Page 1
SWIM & SWIM PRO SPAS Cal Spas Home Resorts Owner’s Manual ™...
Page 2
Lloyd’s Material Supply Company, Inc. Lloyd’s Material Supply Company, Inc. Copyright 2023. All rights reserved. Duplication without written consent is strictly prohibited. Lloyd’s Material Supply Company, Inc. Customer Service Department 1462 East Ninth Street Pomona, CA 91766. LTR2023.1146 REV D-4 LTR.2024.1146 Rev A LTR2023.1146, REV.
Important Safety Instructions........Cleaning and Maintenance..........Preparing for Your Swim Spa..........Remove/Replace Jets & Pillows..........Service Access/Foundation Requirements...... Cleaning the Hydro Streamers..........GFCI and Wiring Specification..........Spa Cover Installation.............. Wiring Diagram for USA/Canada......... Draining the Spa................ Filling Up and Inital Power Up..........
Pre-Delivery Checklist � Most cities and counties require permits for Before Delivery □ exterior construction and electrical circuits. Plan your delivery route □ In addition, some communities have codes Choose a suitable location for the spa □ requiring residential barriers such as fencing Lay a 4-6 inch concrete slab □...
Service Area Clearances Service Area Clearances 3 feet / 1 meter 3 feet / 3 feet / 1 meter 1 meter 3 feet / 1 meter Foundation Requirements Foundation Requirements...
One 50 Amp GFCI Four #6 AWG Cop- See Page 10 Breaker per Wires for reference only F-1868DZ Service # 1 Swim Side Four #6 AWG Cop- See Page 10 BP20X One 60 Amp GFCI per Wires for reference only...
TO OUTSIDE OF S YSTEM B OX) TO OUTSIDE OF S YSTEM B OX) The dual zone Olympian swim spa uses both a 240v GFCI connection as illustrated above and an independent 15 Amp 120v outlet. The Spa side of the Olympian uses 120v equipment and internal 15amp GFCI in the power cable.
Filling and Powering Up Your Portable Spa This applies to all spa owners EXCEPT those with the Cal Clarity II bromine generator. See instructions on page 31 for bromine generator operating instructions and spa filling procedures. 1 . Inspect the spa equipment . •...
Page 11
4 . Turn on power to the spa . When the spa is filled to the correct level, turn on the power at the GFCI breaker. (Ensure that the 120V spas are connected to the proper electrical outlet.) 5 . Prime the pump . 6 .
Priming the Pump New spa owners often have difficulty the first time they The pump will not work properly while start their spa and the pump fails to prime. This can be air is trapped in it. Continuing to operate frustrating, but these simple instructions can help you.
Cal Connect RF Set Up Guide Congratuations! Welcome to Cal Connect Control My Spa, the smart control system for spa monitoring on the go. With Cal Connect you will be able to control/monitor water temperture, control pump operation, adjust filtration, and monitor/control any activity occuring within your spa. This Quick Start guide will help you with inital set up of your RF module.
Page 56
Download the Control My Spa App To Begin the inital set up of the Cal Connect system, download the “Control My Spa” app by Balboa Water Group from the App Store or Google Play Store. Before starting the app, have your CMS code in hand. This is a unique code provided to you by your dealer.
Page 57
Control My Spa Set-Up 5- The App will begin scanning for the spas wifi module. within a few seconds the module serial number should appear. 6- Select the “Yes” option once the serial number appears on screen and proceed with the following steps.
Chemical Sanitation Chemical Sanitation produces low chemical odors. Unlike chlorine, it can beak down baceria and other impurities to a safe level with a low burn-out rate.
Factory Filtration Factory Filtration Maintenance Schedule Maintenance Schedule Clean and polish the acrylic surface Clean and treat the spa cover and pillows Troubleshooting Water Clarity Problems Troubleshooting Water Clarity Problems...
Cleaning and Maintenance Cleaning and Maintenance Cleaning and Maintenance Cleaning and Maintenance Removing and Re-seating the Pillows Removing and Re-seating the Pillows Removing and Reseating Pillows Removing and Reseating Pillows Jet Removal and Replacement Jet Removal and Replacement Jet Removal and Replacement Jet Removal and Replacement Cleaning the Hydrostreamers Cleaning the Hydrostreamers...
Cleaning Your Swim Spa Cleaning Your Swim Spa Freedom Sound System Freedom Sound System * Option * Option Aquatic AV Note: *A combination of letters and numbers will follow after the “AquaticAV” name* Aquatic-AV Aquatic-AV... Aquatic-AV... Aquatic-AV... 72 78...
Working Out With Your Swim Spa Working Out With Your Swim Spa Air Injection/ More Resistance Air Injection/ More Resistance Swim Tether Swim Tether Excercise Equipment Excercise Equipment...
Page 77
MFD 3.5” Maxi Flow Directional PLUCS2295091SL PSD 5” Power Storm MED 3” XL Cluster Storm Directional PLUCS2295131SL PLUCS2295031SL mfd 3” Micro Flow Directional PLUCS2295141SL PLUCS2295061SL PST 5” Power Storm Wagon Wheel MM 3” Mini Storm Massage PLUCS2295191SL PLUCS2297061SL-8...
Page 78
Esc., CDG/HLG Part # CS2444049S-CDHL Power Storm Internal, Twister, Velocity Esc. – CDG/HLG Part # CS2444019S-CDHL Pwr. Storm Int. Cal Spas Tri Directional Eyeball, Velocity Esc., Metal CDG/HLG Part # CS2444059S-CDHL Power Storm Internal, Multi-Massage, Velocity Esc., Metal – CDG/HLG...
Page 79
CLUSTER JETS Part # CS2441009S-CDHL Part # S2442059S-CDHL Cluster Storm Internal, Directional, Mini Storm Internal, Multi-Massage, Velocity Esc., Metal – CDG/HLG Velocity Esc., Metal – CDG/HLG Part # CS2441029S-CDHL POLY JETS Cluster Storm Internal, Twin, Velocity Esc., Metal – CDG/HLG Part # CS2443009SSCDHL Poly Storm Internal, Metal...
Page 80
JET INSERTS (Updates) Black Cascade Pillow Carbon Fiber Black “Y” Pillow Carbon Fiber Power Stream Swim Jet Black “Y” Pillow Carbon Fiber Swim Jet Rip Current Metal DSG/clear Power Stream Swim Jet Design S-01-4325 Design S-01-4324 Design S-01-4324 w/ Load Washer...
Page 82
DYNA-FLO PLUS FILTER, 75SF 2"CKV 4SCLP; HIGH VOLUME; LESS CARTRIDGE Part # FIL510-9559-CDCL TELEWEIR FILTER, 50SF 2"CKV 6SCLP LESS CARTRIDGE 2-TONE CDG/HLG Part # FIL510-4609-CDCL 50 sq ft female threaded - antibacterial for Teleweir skimmer shown above) FIL11100208 SUCTION Part # 644-5419CDHL V 5"DESIGNER PRO-SUCT.
Page 83
AIR CONTROL Part # CS6603709-CDHL "Cal Spas 1” Air Control Complete Assembly, Velocity Style, CDG/HLG Part # PLUCS6054309-CDCL "Cal Spas 1” Air Control Complete Assembly, Velocity Style, CDG/HLG" Part # CS6053309-CDHL "Cal Spas 2 ”Top Access Diverter Valve Sub-Assembly, Velocity Style,CDG/HLG“...
Page 88
This warranty begins on the date of delivery of the spa, but in no event later than one year from the date of Manufacture. To obtain service in the event of a defect covered by this Limited Warranty, notify your Cal Spas dealer or Cal manufacture.
Page 89
Cal Spa brand determines that repair of the covered defect is not feasible, it reserves the right the Cal Spas brand determines that repair of the covered defect is not feasible, it reserves the right to provide a to provide a replacement spa of equal or lesser value to the original purchase price.
Page 92
Visit our website www.calspas.com. or scan the QR code or purchase accessories and spare parts at www.quickspaparts.com Lloyd’s Material Supply Company, Inc. LTR.2024.1146 Rev A LTR2023.1146 REV D-4 LTR2023.1146, REV. C-4 1/1/2024 10/19/2023 6/28/2023...