SIGLENT TECHNOLOGIES SDS3000X HD Series Quick Start Manual

SIGLENT TECHNOLOGIES SDS3000X HD Series Quick Start Manual

Digital storage oscilloscope

Advertisement

Quick Links

SDS3000X HD
Series
Digital Storage
Oscilloscope
Quick Start
EN01A

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SDS3000X HD Series and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for SIGLENT TECHNOLOGIES SDS3000X HD Series

  • Page 1 SDS3000X HD Series Digital Storage Oscilloscope Quick Start EN01A...
  • Page 3: Copyright Information

    Information in this publication replaces all previously corresponding material. Any method of copying, extracting or translating the contents of this manual is not allowed without the permission of SIGLENT. Note: SIGLENT is the registered trademark of SIGLENT TECHNOLOGIES CO., SDS3000X HD Quick Start...
  • Page 4: Table Of Contents

    Contents Copyright Information ..................... 1 General Safety Summary ..................3 Safety Terms and Symbols ..................4 General Care and Cleaning ..................5 General Inspection....................6 Quick Start ......................7 Front of Oscilloscope .................... 10 Back of Oscilloscope .................... 11 Probe Compensation .................... 12 User Interface .......................
  • Page 5: General Safety Summary

    General Safety Summary Carefully read the following safety precautions to avoid any personal injury or damage to the instrument and any products connected to it. To avoid potential hazards, please use the instrument as specified. Use Proper Power Cord Only the power cord designed for the instrument and authorized by local government regulations should be used.
  • Page 6: Safety Terms And Symbols

    Avoid Exposed Circuits and Components Do not touch exposed contacts or components when the instrument's power is on. Use Only the Specified Fuse Do Not Operate Without Covers Do not operate the instrument with covers or panels removed. Safety Terms and Symbols Terms used in this product.
  • Page 7: General Care And Cleaning

    General Care and Cleaning Care Do not store or leave the instrument in direct sunshine for extended periods of time. To avoid damages to the instrument or probes, please do not expose them to fog, liquid, or solvents. Cleaning Please perform the following steps to clean the instrument and probes regularly in accordance with its operating conditions.
  • Page 8: General Inspection

    General Inspection 1. Inspect the shipping container Keep the damaged shipping container or cushioning material until the contents of the shipment have been completely checked and the instrument has passed both electrical and mechanical tests. The consigner or carrier will be responsible for damages to the instrument resulting from shipment.
  • Page 9: Quick Start

    Quick Start Mechanical Dimension SDS3000X HD Quick Start...
  • Page 10 Adjust the Supporting Legs Adjust the supporting legs properly to use them as stands to tilt the oscilloscope upwards for stable placement as well as easier operation and observation of the instrument. Connecting to Power Supply The standard power supply for the instrument is 100~240 V, 50/60 Hz. Please use the power cord provided with the instrument to connect it to AC power.
  • Page 11 Connect to a LAN Connect the 1000M LAN port to the LAN using a cable Perform Utility > Menu > I/O > LAN Config , or click the icon in the lower right corner of the display to set the LAN.
  • Page 12: Front Of Oscilloscope

    Front of Oscilloscope Touch Screen Display The USB 3.0 Host Ports Connect display and major functions to USB storage devices for area. See "User Interface" data transfer or USB mouse/ for more details keyboard for control Front Panel Includes knobs Digital Input Connector and buttons.
  • Page 13: Back Of Oscilloscope

    Back of Oscilloscope Ext Trigger Input USB 3.0 Device Connects with a PC for remote control Auxiliary Out Outputs the USB 2.0 Host Connect with a trigger indicator. When Mask USB storage device or USB Test is enabled, outputs the mouse/keyboard pass / fail signal AC Power Input...
  • Page 14: Probe Compensation

    Probe Compensation All oscilloscope probes should be properly compensated before their first use with the oscilloscope. A non-compensated or inadequately compensated probe may cause inaccurate measurement. The following steps illustrate the proper probe compensation procedure. Use the probe to connect the C1 Input Terminal and the Compensation Signal Output Terminal on the front panel.
  • Page 15: User Interface

    User Interface Menu Bar Grid Area displays the waveform traces. Traces can be moved by dragging them and re-scaled by pinch and spread Channel descriptor boxes include analog channels (C1-C4), digital channels (D), math (F1-F4) and Memory (M1-M4). They show the parameters of the corresponding traces.
  • Page 16 Channel Descriptor Box Channel Index Bandwidth Information Coupling and Input Impedance Vertical Scale Vertical Offset Probe Attenuation Factor Timebase and Trigger Descriptor Boxes Trigger delay Horizontal scale (timebase) Samples Sample Rate Trigger source Trigger coupling Trigger mode Trigger level Trigger type Trigger slope SDS3000X HD Quick Start...
  • Page 17 Dialog Box The dialog box on the right side of the screen is the main area for setting the parameters of the selected function. Title bar. Touching the bar can hide the dialog box, and touching again can open the dialog box Parameter setting area Scroll bar.
  • Page 18 To Set Parameters Several different ways are provided to set parameters: Switch -- sets parameters with two states, such as to enable or disable a function. Touch the switch region to change from one state to the other. List -- sets parameters with more than two options, such as the coupling mode of channels.
  • Page 19 Touch Gestures Waveforms, cursors and trigger level can be adjusted by touch gestures in the grid area. Drag the waveform left and right to move it on the horizontal axis Pinch and spread the waveform horizontally to re-scale the timebase Drag the waveform up and down to move it on the vertical axis Pinch and spread the waveform...
  • Page 20 Touch and drag the cursor to move it Touch drag cursor information region to move the pair of cursors simultaneously Draw a rectangular box to create a zone or a histogram region. At the beginning of the gesture keep the angle close to 45°...
  • Page 21 Front Panel The front panel is designed to operate the basic functions without having to open the software menu. Most of the front panel controls duplicate functionality available through the touch screen display but the operation is more quickly achieved Automatically sets the waveform to adapt the display according to its frequency and amplitude...
  • Page 22: Basic Operations

    Basic Operations Turn On / Disable a Channel From the Front Panel Push the channel button ( 1-4, Digital, Math, Memory ) to turn on the corresponding channel. Its channel descriptor box and dialog box will appear on the display. If a channel is already on but not activated, push the button to activate it.
  • Page 23 Channel Setup Touch the channel descriptor box, a quick dialog will pop up. Vertical scale and offset can also be set from this dialog box. Touch the region to set the vertical scale with the universal knob or virtual keypad ▲...
  • Page 24 Activating a channel in the quick dialog of the channel recalls the channel dialog box, displaying more parameters: Turn channel on/off Coupling ( DC, AC or GND ) Bandwidth limit ( Full, 200 MHz or 20 MHz ) Probe attenuation ( 1X, 10X, 100X or custom ) Set the label text.
  • Page 25 Horizontal System Rotate to adjust the horizontal scale ( time / div ); When Zoom is enabled, push to switch between the main window and zoom window Push to enable / disable Zoom Push to enable horizontal Roll; push again to exit Roll mode.
  • Page 26 Acquisition System Touch on the quick menu of the timebase settings, or touch the menu bar Acquire > Menu to recall the Acquire dialog box on the right side. Select the interpolation mode Select the Acq mode Select the acquisition mode ( Normal / Peak / Average / ERES ) Select the Memory Management mode ( Auto, Fixed Sample Rate, and Fixed...
  • Page 27 Zoom Waveform zoom in the horizontal and vertical directions is supported. Push the button on the front panel to enable Zoom mode When the Zoom mode is enabled, press down the horizontal knob to switch between the main window and zoom window. Currently activated window is high-lighted by dash line.
  • Page 28 Trigger The trigger system supports multiple powerful triggering modes including serial bus triggering. Refer to the User Manual for more details. Opens trigger setup dialog box Auto mode -- triggers after preset period if no valid trigger occurs Single-mode -- triggers once when all conditions are met Normal mode -- triggers repeatedly when all conditions are met...
  • Page 29 Select trigger type Select the trigger source Select the trigger slope ( When the trigger type is "Edge", "Slope" and other specific types ) Set holdoff ( None / Time / Events ) Set trigger coupling mode ( DC / AC / LF Reject / HF Reject ) Enable / disable Noise Rejection.
  • Page 30 Math Touch + > Fx , or push the button on the front panel to create a math trace and open math setup dialog box Math trace Math setup dialog box Selects the trace (F1 ~ F4) Selects the operator and source (C1~C4, Z1~Z4, F1~F4) SDS3000X HD Quick Start...
  • Page 31 Measure & Statistics Touch Measure > Menu , or push the button on the front panel to open measure setup dialog box Measurement parameters and statistics display area. If select the mode as “Simple”, the "Simple" parameter area is displayed. Touch the button on the front panel to reset the statistics Set the mode of measure: Simple or Advanced.
  • Page 32 Cursors Cursors set measurement points on the Vertical or Horizontal axis of a trace (or both). For more information please refer to the User Manual. Push the button to open the cursors setup dialog box Rotate the knob to move the selected cursor; push to select different cursor The display mode of cursors Following...
  • Page 33 Memory Memory waveforms ( M1, M2, M3, and M4 ) are analog or math traces stored in the non-volatile memory. They can be recalled to the display for comparison with other traces. Press the button on the front panel to set the Memory waveforms. Select the location of the memory (M1 ~ M4) Select the source (Cx / Zx / Fx / Mx / File) Import the trace of the selected source in...
  • Page 34 Save/Recall Touch Utility > Save/Recall to save / recall a setup, picture, waveform data or reference waveform. Choose Save or Recall operation Select the object type Display mode of the save path tips Recall the File Manager for further operations File Manager Quickly Save Push the...
  • Page 35 Quick Action Push the button on the front panel to perform a specified action. Touch Utility > Quick Action to open the Quick Action menu and set the action mapping to the button. By default, Quick Action is disabled, and pushing the button for the first time will open the Quick Action menu.
  • Page 36 Headquarters: SIGLENT Technologies Co., Ltd Add: Bldg No.4 & No.5, Antongda Industrial Zone, 3rd Liuxian Road, Bao'an District, Shenzhen, 518101, China Tel: + 86 755 3688 7876 Fax: + 86 755 3359 1582 Email: sales@siglent.com Website: int.siglent.com North America: SIGLENT Technologies America, Inc...

Table of Contents