7.2 Electrical connection of external dosing system

The power supply to the external dosing system must never be connected to the machine's incoming terminal
block or to the edge connectors on the I/O-board.
7.2.1

Machine with connectors

Connect the external dosing system to connections A and B on the machine.
Connect the signal cable to B and the power supply to A.
For Efficient dosing system the cables are delivered with the machine.
Connect the power supply cable to the machine A and the other end of the cable together with the cable from Effi-
cient Dosing in a connection box or with plug and receptacle.
Connect one end of the cable to the Efficient Dosing Controller J2 and the other end to the machine B.
1
3
4
3
6
9
A
1
Line
2
Neutral
3
4
Ground
Installation manual
A
2
2
B
1
4
7
5
1
2
3
4
5
6
7
8
9
Connection box
B
Neutral
Program run
Gnd
Signal 2
Signal 3
Signal 4
Signal 5
Rx
Tx
Pump unit
Controller
J1 RJ11 J2