Wall
| 5-13/16"
Transition
Centerline
10-1/4"
18"
i i
|
Fat
pf
£
Figure 8: Transition Centerline for Vertical Discharge
Duct covers, sold separately, are available to cover the
space between the top of the hood and ceiling. (See
page 3.)
12. Before hanging hood, install transition per Figure 7.
Fasten transition with two (2) screws (#8 x 3/8 sheet
metal, supplied) and tape per all applicable codes.
Note:
Screws must not hinder damper operation.
13. Rest the hood on the screws in the wood bracket. Use
the keyholes labeled "I" in Figure 9. Make sure the
wood bracket fits into the recess on the back of the
hood.
Figure 9: Location of Screw Keyholes
14.
Remove
knockouts.
15. Tighten the screws in keyholes. Check hood jevelness
and adjust if necessary.
16. From inside the hood, drive screws (#8 x 5/8") through
holes in hood into wooden bracket. See holes labeled
"J" in Figure 9.
17. Connect additional ducting.
Installation Note:
If wall studs are within 8" of the center line, cut stud at an
angle to avoid any interference.