Bosch Professional GWS 18V-7 Original Instructions Manual page 25

Hide thumbs Also See for Professional GWS 18V-7:
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 19
Occasionally clean the ventilation slots on the battery using a
soft brush that is clean and dry.
A significantly reduced operating time after charging indic-
ates that the battery has deteriorated and must be replaced.
Follow the instructions on correct disposal.
Fitting
Fitting Protective Equipment
Remove the battery from the power tool before carry-
u
ing out work on the power tool (e.g. maintenance,
changing tool, etc.). The battery should also be re-
moved for transport and storage. There is risk of injury
from unintentionally pressing the on/off switch.
Note: If the grinding disc breaks during operation or the
holding fixtures on the protective guard/power tool become
damaged, the power tool must be sent to the after-sales ser-
vice immediately; see the "After-Sales Service and Applica-
tion Service" section for addresses.
Protective guard for grinding
Place the protective guard
(9) onto the holder on the
power tool until the coding
cams of the protective guard
are aligned with the holder.
When doing so, press and
hold the unlocking lever (1).
Press the protective guard
(9) onto the spindle collar un-
til the shoulder of the pro-
tective guard is sitting on the
flange of the power tool and
rotate the protective guard
until it audibly clicks into
place.
Adjust the position of the protective guard (9) to meet the
requirements of the operation. To do this, push the unlock-
ing lever (1) upward and rotate the protective guard (9) into
the required position.
Always position the protective guard (9) such that the
u
two cams on the unlocking lever  (1) engage in the
corresponding openings on the protective guard  (9).
Adjust the protective guard (9) such that sparking in
u
the direction of the operator is prevented.
The protective guard (9) must only be adjustable
u
while the unlocking lever (1) is actuated. Otherwise,
the power tool must not be used any more under any
circumstances and must be sent to the after-sales ser-
vice.
Note: The coding cams on the protective guard (9) ensure
that only a protective guard that is suitable for the power
tool can be fitted.
Bosch Power Tools
Protective guard for cutting
For cutting, always use the protective guard for
u
cutting (10) or the protective guard for grinding  (9)
together with the cover for cutting (11).
Provide sufficient dust extraction when cutting stone.
u
The protective guard for cutting (10) is fitted in the same
way as the protective guard for grinding (9).
Metal cover for cutting
Fit the metal cover for cutting (11) on the protective guard
for grinding (9) (see figure A): Swivel the tool retainer back
(➊). Attach the cover (11) to the protective guard for
grinding (9) (➋). Press the tool retainer firmly into place on
the protective guard (9) (➌).
To remove the cover (see figure B), press the button on the
tool retainer (➊) and swivel it back (➋). Remove the
cover (11) from the protective guard (9) (➌).
Plastic cover for cutting
Attach the plastic cover for cutting (11) to the protective
guard for grinding (9) (see figure C). The cover (11) audibly
and visually engages on the protective guard (9).
To remove the cover (see figure D), unlock the cover (11) on
the left- or right-hand side of the protective guard (9) (➊)
and remove the cover (➋).
Extraction guard for cutting with a guide block
The extraction guard for cutting with a guide block (24) is fit-
ted in the same way as the protective guard for grinding (9).
Hand guard
Always fit the hand guard (23) when working with the
u
rubber sanding pad (25) or with the cup brush/conical
brush/diamond annular cutter.
Attach the hand guard (23) to the auxiliary handle (7)/(8).
Standard auxiliary handle/low-vibration auxiliary handle
Screw the auxiliary handle (7)/(8) on the right or left of the
machine head depending on the working method.
Do not operate your power tool without the auxiliary
u
handle (7)/(8).
Do not continue to use the power tool if the auxiliary
u
handle (7)/(8) is damaged. Do not make any altera-
tions to the auxiliary handle (7)/(8).
fortably.
Fitting the Abrasive Tools
Remove the battery from the power tool before carry-
u
ing out work on the power tool (e.g. maintenance,
changing tool, etc.). The battery should also be re-
moved for transport and storage. There is risk of injury
from unintentionally pressing the on/off switch.
Do not touch grinding and cutting discs until they have
u
cooled down. The discs can become very hot while work-
ing.
English | 25
The low-vibration auxiliary
handle (8) reduces vibra-
tion, enabling the tool to be
used safely and more com-
1 609 92A 76N | (30.11.2022)