharp.
127( %HIRUH IUDPLQJ XS WKH FKDVH FRQVLGHU ZKHUH DQG
KRZ WKH FKLPQH\ ZLOO UXQ ,I WKHUH DUH REVWDFOHV WKDW PLJKW
EH LQ WKH ZD\ LW PD\ EH QHFHVVDU\ WR PDNH WKH FKDVH
ODUJHU WKDQ VKRZQ WR DOORZ IRU R VHWV WR EH XVHG 5HIHU WR
R VHW FKDUW RQ SDJH  LI QHHGHG
E. Secure and Level the Fireplace
7KLV ¿UHSODFH PD\ EH SODFHG RQ HLWKHU D FRPEXVWLEOH RU
QRQFRPEXVWLEOH FRQWLQXRXV ÀDW VXUIDFH )ROORZ WKH LQVWUXF-
WLRQV IRU IUDPLQJ LQ 6HFWLRQ  6OLGH WKH ¿UHSODFH LQWR SRVL-
WLRQ %H VXUH WR SURYLGH WKH PLQLPXP  LQ DLU FOHDUDQFH
DW WKH VLGHV RI WKH ¿UHSODFH
7KH ¿UHSODFH VKRXOG EH SRVLWLRQHG VR WKH IDFH RI WKH QRQ
FRPEXVWLEOH PDWHULDO RQ WKH ¿UHSODFH ZLOO EH ÀXVK ZLWK WKH
IDFH RI WKH GU\ZDOO RQ WKH ZDOOV
/HYHO WKH ¿UHSODFH DQG VKLP DV QHFHVVDU\
12
Comply with all minimum clear-
You must comply with all mini-
Heatilator • ST42A Installation Manual • 4012-051 • Rev O • 02/22
WARNING! Risk of Fire!
loose insulation.
DO NOT install against vapor barriers or exposed
insulation.
Secure insulation and vapor barriers.
Provide minimum air space clearances at the sides and
EDFN RI WKH ¿UHSODFH DVVHPEO\
17 in. (368 mm)
framing
3-1/2 in.
(89 mm)
3-1/2 in.
(89 mm)
(1219 mm)
27 in.
(686 mm)
Figure 3.5
Framing the Fireplace
1RWH ,I D ORDG EHDULQJ KHDGHU LV UHTXLUHG FRQVWUXFW D
VWDQGDUG  [  KHDGHU DQG LQVWDOO DW  LQFKHV XS IURP WKH
EDVH RI WKH ¿UHSODFH 7KLV PD\ EH GRQH SULRU WR VHWWLQJ
WKH ¿UHSODFH DV LW ZLOO VOLGH LQ EHORZ WKH KHDGHU $IWHU WKH
¿UHSODFH KDV EHHQ VHW LQWR WKH IUDPLQJ FDYLW\ ¿OO LQ EHORZ
WKH KHDGHU DV VKRZQ LQ )LJXUH 
Prevent contact with sagging,
Fireplace must be set out
1/2 in. (13 mm) in front of
1/2 in.
the face of the framing
(13 mm)
12 in. (305 mm) max.
Note: Fireplace
header cannot be
positioned until after
the fireplace assembly
is in place and set on
edge. The 2 x 4s above
the header will lay flat.
48 in.