Mechanical Data

Aluminum Casting
NEMA 4X Protection
NEMA 4X
Cover Seal
Switch Logic Map and
Switch/Cam Arrangement
Switch sequencing data is provided in the table
below to show the change-of-state points during
the rotation of the actuator from CCW to CW
and back again. The red bar shows when that
terminal makes with its respective common.
Switches 1 and 2 are set at the factory and
should NOT be changed. The INCLUDED
auxiliary switches SW3 & SW4 are for terminals
7 thru 12 and those set points may be modifi ed
if need be. When so optioned, SW5 & SW6
auxiliary switches are initially set to function
the same as auxiliary switches SW3 & SW4.
CW
-5 ° 0 °
5 °
85 °
12
Not Open
11
Open Switch Common
10
Open
9
Not Closed
8
Closed Switch Common
7
Closed
P Series Exploded View
Modular
Control
Cards
Mechanical Stop
Screws (2)
CCW
90 ° 95 °
}
SW4 CCW AUX
(Factory Set - Adj)
}
SW3 CW AUX
(Factory Set - Adj)
Used by
Controller
Page 15 of 17 P9/10 HV-N4 Series
(P2/3-120N4 unit is shown)
Epicyclic Gearing
Easily distinguishable
yellow/red position
indicator
Heavy Duty
Drive Motor
Easily accessible
switch & cam stacks
Aluminum Casting
NEMA 4X Protection
Worm Drive
Clutchless