• 1) SEG4
By SEG4 setting, Minimizing fan operation when thermostat is off.
- Fan operates for 20 seconds at an interval of 5 minutes in heat mode.
- Fan stops or operates Ultra low in Cooling when thermostat is off.
• 2) SEG8
For information on how to connect the external float switch, refer to installation manual of this model.
• 3) SEG15
The external output of SEG15 is generated by MIM-B14 connection. (Refer to the manual of MIM-B14)
• 4) SEG18
If you set the Maximum filter usage time option to a value other than 2 and 6, it is automatically set to 2 (1000 hours).
• 5) SEG20
If you set the Individual control with remote control option to a value other than 0 to 4, it is automatically set to 0 (Indoor 1)
• 6) SEG21
Default value of Heating setting compensation is 9°F(5°C).
Samsung Electronics
SEG14
Use of external control
Indication
Details
0
Disuse
1
On/Off
Sub,
Existing
2
Off
control
Window
3
On/Off
4
Disuse
5
On/Off
Main,
Existing
6
Off
control
Window
7
On/Off
8
Disuse
9
On/Off
Sub,
Reverse
A
Off
control
Window
B
On/Off
C
Disuse
D
On/Off
Main,
Reverse
E
Off
control
Window
F
On/Off
SEG20
Individual control with remote
control
5
Indication
Details
0 or 1
Indoor1
2
Indoor2
3
Indoor3
4
Indoor4
SEG15
Setting the output of
extermal control
3)
Indication
Details
0
Thermo on
Reserved
1
Operation On
SEG21
Heating setting compensation
6
Indication
Details
0
Default
1
3.6˚F(2˚C)
2
9˚F(5˚C)
SEG16
SEG17
Buzzer control
Indication
Details
Use of
0
buzzer
Disuse of
1
buzzer
SEG22
SEG23
Reserved
Reserved
Troubleshooting
SEG18
Maximum filter usage
time
4)
Indication
Details
1000
2
hours
2000
6
hours
SEG24
Reserved
4-25