Working Environment; Temperature; Relative Humidity; Altitude - Saluki SMR Series Quick Start Manual

Monitoring receiver module
Table of Contents

Advertisement

Working environment

Temperature

 Ambient temperature during operation:0℃~+50℃
 Storage ambient temperature:-10℃~+50℃

Relative humidity

• When ≥+10℃, humidity ≤95%RH
• When ≥+30℃, humidity ≤75%RH
• When ≥+40℃, humidity ≤45%RH

Altitude

 0~4600 meters
Note: The above three working environment requirements are only for the instrument
operating environment and are not technical indicators.

Ventilation and heat dissipation requirements

In order to ensure that the working environment temperature of the instrument is
within the temperature range required by the working environment, the heat
dissipation space requirements of the instrument should be met:
• The heat dissipation distance at the rear of the instrument is ≥150mm
• The heat dissipation distance between the left and right sides of the instrument is
≥100mm

Static electricity requirements

Please correctly apply the following anti-static measures to reduce electrostatic damage:
• Ensure that all instruments are properly grounded.
• Before connecting the coaxial cable to the instrument, contact the inner and outer
conductors of the cable with the ground for discharge.
• Operators must wear anti-static bracelets or take other anti-static measures before
touching connectors, wires, or assembly operations.
SMR Series Monitoring Receiver Module Quick Start Manual
5 / 11