15 Technical data
15.1 Specifications for the ESG-400
Size
Width ............................................................................................................................370 mm
Height ...........................................................................................................................156 mm
Depth ............................................................................................................................465 mm
Volume .....................................................................................................................25752 cm³
Weight ........................................................................................................................... 12.5 kg
Weight of packaging ........................................................................................................ 2.3 kg
Power supply
Voltage range .................................................................... AC 100 to 120 V / AC 220 to 240 V
Frequency .......................................................................................................... 50 Hz / 60 Hz
Maximum input power ................................................................................................ 1500 VA
Fuse (IEC/EN 60127) ...................................................................................... 250 V / T 10 AH
Melting integral (l²t) ................................................................................................. ≥ 13.3 A²s
Breaking capacity .......................................................................................................... ≥ 1500
Compatible fuses: ............................................................................ ESKA No. 522.700 series
Classifications
Protection against electric shock (IEC 60601-1):
Medical electrical equipment ..........................................................................................Class I
Applied parts .............................................................................................................. Type CF
Protection against harmful ingress of water (IEC 60529) .................................................. IPX0
Mode of operation ............................................................................Non-continuous operation
According to Medical Device Regulation (EU) 2017/745 ......................................................IIb
Output
High frequency functions....................................................................... Monopolar and bipolar
High frequency .................................................................................................. 430 kHz ±20%
Maximum HF power ....................................................................................................... 320 W
All modes (except RFCoag) ..............................................................................25% duty cycle
RFCoag (with or without RCAP)......................................................................100% duty cycle
15.2 Ambient conditions for operation, storage and transport
Temperature
For operation .......................................................................... +10 to +40 °C (+50 to +104 °F)
For storage and transport .........................................................-25 to +60 °C (-13 to +140 °F)
Relative humidity
For operation ................................................................................ 30 to 85 %, non-condensing
For storage and transport ............................................................. 10 to 85 %, non-condensing
Schurter SPT 5x20 series
Cooper Bussmann S505 series
(e.g. activated for 10 s, deactivated for 30 s)
Technical data
Littelfuse 215 series
115