This parameter represents the voltage value at which the undervoltage alarm relay will be activated.
It can be edited by short pressing the ENTER key each time to increase the value by 0.1V. This value
must always be lower than the Undervoltage alarm off value.
Now that all parameters are set, the ENTER key must be pressed for two seconds to save the settings
and jump back to the normal operating mode.
3.4

Overview of factory default charge program parameters

Please see the table below for an overview of the main factory default parameter values of each
battery type:
Parameter
Charge Voltage
Absorption Time
Float Voltage
Restart Voltage
Auto Equalize
Charge
Equalize Voltage
Equalize Duration
Temperature
Compensation
Overvoltage
Alarm
Undervoltage
Alarm On Value
Undervoltage
Alarm Off Value
Undervoltage
Alarm Relay On
Value
Undervoltage
Alarm Delay Time
1)
Multiply all voltage values by a factor of 2, 3 or 4 for respectively 24V, 36V and 48V battery
systems
AGM (SLD)
14.6V
120 minutes
120 minutes
13.6V
13.2V
-
-
-
-3mV/°C/cell
-3mV/°C/cell
16.0V
11.6V
12.4V
11.0V
6 seconds
6 seconds
1)
Battery type
GEL
Flooded (FLD)
14.2V
14.4V
120 minutes
13.4V
13.4V
13.2V
13.2V
-
30 days
-
14.8V
-
120 minutes
-3mV/°C/cell
16.0V
16.0V
11.6V
11.6V
12.4V
12.4V
11.0V
11.0V
6 seconds
21
Lithium /
LiFePo4 (LI)
14.4V
-
-
13.2V
-
-
-
-
16.0V
12.0V
12.4V
11.4V
6 seconds