ACCE
PROBE
600-20.
The
80T-I50C Temperaiurc
Probe
converts
your instrument
into
a direct-reading
(1
mV
dc/degree)
Celsius
thermometer.
It
is
suited for
surface,
ambient,
and
some
liquid
measurements.
A
rugged, fast-responding
probe
lip
with
a
350V
dc standoff
capability
makes
the
80T-150C
a
versatile
and
easy-to-use
temperature
probe.
600-21.
Temperature
Probe, Fahrenheit
80T-150F
600-22.
The
80T~150Fis
the as the
80T-150C
except the
80T-150F
is
set
to
read
in
degrees Fahrenheit.
600-23.
Current Transformer
801-600
600-24.
The Model
801-600 Current
Transformer
extends
the
maximum 2A
ac current measuring
limit
of
the
8050A
to
a
maximum
of
600A.
The
clamp-on
transformer design allows
measurements
to
be
made
without breaking
the
circuit
under
test.
Because
of a high-
efficiency,
quadrature-type of winding, wire
size
and
location
of
the
conductor
within the transformer jaws
do
not
affect
the
accuracy
of the current
measurement.
600-25.
Current
Shunt
80J-10
600-26.
The Model
80J-10 Current Shunt extends
the
current meavsuring capability of
your meter
to
lOA
continuous
(20A
for
periods not exceeding
1
minute)
dc
to 10
kHz
at
an
accuracy of
±
0.25%.
600-27.
High
Voltage
Probe
80K-6
600-28.
The Model 80K-6 High
Voltage
Probe
extends
the
voltage
measuring
capability
of
your meter
up
to 6
kV.
Internally,
the
probe
contains a
1000:1 divider.
The
divider
is
made
with
special
metal
film resistors
with
matched
temperature
coefficients,
providing the
probe
with
excellent
accuracy
and
stability characteristics.
Also,
the
very high input
impedance
(75
MO)
minimizes
circuit
loading,
thus contributing
to
measurement
accuracy.
The
plastic
housing
provides
for
operator
safety
while
measuring
potentially
dangerous
voltages.
600-29.
High
Voltage
Probe 80K-40
600-30.
The Model
80K-40 High
Voltage
Probe
extends
the
voltage
measuring
capability
of your meter
up
to
40
kV.
Internally,
the
probe
contains
a
1000:1 divider.
The
divider
is
made
with
special
metal
film resistors
with
matched
temperature
coefficients,
providing
the
probe
with excellent
accuracy
and
stability characteristics.
Also,
the
very high input
impedance
(1000
MH)
minimizes
circuit
loading, thus
contributing
to
measurement
accuracy.
The
plastic
housing
provides
for
operator
safety
while
measuring
potentially
dangerous
voltages.
600-31.
RF
Probe
83RF
600-32.
The
83RF
converts
the
8050A
into
a high
frequency, 100
kHz
to
100
MHz,
ac voltmeter over a
voltage range of
0.25
V
to
30V
rms.
The
DC
output
of
the
probe
is
calibrated to
be equivalent
to
the
rms
value of
a
sine
wave.
The
probe
is
used with
the
DC
V
function
and
ranges
of the
8050A.
600-33.
RF
Probe
85RF
600-34,
The
85RF
converts the
8050A
into
a high
frequency, iOO
kHz
to
500
MHz,
ac voltmeter over a
voltage range
of
0.25V
to
30V
rms.
The
dc output of
the
probe
is
calibrated to
be
equivalent
to
the
rms
value of a
sine
wave.
The
probe
is
used with
the
DC
V
function
and
ranges of
the
8050A.
600-35.
DC/AC
Current
Probe
Y8100
600-36.
The Model Y8100
DC/
AC
Current Probe
is
a
battery-powered
(four
AA
cells)
Hall-Effect
probe
for
use
with
the
8050A
to
take
dc, ac,
or
composite
(ac
or
dc)
current
measurements,
The damp-on
jaws
on
the
Y8100
allow
it
to
clamp around conductors
up
to
3/4-inch
in
diameter.
The
pistol
shape
allows
safe,
easy,
one-hand
operation
when making
current
measurements.
The
Y8100
has detachable
leads
and
is
used
in
conjunction
with
the voltage inputs of the
8050A.
600-37.
AC
Current Transformer
Y8101
600-38.
TheModelYSIOl
CurrentTransformer(Figure
1)
is
a small
clamp-on
current
transformer designed
to
extend
the current
measuring
capability
of
an
ac current
meter up
to
150A.
A
clamp-on
coil
designed
into
the
probe
allows
measurements
to
be
made
without breaking
the
circuit
under
test.
This
coil
serves as
the
secondary
of a
1:1000 transformer.
The
current-carrying
conductor
being
measured
serves as the
primary.
600-40.
The Model Y8134
Deluxe
Test
Lead
Set
includes
two
probes with sharp
tips,
two
alligator
clips,
two
spade
lugs,
and
a spring-loaded
hook
tip.
Banana
plugs
are recessed
in
an
insulating
shield.
Probes
contain
finger
guards
for
additional protection.
600-41.
Slim-Flex Test
Leads
Y8140
600^2.
The Model Y8140
Test
Lead
Set (Figure
1)
consists of
one
red
and one
black 60-inch
{
1
.52
meter)
test
lead,
each with a standard
banana
plug
on
one end and an
extendible
tip
probe
on
the other
end. This
flexible
metallic
tip
conductor
may
be
extended
up
to
2-1/2
inches,
and
is
insulated
to
within
1
/
1
0 of
an
inch of
its
tip.
This
insulation
reduces
the
chance
of creating
an
inadvertent
short
circuit
while using the
probes
in
their
extended
configuration.
Although
the
Y8140
test
leads
are
intended
for
measuring
voltages,
they
may
also
be
used
for
measuring low
currents.
i
600-4