Error Messages - Rinnai RHFE-1004FA Owners & Installation Manual

Energysaver gas direct vent wall furnace
Hide thumbs Also See for RHFE-1004FA:
Table of Contents

Advertisement

ERROR MESSAGES
_The
Energysaver 1004 has the abilityto check its own operation continuously. If a fault occurs, an Error Message
will flash on the Digital Display of the controlpanel. This assists with diagnosingthe fault, and may enable you to |
overcome a problem without a service call. Please quote the code displayed when inquiring about service,
j
FAULT
REMEDY
Check gas is turned ON.
Ignition failure
Service call if repeated.
Flame failure
Check gas is turned ON.
Service call if repeated.
Clean filter
Overheat
Service call if repeated.
Lower room temperature
Room overheat
to lessthan 40°C(104°F).
CODE DISPLAYED
11
12
14
16
31
32
33
34
53
61
70
71
72
73
49
99
Room Temperature
Sensor faulty
Overheat Temperature
Sensor faulty
Service
call.
Service call.
Sparker failure
Service call.
Combustion fan failure
Service call.
Faulty ON/OFF switch
Service call.
Faulty solenoids
Service call.
Faulty Flame Rod
Service caII.
Communication
Error
Turn heater OFF,
then ON again.
Sensor breakdown
Service Call.
Flue block
Check around flue terminal
I
In all cases, you may be able to clear the Error Message simply by tuming the heater OFF, then ON again. '_
J
If the Error Message s_ll remains or returns on the next operation, contact Rinnai or your nearest sewice
agent and arrange for a service call.
m33m

Advertisement

Table of Contents
loading

Table of Contents