SDS1000X-E User Manual
SDS1000X-E Series
Digital Oscilloscope
User Manual
UM0101E-E03C

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SDS1000X-E Series and is the answer not in the manual?

Questions and answers

Summary of Contents for SIGLENT TECHNOLOGIES SDS1000X-E Series

  • Page 1 SDS1000X-E User Manual SDS1000X-E Series Digital Oscilloscope User Manual UM0101E-E03C...
  • Page 2 Copyright SIGLENT TECHNOLOGIES CO., LTD. All Rights Reserved. Trademark Information SIGLENT is the registered trademark of SIGLENT TECHNOLOGIES CO., LTD. Declaration SIGLENT products are protected by patent law in and outside of P.R.C. SIGLENT reserves the right to modify or change parts of or all the specifications or pricing policies at company’s sole decision.
  • Page 3 SDS1000X-E User Manual Safety Information General Safety Summary Carefully read the following safety precautions to avoid any personal injury or damage to the instrument and any products connected to it. To avoid potential hazards, please use the instrument as specified. Use Proper Power Line Only the power cord designed for the instrument and authorized by local country could be used.
  • Page 4 SDS1000X-E User Manual Use only the specified fuse. Do Not Operate Without Covers Do not operate the instrument with covers or panels removed. Do Not Operate With Suspected Failures. If you suspect damage occurs to the instrument, have it inspected by qualified service personnel before further operations.
  • Page 5: Safety Terms And Symbols

    SDS1000X-E User Manual Safety Terms and Symbols Terms in this Manual. These terms may appear in this manual: WARNING Warning statements indicate the conditions or practices that could result in injury or loss of life. CAUTION Caution statements indicate the conditions or practices that could result in damage to this product or other property.
  • Page 6: Measurement Category

    SDS1000X-E User Manual Measurement Category Measurement Categories This oscilloscope can make measurements in other circuits that are not directly connected to mains. WARNING This oscilloscope can only be used for measurements within its specified measurement categories. Not to use the product for measurements within other measurement categories, such as CAT II, CAT III, CAT IV.
  • Page 7: Working Environment

    SDS1000X-E User Manual Working Environment Temperature Operating: 10℃ to +40℃ Non-operation:-20℃ to +70℃ Humidity Under +35℃:≤90% relative humidity +35℃ to +40℃: ≤60% relative humidity WARNING To avoid short circuit inside the instrument or electric shock, please do not operate in humid environment.
  • Page 8: General Care And Cleaning

    SDS1000X-E User Manual areas are free from obstructions and have free air. When using the oscilloscope in a bench-top or rack setting, provide at least 10 cm clearance beside, above and behind the instrument for adequate ventilation. WARNING Inadequate ventilation may cause temperature increase which would damage the instrument.
  • Page 9: L'information De Sûreté

    SDS1000X-E User Manual L'information de sûreté Résumé général de sûreté Lisez soigneusement les mesures de sécurité suivantes pour éviter n'importe quelles blessures ou les dommages à l'instrument et à tous les produits se sont reliés à eux. Pour éviter des risques, utilisez svp l'instrument comme indiqué.
  • Page 10 SDS1000X-E User Manual de fusible seulement le fusible indiqué. Ne fonctionnez pas sans couvertures n'actionnent pas l'instrument des couvertures ou des panneaux étant coupés. Ne fonctionnez pas avec des échecs suspectés. Si vous suspectez les dommages se produisent à l'instrument, l'ont inspecté par le personnel de service qualifié...
  • Page 11: Limites Et Symboles De Sûreté

    SDS1000X-E User Manual Limites et symboles de sûreté Limites en ce manuel. Ces limites peuvent apparaître en ce manuel : Les rapports d'avertissement D'AVERTISSEMENT indiquent les conditions ou les pratiques qui pourraient avoir comme conséquence les dommages ou la perte de la ie. Les rapports d'attention d'ATTENTION indiquent les conditions ou les pratiques qui pourraient avoir comme consequence...
  • Page 12: Catégorie De Mesure

    SDS1000X-E User Manual Catégorie de mesure Les oscilloscopes peuvent faire des mesures dans d'autres circuits qui ne sont pas directement reliés aux forces. Pour ne pas employer le produit pour des mesures dans d'autres catégories de mesure, telles que le CAT II, CAT III, CAT IV. Ne pas utiliser l'équipement pour des mesures sur des forces circuite, pour ne pas utiliser l'équipement pour des mesures sur la tension excèdent la gamme de tension décrivent dans le manuel.
  • Page 13: Environnement De Fonctionnement

    SDS1000X-E User Manual Environnement de fonctionnement Opération de la température : 10℃ au non-fonctionnement de +40℃ : - 20℃ à l'humidité de +70℃ sous +35℃ : humidité relative +35℃ de ≤90% à +40℃ : humidité relative de ≤60% EN AVERTISSANT d'éviter le court-circuit à...
  • Page 14: Condition De Ventilation

    SDS1000X-E User Manual Condition de ventilation This oscilloscope uses fan to force cooling. Please make sure that the air intake and exhaust areas are free from obstructions and have free air. When using the oscilloscope in a bench-top or rack setting, provide at least 10 cm clearance beside, above and behind the instrument for adequate ventilation.
  • Page 15: Soin Général Et Nettoyage

    SDS1000X-E User Manual Soin général et nettoyage Ne stockez pas ou ne laissez pas l'instrument en soleil direct pendant de longues périodes. Pour éviter d'endommager l'instrument, svp ne les laissez pas dans le brouillard, le liquide, ou le dissolvant. nettoyage Veuillez exécuter les étapes suivantes pour nettoyer l'instrument régulièrement selon ses conditions de fonctionnement.
  • Page 16: Document Overview

    SDS1000X-E User Manual Document Overview This manual introduces how to use the digital oscilloscope in details. Quick Start Provide information about preparations before using the instrument and a brief introduction of the instrument. Vertical System Introduce the functions of the vertical system of the oscilloscope.
  • Page 17: Table Of Contents

    SDS1000X-E User Manual Table of Content Copyright and Declaration ....................I Safety Information ........................ II General Safety Summary ..................... II Safety Terms and Symbols ..................IV Measurement Category ....................V Working Environment ....................VI Ventilation Requirement ..................... VI General Care and Cleaning ..................VII L'information de sûreté...
  • Page 18 SDS1000X-E User Manual Coupling ........................28 Bandwidth Limit ......................29 Probe .......................... 29 Input Impedance ......................30 Unit ..........................30 Deskew ........................30 Invert ........................... 31 Trace Visible/Hidden ....................31 Horizontal System ......................32 Horizontal Scale ......................33 Trigger Delay ......................34 Roll Mode ........................
  • Page 19 SDS1000X-E User Manual Runt Trigger ......................82 Pattern Trigger ....................84 Serial Trigger and Decode ....................86 I2C Trigger and Serial Decode ................... 87 Setup for I2C Signals ..................87 I2C Trigger ......................88 I2C Serial Decode ....................91 SPI Trigger and Serial Decode................... 92 Setup for SPI Signals ..................
  • Page 20 SDS1000X-E User Manual Automatic Measurement ..................137 All Measurement ....................... 139 Gate Measurement ....................140 Clear Measurement ....................140 Display ..........................141 Display Type ......................142 Color Display ......................143 Persistence ....................... 144 Clear Display ......................145 Grid Type ........................145 Intensity ........................
  • Page 21 SDS1000X-E User Manual Output ........................ 175 Wave ......................... 175 Setting ....................... 177 Systems ......................178 Remove Device ....................180 IO Set ........................181 USB Device ....................... 181 LAN ........................181 WLAN ........................ 182 Web Server ....................... 184 Update Firmware and Configuration ................ 185 Do Self-Test ......................
  • Page 22 SDS1000X-E User Manual Content of Figure Figure 1 Front View (2-channel scope) ................ 3 Figure 2 Top View (2-channel scope) ................3 Figure 3 Front View (4-channel scope) ................ 4 Figure 4 Top View (4-channel scope) ................4 Figure 5 Adjust the Supporting Legs ................5 Figure 6 To Connect to Power Supply .................
  • Page 23 SDS1000X-E User Manual Figure 39 I2C DECODE Menu ................... 87 Figure 40 I2C SIGNALLE Menu ................. 87 Figure 41 I2C TRIGGER Menu .................. 90 Figure 42 I2C Decode Bus Display ................91 Figure 43 I2C Decode List Display ................91 Figure 44 SINGAL Menu ....................
  • Page 24 SDS1000X-E User Manual Figure 83 Measure Pulse Width ................131 Figure 84 Voltage Measurements ................133 Figure 85 Overshoot ....................134 Figure 86 Preshoot ....................134 Figure 87 Time Measurements ................135 Figure 88 Select the Measurement Parameter ............137 Figure 89 Added the Measurement ................
  • Page 25 SDS1000X-E User Manual Figure 127 BODE PLOT II Menu................193 Figure 128 CONFIGURE Menu................193 Figure 129 VARI-LEVEL Menu ................194 Figure 130 DISPLAY Menu ..................195 Figure 131 DATA Menu .................... 196 Figure 132 Bode Plot List On ................... 196 Figure 133 Bode Plot Interface Connection .............
  • Page 26: Quick Start

    SDS1000X-E User Manual Quick Start This chapter introduces the preparations when using the oscilloscope for the first time, the front panel, rear panel and user interface of the oscilloscope. The contents of this chapter:  General Inspection  Appearance and Dimensions ...
  • Page 27: General Inspection

    SDS1000X-E User Manual General Inspection Inspect the shipping container for damage. Keep the damaged shipping container or cushioning material until the contents of the shipment have been checked for completeness and the instrument has passed both electrical and mechanical tests. The consigner or carrier shall be liable for the damage to instrument resulting from shipment.
  • Page 28: Appearance And Dimensions

    SDS1000X-E User Manual Appearance and Dimensions Figure 1 Front View (2-channel scope) Figure 2 Top View (2-channel scope) WWW.SIGLENT.COM...
  • Page 29 SDS1000X-E User Manual Figure 3 Front View (4-channel scope) Figure 4 Top View (4-channel scope) WWW.SIGLENT.COM...
  • Page 30: Prepare For Using

    SDS1000X-E User Manual Prepare for Using Adjust the Supporting Legs Adjust the supporting legs properly to use them as stands to tilt the oscilloscope upwards for stable placement of the oscilloscope as well as better operation and observation. Figure 5 Adjust the Supporting Legs Connect the Power Supply The power requirements of the oscilloscope are 100-240 V, 50/60Hz or 100-120 V, 400Hz.
  • Page 31: Power-On Inspection

    SDS1000X-E User Manual 2-channel scope 4-channel scope Figure 6 To Connect to Power Supply Power-on Inspection When the oscilloscope is energized, press the power key at the lower-left corner of the front panel to start the oscilloscope. During the start-up process, the oscilloscope performs a series of self-tests and you can hear the sound of relay switching.
  • Page 32: Probe Compensation

    SDS1000X-E User Manual 4-channel scope Use the probe to connect the input terminal of CH1 of the oscilloscope and the “Compensation Signal Output Terminal” of the probe. Press the Auto Setup. Observe the waveform on the display. In normal condition, the display should be a square waveform as shown in the figure below: Figure 7 Function Inspection Use the same method to test the other channels.
  • Page 33 SDS1000X-E User Manual follows. Set the switch to 10X on the probe. Perform steps 1, 2, 3 and 4 of “Function Inspection” in the previous section. Check the waveforms displayed and compare them with the following: Under Perfectly Over Compensated Compensated Compensated Use a nonmetallic driver to adjust the low-frequency compensation adjustment hole...
  • Page 34: Front Panel Overview

    SDS1000X-E User Manual Front Panel Overview Figure 8 2-channel Scope Front Panel Overview NO. Description NO. Description LCD Display Vertical Control Probe Compensation/ Ground Universal Knob Terminal Common Function Menus Analog Channel and Ext Input Run/Stop USB Host Auto Setup Menu Softkey Trigger Control Menu on/off...
  • Page 35 SDS1000X-E User Manual Figure 9 4-Channel Scope Front Panel Overview NO. Description NO. Description LCD Display Horizontal Control Universal Knob Trigger Control Common Function Menus Menu on/off Clear Sweeps Menu Softkey Run/Stop One- Button shortcut for Save Decode Analog Channel Auto Setup Power Button Navigate...
  • Page 36: Rear Panel Overview

    SDS1000X-E User Manual Rear Panel Overview Figure 10 2-Channel Scope Rear panel Overview Handle Pull up the handle vertically for easy carrying of the instrument. When you do not need the handle, press it down. Safety lock Hole You can lock the instrument to a fixed location using the security lock (please buy it yourself) via the lock hole.
  • Page 37 SDS1000X-E User Manual Figure 11 4-channel Scope Rear panel Overview Handle Pull up the handle vertically for easy carrying of the instrument. When you do not need the handle, press it down. The instrument can be connected to network via this interface to perform remote control.
  • Page 38: Front Panel Function Overview

    SDS1000X-E User Manual Front Panel Function Overview Horizontal 4-channel scope 2-channel scope : Quickly enter the roll mode. The timebase range is from 50mS/div to 100S/div. : Enable or disable search function. This function can search for the events that users specify in the acquired data, the results are displayed with white triangle symbol.
  • Page 39: Vertical

    SDS1000X-E User Manual Vertical 2-channel scope 4-channel scope : Analog input channels. The two channels are marked by different colors which are also used to mark both the corresponding waveforms on the screen and the channel input connectors. Vertical Position Knob : adjust the vertical position of the current channel waveform.
  • Page 40: Trigger

    SDS1000X-E User Manual Trigger 2-channel scope 4-channel scope : press the button to enter the TRIGGER function menu. The oscilloscope provides abundant advanced trigger functions : press the button to set the trigger mode to Auto. : press the button to set the trigger mode to Normal. : press the button to set the trigger mode to Single.
  • Page 41: Run Control

    SDS1000X-E User Manual Run Control : press this key to enable the waveform auto setting function. The oscilloscope will automatically adjust the vertical scale, horizontal time base and trigger mode according to the input signal to realize optimum waveform display. : press the button to set the acquisition state to Run or Stop.
  • Page 42: Universal Knob

    SDS1000X-E User Manual Universal Knob Adjust the waveform intensity. You can press the Display/Persist button; press the Next Page softkey to go to the second page of the DISPLAY function menu; press the Intensity softkey and then turn the Universal Knob to adjust the waveform intensity. Select the desired submenu.
  • Page 43: Menu

    SDS1000X-E User Manual Menu 2-channel scope common function panel 4-channel scope common function panel : Press to enter the CURSOR function menu. The oscilloscope provides manual and track cursor mode. : Press to enter the DISPLAY function menu and quickly enable the persist function.
  • Page 44 SDS1000X-E User Manual : Press the button to enter the SAVE/RECALL function menu to save setups, waveforms, pictures, or CSV files, binary data, matlab files, and default key presets to internal memory or USB flash driver. : Press the button to reset the oscilloscope to user default setup. : Press the button to enter the history mode.
  • Page 45: Help

    SDS1000X-E User Manual Help The oscilloscope has an on line help function that supplies multi-language help information. You can access the help function by pressing any button for 2 seconds and a help window will explain the function. Also all of the submenus include help information. Figure 12 Help Message WWW.SIGLENT.COM...
  • Page 46: User Interface

    User Interface Figure 13 User Interface Product Logo SIGLENT is the registered trademark of SIGLENT TECHNOLOGIES CO., LTD. Channel Label/Waveform Different channels are marked by different colors and the color of the waveform complies with the color of the channel.
  • Page 47 SDS1000X-E User Manual Indicate the trigger delay on the waveform. Frequency Counter Display the frequency value of the trigger channel. Sampling Rate/ Memory Depth Display the current sampling rate and memory depth. Sa means the current sampling rate and Curr means the current memory depth. Trigger Setup Trigger Type : display the current trigger type.
  • Page 48 SDS1000X-E User Manual 13. Menu Display the corresponding function menu of the selected button. Press the corresponding softkey to set the oscilloscope. WWW.SIGLENT.COM...
  • Page 49: Security Lock

    SDS1000X-E User Manual Security Lock If needed, you can use the security lock (please buy it yourself) to lock the oscilloscope to a fixed location. The method is as follows, align the lock with the lock hole and plug it into the lock hole vertically, turn the key clockwise to lock the oscilloscope and then pull the key out.
  • Page 50: Vertical System

    SDS1000X-E User Manual Vertical System This chapter introduces how to set the vertical system of the oscilloscope. The contents of this chapter:  Enable the Channel  Adjust Scale  Vertical Position  Coupling  Bandwidth Limit  Probe  Input Impedance ...
  • Page 51: Enable The Channel

    SDS1000X-E User Manual Enable the Channel The oscilloscope provides 2/4analog input channels and provides independent vertical control system for each channel. As the vertical system setting methods of every channel is the same, this chapter takes CH1 as an example to introduce the setting method of the vertical system.
  • Page 52: Adjust Scale

    SDS1000X-E User Manual Adjust Scale The vertical scale can be adjusted in Coarse or Fine mode. Coarse adjustment (take counterclockwise as an example): set the vertical scale in  1-2-5 step namely 500uV/div, 1 mV/div, 2 mV/div, 5 mV/div, 10 mV/div …10 V/div. Fine adjustment: further adjust the vertical scale within a relatively smaller range to improve vertical resolution.
  • Page 53: Vertical Position

    SDS1000X-E User Manual Vertical Position Turn the VERTICAL Position Knob to adjust the vertical position of the channel waveform. Turn the knob clockwise to increase the vertical position and the channel waveform moves up while counterclockwise to reduce the vertical position and the waveform moves down.
  • Page 54: Bandwidth Limit

    SDS1000X-E User Manual Bandwidth Limit Set the bandwidth limit to reduce display noise. For example, the signal under test is a pulse with high frequency oscillation. When the bandwidth limit set to Full, the high frequency components of the signal ...
  • Page 55: Input Impedance

    SDS1000X-E User Manual 10000X 10000 : 1 Input Impedance The channel input impedance is 1MΩ. Impedance setting to 1MΩ is for use with many passive probes and for general-  purpose measurements. The higher impedance minimizes the loading effect of the oscilloscope on the device under test.
  • Page 56: Invert

    SDS1000X-E User Manual Invert When Invert is set to On, the voltage values of the displayed waveform are inverted. Invert affects how a channel is displayed and it keeps the trigger settings. Inverting a channel also changes the result of any math function selected and measure function.
  • Page 57: Horizontal System

    SDS1000X-E User Manual Horizontal System This chapter introduces how to set the horizontal system of the oscilloscope. The contents of this chapter:  Horizontal Scale  Trigger Delay  Roll Mode  Zoom Mode WWW.SIGLENT.COM...
  • Page 58: Horizontal Scale

    SDS1000X-E User Manual Horizontal Scale Turn the HORIZONTAL Scale Knob on the front panel to adjust the horizontal time base. Turn clockwise to reduce the horizontal time base and turn counterclockwise to increase. The time base information at the upper left corner of the screen will change accordingly during the adjustment.
  • Page 59: Trigger Delay

    SDS1000X-E User Manual Trigger Delay Turn the Position Knob on the front panel to adjust the trigger delay of the waveform. During the modification, waveforms of all the channels would move left or right and the trigger delay message at the upper-right corner of the screen would change accordingly. Press down this knob to quickly reset the trigger delay.
  • Page 60: Roll Mode

    SDS1000X-E User Manual Roll Mode Press the Roll button to enter the roll mode. In Roll mode the waveform moves slowly across the screen from right to left. It only operates on time base settings of 50 ms/div and slower. If the current time base setting is faster than the 50 ms/div limit, it will be set to 50 ms/div when Roll mode is entered.
  • Page 61: Zoom Mode

    SDS1000X-E User Manual Zoom Mode Zoom is a horizontally expanded version of the normal display. You can use Zoom to locate and horizontally expand part of the normal window for a more detailed (higher- resolution) analysis of signals. Press the HORIZONTAL Scale Knob on the front panel to turn on the zoom function, and press the button again to turn off the function.
  • Page 62 SDS1000X-E User Manual you're looking at the waveform after the trigger event. To change the time base of the normal window, turn off Zoom; then, turn the Horizontal Scale Knob. WWW.SIGLENT.COM...
  • Page 63: Sample System

    SDS1000X-E User Manual Sample System This chapter introduces how to use the run control and set the sampling system of the oscilloscope. The contents of this chapter:  Run Control  Overview  Memory Depth  Sampling Mode  Interpolation Method ...
  • Page 64: Run Control

    SDS1000X-E User Manual Run Control Press the Run/Stop or Single button on the front panel to run or stop the sampling system of the scope. When the Run/Stop b is green, the oscilloscope is running, that is, acquiring data  when trigger conditions are met.
  • Page 65: Overview

    SDS1000X-E User Manual Overview To understand the oscilloscope's sampling and acquisition modes, it is helpful to understand sampling theory, sample rate and oscilloscope bandwidth and sample rate. Sampling Theory The Nyquist sampling theorem states that for a limited bandwidth (band- limited) signal with maximum frequency f , the equally spaced sampling frequency f must be greater...
  • Page 66: Bandwidth And Sample Rate

    SDS1000X-E User Manual frequency (Nyquist Frequency), the frequency of the waveform rebuilt from the sample data is lower than the actual signal frequency. The most common aliasing is the jitter on fast edge. Waveform Leakage: when the sample rate is too low, the waveform rebuilt from the sample data does not reflect all the actual signal information.
  • Page 67 SDS1000X-E User Manual However, digital signals have frequency components above the fundamental frequency (square waves are made up of sine waves at the fundamental frequency and an infinite number of odd harmonics), and typically, for 500 MHz bandwidths and below, oscilloscopes have a Gaussian frequency response.
  • Page 68: Memory Depth

    SDS1000X-E User Manual Memory Depth Memory depth refers to the number of waveform points that the oscilloscope can store in a single trigger sample and it reflects the storage ability of the sample memory. The oscilloscope provides up to 14 Mpts memory depth. Press the Acquire button on the front panel;...
  • Page 69 SDS1000X-E User Manual uses the interpolation method to display a waveform. Interpolation method is a processing method to “connect all the sampling points”, and using some points to calculate the whole appearance of the waveform. For real-time sampling interpolation method is used, even if the oscilloscope in a single captures only a small number of sampling points.
  • Page 70 SDS1000X-E User Manual Figure 17 x Interpolation Figure 18 Sinx/x Interpolation WWW.SIGLENT.COM...
  • Page 71: Acquisition Mode

    SDS1000X-E User Manual Acquisition Mode The acquisition mode is used to control how to generate waveform points from sample points. The oscilloscope provides the following acquisition mode: Normal, Peak Detect, Average and Eres. Press the Acquire button on the front panel to enter the ACQUIRE function menu; Press the Acquisition softkey;...
  • Page 72 SDS1000X-E User Manual within the sample interval to get the envelope of the signal or the narrow pulse of the signal that might be lost. In this mode, signal confusion can be prevented but the noise displayed would be larger. In this mode, the oscilloscope can display all the pulses with pulse widths at least as wide as the sample period.
  • Page 73: Average

    SDS1000X-E User Manual Average In this mode, the oscilloscope averages the waveforms from multiple samples to reduce the random noise of the input signal and improve the vertical resolution. The greater the number of averages is, the lower the noise will be and the higher the vertical resolution will be but the slower the response of the displayed waveform to the waveform changes will The available range of averages is from 4 to 1024 and the default is 16.
  • Page 74: Eres

    SDS1000X-E User Manual Figure 23 With Random Noise, Average Mode Eres This mode uses a kind of ultra-sample technique to average the neighboring points of the sample waveform to reduce the random noise on the input signal and generate much smoother waveforms on the screen.
  • Page 75: Horizontal Format

    SDS1000X-E User Manual Horizontal Format Press the Acquire button on the front panel; then press the XY soft key to set the XY(On) or YT(Off) mode. The default setup is YT. It is the normal viewing mode for the oscilloscope. In the Normal time mode, signal events occurring before the trigger are plotted to the left of the trigger point and signal events after the trigger plotted to the right of the trigger point.
  • Page 76 SDS1000X-E User Manual obtained should be within quadrant I and IV, namely within (0 to π/2) or (3π/2 to 2π). If the principal axis of the ellipse is within quadrant II and IV, the phase deviation angle obtained should be within quadrant II and III, namely within (π/2 to π) or (π to 3π/2). X-Y function can be used to measure the phase deviation occurred when the signal under test passes through a circuit network.
  • Page 77: Sequence Mode

    SDS1000X-E User Manual Sequence Mode Sequence is also a kind of acquisition mode, which does not display waveform during sampling process. It improves the waveform capture rate, and the maximal capture rate is 400,000 wfs/s. So it can capture the small probability event effectively. The oscilloscope runs and fills a memory segment for each trigger event.
  • Page 78 SDS1000X-E User Manual every frame and shows the frame number that displaying on the screen. Press the Frame No. softkey; and then turn the Universal Knob to select the frame to display. Press the softkey to replay the waveform from the current frame to 1. Press the softkey to stop replay.
  • Page 79: Trigger

    SDS1000X-E User Manual Trigger For trigger, you set certain trigger condition according to the requirement and when a waveform in the waveform stream meets this condition, the oscilloscope captures this waveform as well as the neighboring part and displays them on the screen. For digital oscilloscope, it displays waveform continuously no matter whether it is stably triggered, but only stable trigger can ensures stable display.
  • Page 80 SDS1000X-E User Manual  Trigger Level  Trigger Coupling  Trigger Holdoff  Noise Rejection  Trigger Type WWW.SIGLENT.COM...
  • Page 81: Trigger Source

    SDS1000X-E User Manual Trigger Source The 2-channel oscilloscope’s trigger source includes analog channels, EXT, EXT/5 and AC Line. The 4-channel oscilloscope’s trigger source includes analog channels and AC Line. Press the Setup button on the front panel to enter the TRIGGER function menu; press the Source softkey and then turn the Universal Knob to select the desired trigger source.
  • Page 82: Trigger Mode

    SDS1000X-E User Manual Trigger Mode The oscilloscope’s trigger mode includes auto, normal and single. Trigger mode affects the way in which the oscilloscope searches for the trigger After the oscilloscope starts running, the oscilloscope operates by first filling the pre-trigger buffer. It starts searching for a trigger after the pre-trigger buffer is filled and continues to flow data through this buffer while it searches for the trigger.
  • Page 83 SDS1000X-E User Manual Note: You can force the oscilloscope to trigger by pressing the Single button twice. The trigger status in the upper left corner of the screen will be displayed as "FStop". WWW.SIGLENT.COM...
  • Page 84: Trigger Level

    SDS1000X-E User Manual Trigger Level Trigger level and slope define the trigger point, You can adjust the trigger level for a selected analog channel by turning the Trigger Level Knob. You can push the Trigger Level Knob to set the level to the waveform's 50% value immediately.
  • Page 85: Trigger Coupling

    SDS1000X-E User Manual Trigger Coupling Press the Setup button on the front panel to enter the TRIGGER function menu, and then press the Coupling softkey and turn the Universal Knob or press the Coupling softkey continually to select the desired coupling mode. The oscilloscope provides 4 kinds of trigger coupling modes: DC: allow DC and AC components into the trigger path.
  • Page 86: Trigger Holdoff

    SDS1000X-E User Manual Trigger Holdoff Trigger holdoff can be used to stably trigger the complex waveforms (such as pulse series). Holdoff time is the amount of time that the oscilloscope waits before re-arming the trigger circuitry. The oscilloscope will not trigger until the holdoff time expires. Use the holdoff to trigger on repetitive waveforms that have multiple edges (or other events) between waveform repetitions.
  • Page 87: Noise Rejection

    SDS1000X-E User Manual Noise Rejection Noise Reject adds additional hysteresis to the trigger circuitry. By increasing the trigger hysteresis band, you reduce the possibility of triggering on noise. However, this also decreases the trigger sensitivity so that a slightly larger signal is required to trigger the oscilloscope.
  • Page 88 SDS1000X-E User Manual Figure 27 Turn on the Noise Reject If the signal you are probing is noisy, you can set up the oscilloscope to reduce the noise in the trigger path and on the displayed waveform. First, stabilize the displayed waveform by removing the noise from the trigger path.
  • Page 89: Trigger Type

    SDS1000X-E User Manual Trigger Type The oscilloscope provides abundant advanced trigger functions, including various serial bus triggers.  Edge trigger  Slope trigger  Pulse trigger  Video trigger  Window trigger  Interval trigger  DropOut trigger  Runt trigger ...
  • Page 90: Edge Trigger

    SDS1000X-E User Manual Edge Trigger Edge trigger distinguishes the trigger points by seeking the specified edge (rising, falling, alter) and trigger level. Press the Setup button on the front panel to enter the TRIGGER system function menu. Press the Type softkey; turn the Universal Knob to set select Edge and then push the knob to confirm.
  • Page 91 SDS1000X-E User Manual Note: Press the Auto Setup button will set the trigger type to Edge and slope to rising. WWW.SIGLENT.COM...
  • Page 92: Slope Trigger

    SDS1000X-E User Manual Slope Trigger The slope trigger looks for a rising or falling transition from one level to another level in greater than or less than a certain amount of time. In the oscilloscope, positive slope time is defined as the time difference between the two crossing points of trigger level line A and B with the positive edge as shown in the figure below.
  • Page 93 SDS1000X-E User Manual Figure 29 Slope Trigger Press the Limit Range softkey; then turn the Universal Knob to select the desired slope condition, and push down the knob to confirm. <= (less than a time value): trigger when the positive or negative slope time of ...
  • Page 94: Pulse Trigger

    SDS1000X-E User Manual Pulse Trigger Trigger on the positive or negative pulse with a specified width. Press the Setup button on the front panel to enter the TRIGGER function menu. Press the Type softkey; turn the Universal Knob to select Pulse and then push the knob to confirm.
  • Page 95 SDS1000X-E User Manual For example, for a positive pulse, if you set t (pulse real width) ≥100ns and t ≤ 300ns, the waveform will trigger. --][-- (outside a range of time value): trigger when the positive or negative pulse  time of the input signal is greater than the specified upper limit of time and lower than the specified lower limit of time value.
  • Page 96: Video Trigger

    SDS1000X-E User Manual Video Trigger Video triggering can be used to capture the complicated waveforms of most standard analog video signals. The trigger circuitry detects the vertical and horizontal interval of the waveform and produces triggers based on the video trigger settings you have selected. The oscilloscope supports standard video signal field or line of NTSC (National Television Standards Committee), PAL (Phase Alternating Line) HDTV (High Definition Television) and custom video signal trigger.
  • Page 97 SDS1000X-E User Manual (line value)/8 The table below takes Of Lines as 800 as an example to explain the relation between Of Lines, Of Fields, Interlace, Trigger Line and Trigger Field. Of Lines Of Fields Interlace Trigger Line Trigger Field 1,2,4 or 8 1, 1~2, 1~4, 1~8 1,2,4 or 8...
  • Page 98 SDS1000X-E User Manual Figure 31 Video Trigger To Use Custom Video Trigger Custom video trigger supports frame rate of 25Hz, 30Hz, 50Hz and 60Hz, and the line range is available from 300 to 2000. The steps below show how to set custom trigger. Press the Setup button on the front panel to enter the TRIGGER function menu.
  • Page 99: Window Trigger

    SDS1000X-E User Manual Window Trigger Windows trigger provides a high trigger level and a low trigger level. The instrument triggers when the input signal passes through the high trigger level or the low trigger level. There are two kinds of window types: Absolute and Relative. They have different trigger level adjustment methods.
  • Page 100 SDS1000X-E User Manual level. Figure 32 Absolute Window Trigger To set window trigger via Relative window type: Press the Setup button on the front panel to enter the TRIGGER system function menu. Press the Type softkey; then use the Universal Knob to select Window and push down the knob to confirm.
  • Page 101 SDS1000X-E User Manual Figure 33 Relative Window Trigger Coupling and noise reject can be set in Window trigger, see the sections "Trigger Coupling" and "Noise Rejection" for details. WWW.SIGLENT.COM...
  • Page 102: Interval Trigger

    SDS1000X-E User Manual Interval Trigger Trigger when the times difference between the neighboring rising or falling edges meets the time limit (<=, >=, [--,--], --][--). To set interval trigger: Press the Setup button on the front panel to enter the TRIGGER system function menu.
  • Page 103 SDS1000X-E User Manual Figure 34 Interval Trigger Coupling and noise reject can be set in interval trigger, see the sections "Trigger Coupling" and "Noise Rejection" for details. WWW.SIGLENT.COM...
  • Page 104: Dropout Trigger

    SDS1000X-E User Manual Dropout Trigger Dropout trigger includes two types: edge and state. Edge Trigger when the time interval (△T) from when the rising edge (or falling edge) of the input signal passes through the trigger level to when the neighboring rising edge (or falling edge) passes through the trigger level is greater than the timeout time set, as shown in the figure below.
  • Page 105 SDS1000X-E User Manual Figure 35 Edge Dropout Trigger To set state Dropout trigger: Press the Setup button to enter the TRIGGER system function menu. Press the Type softkey; then turn the Universal Knob to select Dropout and push down the knob to confirm. Press the Source softkey;...
  • Page 106 SDS1000X-E User Manual Coupling and noise reject can be set in dropout trigger, see the sections "Trigger Coupling" and "Noise Rejection" for details. WWW.SIGLENT.COM...
  • Page 107: Runt Trigger

    SDS1000X-E User Manual Runt Trigger The Runt trigger looks for pulses that cross one threshold but not another as shown in the picture below. A positive runt pulse across through a lower threshold but not an upper threshold.  A negative runt pulse across through an upper threshold but not a lower threshold. ...
  • Page 108 SDS1000X-E User Manual Figure 37 Runt Trigger Coupling and noise reject can be set in runt trigger, see the sections "Trigger Coupling" and "Noise Rejection" for details. WWW.SIGLENT.COM...
  • Page 109: Pattern Trigger

    SDS1000X-E User Manual Pattern Trigger The Pattern trigger identifies a trigger condition by looking for a specified pattern. The pattern trigger can be expanded to incorporate delays similar to other triggers. Pattern durations are evaluated using a timer. The timer starts on the last edge that makes the pattern “true”.
  • Page 110 SDS1000X-E User Manual Press the Time softkey; then turn the Universal Knob to select the desired time value. Press the Holdoff Close softkey to turn on the Holdoff function; then turn the Universal Knob to select the desired value. Figure 38 Pattern Trigger Holdoff can be set in pattern trigger, see the sections "Trigger Holdoff"...
  • Page 111: Serial Trigger And Decode

    SDS1000X-E User Manual Serial Trigger and Decode The oscilloscope provides I2C, SPI, UART, CAN and LIN serial trigger and decode. This chapter introduces the method of triggering and decoding these serial signals in details. The contents of this chapter:  I2C Trigger and Decode ...
  • Page 112: I2C Trigger And Serial Decode

    SDS1000X-E User Manual I2C Trigger and Serial Decode Please in order of “Setup for I2C Signals”, “I2C Trigger” and “I2C Serial Decode” to trigger and decode the signals. Setup for I2C Signals Setting the I2C (Inter-IC bus) signal includes two steps: connecting the serial data signal (SDA) and serial clock signal (SCK) to oscilloscope, specifying the threshold voltage of each input signal.
  • Page 113: I2C Trigger

    SDS1000X-E User Manual I2C Trigger This part introduces the nine kinds of trigger conditions (Start, Stop, Restart, No Ack, EEPROM, 7 Addr&Data, 10 Addr&Data and Data Length) and the methods of setting them. Trigger Conditions Start Condition— the oscilloscope will be triggered when SDA signal transitions from ...
  • Page 114 SDS1000X-E User Manual If you have set either Data1’s or Data2’s value, and the signal has a data is the  same as that value. If you have set both Data1’s and Data2’s value, the signal should has two consecutive data, the first data’s value is Data1, second data value is Data2.
  • Page 115 SDS1000X-E User Manual Data Length — When SDA data’s length is equal to the value of Byte Length and  address’s length is the same as set value, the oscilloscope will be triggered. Byte length is in the range of 1 to 12 bits. Operation Steps Press the Setup to enter the TRIGGER function menu.
  • Page 116: I2C Serial Decode

    SDS1000X-E User Manual I2C Serial Decode After completing the setup of I2C signal and trigger, we will decode I2C signals. Operation steps as follows. Press Decode→ Decode. Select one of the options from the Decode1 and Decode2. Press the Display and select On to display the result of decoding. Press the List to enter the LIST function menu.
  • Page 117: Spi Trigger And Serial Decode

    SDS1000X-E User Manual SPI Trigger and Serial Decode Please in order of “Setup for SPI Signals”, “SPI Trigger” and “SPI Serial Decode” to trigger and decode the signals. Setup for SPI Signals Setting the SPI (Serial Peripheral Interface) signal includes two steps: connecting the CLK, MISO, MOSI and CS signals to oscilloscope;...
  • Page 118 SDS1000X-E User Manual Press the softkey to return previous menu. Figure 46 MISO Menu Set MOSI: Press the MOSI softkey to enter the MOSI menu. Press the MOSI softkey to select the channel that is connected to the SPI MOSI signal.
  • Page 119: Spi Trigger

    SDS1000X-E User Manual SPI Trigger This part will provide a brief introduction and description for the operation of the SPI trigger. Press the Setup button to enter the TRIGGER function menu. Press the Type and select Serial. Press the Protocol and select SPI. Press the Trigger Setting softkey.
  • Page 120: Spi Serial Decode

    SDS1000X-E User Manual SPI Serial Decode After completing the setup of SPI signal and trigger, we will decode SPI signals. Operation steps as follows. Press Decode→Decode. Select one of the options from the Decode1 and Decode2. Press the Display and select On to display the result of decoding. Press the List to enter the LIST function menu.
  • Page 121: Uart Trigger And Serial Decode

    SDS1000X-E User Manual UART Trigger and Serial Decode Please in order of “Setup for UART Signals”, “UART Trigger” and “UART Serial Decode” to trigger and decode the signals. Setup for UART Signals Press the Decode key to enter the DECODE function menu. Press the Decode softkey and select the desired slot (Decode1 or Decode2).
  • Page 122 SDS1000X-E User Manual 12. Press the Stop Bit softkey to set the length of stop bit (1, 1.5 or 2 bits). 13. Press the Next Page softkey. 14. Press the Bit Order softkey to select the bit order (LSB or MSB). 15.
  • Page 123: Uart Trigger

    SDS1000X-E User Manual UART Trigger This part shows a brief introduction and description for the operation of the UART trigger. Press the Setup button to enter the TRIGGER function menu. Press the Type and select Serial. Press the Protocol and select UART. Press the Trigger Setting softkey to enter UART TRIG SET menu.
  • Page 124: Uart Serial Decode

    SDS1000X-E User Manual UART Serial Decode After completing the setup of UART signal and trigger, we will decode UART signals. Operation steps as follows. Press Decode→Decode. Select one of the options from the Decode1 and Decode2. Press the Display and select On to display the result of decoding. Press the List to enter the LIST function menu.
  • Page 125 SDS1000X-E User Manual Figure 56 UART Decode Bus Display The lists of decoding result: Time— the horizontal displacement between current frame and trigger position.  RX — the receiving channel.  TX — the transmitting channel.  RX Err— Parity error or unknown error in the data received. ...
  • Page 126: Can Trigger And Serial Decode

    SDS1000X-E User Manual CAN Trigger and Serial Decode Please in order of “Setup for CAN Signals”, “CAN Trigger” and “CAN Serial Decode” to trigger and decode the signals. Setup for CAN Signals Press the Decode key to enter the DECODE function menu. Press the Decode softkey and select the desired slot (Decode1 or Decode2).
  • Page 127: Can Trigger

    SDS1000X-E User Manual CAN Trigger This part will provide a brief introduction and description for the operation of the CAN trigger. Trigger Conditions Start— the oscilloscope will be triggered at the start bit of a frame.  Remote — the oscilloscope will be triggered by a remote frame with specified ID. ...
  • Page 128 SDS1000X-E User Manual Figure 59 CAN Trigger WWW.SIGLENT.COM...
  • Page 129: Can Serial Decode

    SDS1000X-E User Manual CAN Serial Decode After completing the setup of can signal and trigger, we will decode CAN signals. Operation steps as follows. Press Decode→ Decode. Select one of the options from the Decode1 and Decode2. Press the Display and select On to display the result of decoding. Press the List to enter the LIST function menu.
  • Page 130 SDS1000X-E User Manual Figure 61 CAN Decode List Display WWW.SIGLENT.COM...
  • Page 131: Lin Trigger And Serial Decode

    SDS1000X-E User Manual LIN Trigger and Serial Decode Please take the order of “Setup for LIN Signals”, “LIN Trigger” and “LIN Serial Decode” to trigger and decode the signals. Setup for LIN Signals There are two steps of setting the LIN signal, connecting the signal to oscilloscope, specifying the parameters of each input signal.
  • Page 132: Lin Trigger

    SDS1000X-E User Manual LIN Trigger This part will provide a brief introduction and description for the operation of the LIN trigger. Trigger Conditions Break — the oscilloscope will be triggered at the position of break field’s break  delimiter. ID (Frame ID) — the oscilloscope will be triggered at the position of identifier field’s ...
  • Page 133 SDS1000X-E User Manual Figure 63 LIN Trigger WWW.SIGLENT.COM...
  • Page 134: Lin Serial Decode

    SDS1000X-E User Manual LIN Serial Decode After completing the setup of LIN signal and trigger, we will decode LIN signals. Operation steps as follows. Press Decode→ Decode. Select one of the options from the Decode1 and Decode2. Press the Display and select On to display the result of decoding. Press the List to enter the LIST function menu.
  • Page 135 SDS1000X-E User Manual Figure 65 LIN Decode Bus Display The list of decoding result: Time— the horizontal displacement between current frame and trigger position.  ID — the value of frame’s Protected Identifier Field.  Data Length — the length of Data Field. ...
  • Page 136: Reference Waveform

    SDS1000X-E User Manual Reference Waveform The oscilloscope can save analog channel or math waveforms to the reference waveform locations in the oscilloscope. Then, a reference waveform can be displayed and compared against other waveforms. All reference waveforms can be displayed at a time. The contents of this chapter: ...
  • Page 137: Save Ref Waveform To Internal Memory

    SDS1000X-E User Manual Save REF Waveform to Internal Memory Do the following steps to save the REF waveform to internal memory: Press the REF button on the front to enter the REF WAVE function menu. Note that when the time horizontal format is in X-Y mode, REF function cannot be enabled. Press the Source softkey;...
  • Page 138: Adjust Ref Waveform

    SDS1000X-E User Manual Adjust REF Waveform Please refer to the “To Display REF Waveform” above to display the desired reference waveform. Press the Scale and Position softkey and turn the Universal Knob to adjust the vertical scale and position of the reference waveform. The vertical scale and position information display at the middle of the screen.
  • Page 139 SDS1000X-E User Manual the same location to cover it. Or follow the Save/Recall → Recall → type and select Security Erase to clear the stored waveform. WWW.SIGLENT.COM...
  • Page 140: Math

    SDS1000X-E User Manual Math The oscilloscope supports many math operations between analog channels including addition (+), subtraction (-), multiplication (*), division (/), FFT, differential (d/dt), integral (∫dt), square root (√). The resulting math waveform is displayed in white and labeled with “M”.
  • Page 141: Units For Math Waveforms

    SDS1000X-E User Manual Units for Math Waveforms Use the channel function menu to set the unit of each channel to “V” or “A”. The oscilloscope math operation includes units as below: Math Operation Unit Addition (+)or subtraction (-) V, A multiplication (*) 2, A 2 or W...
  • Page 142: Math Operators

    SDS1000X-E User Manual Math Operators The oscilloscope supports math count operation (Addition, subtraction, multiplication, division), FFT (Fourier transform) operation and math function operation (differential, integral, square root). Addition or Subtraction Math operators perform arithmetic operations add or subtract operation on any two analog input channels.
  • Page 143: Multiplication And Division

    SDS1000X-E User Manual Multiplication and Division Math operators perform arithmetic operations multiplication or division operation on any two analog input channels. When you select multiplication or division, the Source A and Source B values are multiplied or divided point by point and the result is displayed. Press the Math button on the front panel to enter the MATH function menu.
  • Page 144: Fft Operation

    SDS1000X-E User Manual FFT Operation FFT is used to compute the fast Fourier transform using analog input channels. FFT takes the digitized time record of the specified source and transforms it to the frequency domain. When the FFT function is selected, the FFT spectrum is plotted on the oscilloscope display as magnitude in dBV versus frequency.
  • Page 145 SDS1000X-E User Manual carefully to make an appropriate option according to the input signal. Window Applications and Characteristics These are normally used when the signal is transient (completely contained in the time-domain window) or known to have a Rectangle fundamental frequency component that is an integer multiple of the fundamental frequency of the window.
  • Page 146 SDS1000X-E User Manual Figure 73 HORIZONTAL Menu Press the Center softkey, and then turn the Universal Knob to select the desired  center frequency. Press the Hz/div softkey, and then turn the Universal Knob to select the desired  resolution frequency. Press the Tools softkey to enter TOOLS menu.
  • Page 147 SDS1000X-E User Manual Figure 77 Marker Control Menu Press the Marker softkey continuously to select the marker number from NO.1~NO.8. Press the Show Marker softkey continuously to turn on or off the selected mark. Press the Frequency softkey to set the frequency value of the selected marker.
  • Page 148: Math Function Operation

    SDS1000X-E User Manual Note: Signals with DC components or deviation would cause error or deviation of the FFT  waveform components. To reduce the DC components, set the Channel Coupling to AC. To reduce the random noise and aliasing frequency components of repetitive or ...
  • Page 149 SDS1000X-E User Manual difference, and it ranges from 0.02div to 0.40div. “div” indicates the number of the pixel points that each division has. The oscilloscope has 50 pixel points per division. Take 0.2div as an example: 0.2*50=10. It means to calculate the ten point’s discrete time derivative of the selected source, and the Δ...
  • Page 150 SDS1000X-E User Manual Integrate dt (integrate) calculates the integral of the selected source. You can use integrate to calculate the energy of a pulse in volt- seconds or measure the area under a waveform. dt plots the integral of the source using the "Trapezoidal Rule". The equation is: ∑...
  • Page 151 SDS1000X-E User Manual Figure 81 Integral with Offset WWW.SIGLENT.COM...
  • Page 152 SDS1000X-E User Manual Square Root Square root ( ) calculates the square root of the selected source. Where the transform is undefined for a particular input, holes (zero values) appear in the function output. Figure 82 Square Root WWW.SIGLENT.COM...
  • Page 153: Cursors

    SDS1000X-E User Manual Cursors Cursors are horizontal and vertical markers that indicate X- axis values and Y- axis values on a selected waveform source. You can use cursors to make custom voltage, time measurements on oscilloscope signals. X Cursors X cursors are vertical dashed lines that adjust horizontally and can be used to measure time (when the source is FFT waveform, X cursors measure frequency).
  • Page 154 SDS1000X-E User Manual Use the Universal Knob to set the Y1 and Y2 cursor values and the values are displayed in the cursors box in the top left corner of the screen along with the difference between Y1 and Y2 (△Y). When set cursor type to Y2-Y1, use Universal Knob will move the Y1 and Y2 cursors together.
  • Page 155: Make Cursor Measurements

    SDS1000X-E User Manual Make Cursor Measurements Press the Cursors button on the front panel to enter the CURSOR function menu. Press the Mode softkey and set the cursors mode to Manual or Track. Press the Source softkey, and then use the Universal Knob to select the desired source.
  • Page 156 SDS1000X-E User Manual Figure 83 Measure Pulse Width WWW.SIGLENT.COM...
  • Page 157: Measure

    SDS1000X-E User Manual Measure The oscilloscope provides measurements of 36 waveform parameters and the statistics. It contains voltage, time and delay parameters. Voltage and time parameters are under Type option. The results of the last four selected measurements are displayed at the bottom of screen and above the menu. Delay parameters are under the All Measure submenu.
  • Page 158: Type Of Measurement

    SDS1000X-E User Manual Type of Measurement Voltage Measurements Voltage measurements include 15 kinds of voltage parameter measurements. Figure 84 Voltage Measurements Peak-Peak: Difference between maximum and minimum data values. Maximum: Highest value in input waveform. Minimum: Lowest value in input waveform. Amplitude: Difference between top and base in a bimodal signal, or between max and min in an unimodal signal.
  • Page 159: Time Measurements

    SDS1000X-E User Manual Figure 85 Overshoot 14. Preshoot: Preshoot is distortion that precedes a major edge transition expressed as a percentage of Amplitude. The X cursors show which edge is being measured (edge closest to the trigger reference point). Figure 86 Preshoot 15.
  • Page 160: Delay Measurements

    SDS1000X-E User Manual Figure 87 Time Measurements Period: Period for every cycle in waveform at the 50% level, and positive slope. Frequency: Frequency for every cycle in waveform at the 50% level ,and positive slope + Width: Width measured at 50% level and positive slope. Width: Width measured at 50% level and negative slope.
  • Page 161 SDS1000X-E User Manual FRLF: Time from the first rising edge of channel A to the last falling edge of channel FFLR: Time from the first falling edge of channel A to the last rising edge of channel FFLF: Time from the first falling edge of channel A to the last falling edge of channel 10.
  • Page 162: Automatic Measurement

    SDS1000X-E User Manual Automatic Measurement Perform the steps below and select voltage or time parameters to make automatic measurement. Press the Measure button on the front panel to enter the MEASURE function menu. At the same, the frequency and period are enabled with the current trigger channel, the statistics also was enabled.
  • Page 163 SDS1000X-E User Manual Figure 89 Added the Measurement Note: if the parameter does not match the measure condition, it will display as “****”. WWW.SIGLENT.COM...
  • Page 164: All Measurement

    SDS1000X-E User Manual All Measurement All measurement could measure all the voltage, time and delay parameters of the current measurement source and display the results on the screen. Figure 90 All Parameters Measurement Do the following steps to make all parameters measurement. Press the Measure button on the front panel to enter the MEASURE function menu.
  • Page 165: Gate Measurement

    SDS1000X-E User Manual Gate Measurement The SDS1000X-E supports gate measurement and performs the selected measurement within the upper and lower limits of the gate. Setting the gate will affect the measurement of all voltage, time, and delay parameters. Press Measure → Gate → On to open the gate measurement. Press the Gate A to move the position of gate A by the Universal Knob.
  • Page 166: Display

    SDS1000X-E User Manual Display You can set the display type, color, persistence, grid type, waveform intensity, grid brightness and transparence. The contents of this chapter:  Display Type  Color Display  Persistence  Clear the Display  Grid Type ...
  • Page 167: Display Type

    SDS1000X-E User Manual Display Type Press the Display button on the front panel, and then press the Type softkey to select Vectors or Dots display type. Vectors: the sample points are connected by lines and displayed. Normally, this mode  can provide the most vivid waveform to view the steep edge of the waveform (such as square waveform).
  • Page 168: Color Display

    SDS1000X-E User Manual Figure 93 Dots Display Color Display Color temperature adopts the change of waveforms’ color to reflect the change of the waveforms’ appearing probability. The greater the probability that the waveform appears, the warmer the color is; the smaller the waveform appears, the colder the color is. The picture below shows the change of color from cold to warm.
  • Page 169: Persistence

    SDS1000X-E User Manual Persistence With persistence, the oscilloscope updates the display with new acquisitions, but does not immediately erase the results of previous acquisitions. All previous acquisitions are displayed with reduced intensity. New acquisitions are shown in their normal color with normal intensity.
  • Page 170: Clear Display

    SDS1000X-E User Manual Clear Display Press the Display button on the front panel to enter the DISPLAY function menu; press the Clear Display softkey to clear all the waveforms displaying on the screen and acquire and display new waveforms. Grid Type To select grid type Press the Display/Persist button on the front panel to enter the DISPLAY function menu.
  • Page 171: Grid Brightness

    SDS1000X-E User Manual Note: Waveform intensity adjustment affects analog channel waveforms only (not math waveforms, reference waveforms, digital waveforms, etc.). Grid Brightness Do the following steps to adjust the grid brightness: Press the Display button on the front panel to enter the DISPLAY function menu. Press the Next Page softkey to go to the second page of the Display function menu.
  • Page 172: Save And Recall

    SDS1000X-E User Manual Save and Recall Oscilloscope setups, waveforms, pictures, and CSV files can be saved to internal oscilloscope memory or to a USB storage device. The saved setups, waveforms can be recalled later. The oscilloscope provides an USB Host interface on the front panel to connect an USB device for external storage.
  • Page 173: Save Type

    SDS1000X-E User Manual Save Type The oscilloscope supports setups, waveforms, pictures and CSV files storage. The default save type is setups. 1. Setups It’s the default storage type of the oscilloscope. It saves the settings of the oscilloscope in internal or external memory in “*.SET” format. At most 20 setting files (from No.1~No.20) can be stored in internal memory.
  • Page 174 SDS1000X-E User Manual 8. Matlab The oscilloscope saves the waveform data in external memory in “*.DAT” format. The data of all the channels turned on can be saved in the same file. The recall of Matlab file is not supported. 9.
  • Page 175: Internal Save And Recall

    SDS1000X-E User Manual Internal Save and Recall Internal save and recall support Setups in Save/Recall. In the following part, the save and recall method and procedures are introduced. Save the specified oscilloscope setting in internal memory.  Connect the signal to the oscilloscope and obtain stable display. Press Save/Recall button on the front panel to enter the SAVE/RECALL function menu.
  • Page 176: External Save And Recall

    SDS1000X-E User Manual External save and recall Before using external storage and recall, make sure that the USB flash device is connected correctly. External storage supports all the types of files in save, but in recall, Picture and CSV are not supported. Save the specified type of file in the external USB flash device.
  • Page 177 SDS1000X-E User Manual Figure 97 Select Save Location After the save position is selected, press the New softkey to turn on the interface as shown in the figure below. Refer to the descriptions in “To Create a new file or fold”...
  • Page 178 SDS1000X-E User Manual Load the specified type of file in the external USB storage device.  Press the Save/Recall button on the front panel to enter the SAVE/RECALL function menu. Press the Recall softkey to enter the RECALL menu. Press the Type softkey to select Setup or Waveform. Press the Recall from softkey to select External.
  • Page 179: Disk Management

    SDS1000X-E User Manual Disk Management Disk management aim at the save and recall operations after the oscilloscope is connected with a USB storage device. Before using external disk, make sure that the USB storage device is connected correctly. Execute the following operations through the disk management menu: ...
  • Page 180: Create A New File Or Folder

    SDS1000X-E User Manual Create a New File or Folder This operation is only valid in external storage. The oscilloscope supports English input method. The file name or folder name can contain letters, numbers, underscores and spaces. Let’s use an example to introduce how to create a file or folder. Example: create a file or folder named “SDS105X”...
  • Page 181: Delete A File Or Folder

    SDS1000X-E User Manual Delete a File or Folder This operation is only valid in external storage. Press the Save/Recall button on the front to enter the SAVE/RECALL function menu. Press the Save softkey, and then turn the Universal Knob to select one of the type (if select Setups, please set the Save To option to External).
  • Page 182: Digital Channels(Option)

    This chapter describes how to use the digital channels of a Mixed-Single Oscilloscope (MSO). The digital channels are enabled on SDS1000X-E series oscilloscopes (only 4 channels scope) that have installed the MSO activation license. As an external module, SLA1016 is independent of the host, and has its own system, so it needs to be upgraded if necessary.
  • Page 183: Connect The Digital Probes

    SDS1000X-E User Manual Connect the Digital Probes 1. If necessary, turn off the power supply to the device-under-test. Turning off the power to the device-under-test prevents damage that might occur  if you accidentally short lines together while connecting probes. You can leave the oscilloscope powered on because no voltage appears at the probes.
  • Page 184: Acquire Digital Waveform

    SDS1000X-E User Manual Acquire Digital Waveform Press the Digital button on the front panel to open the digital channels and start acquiring digital channel waveforms. For digital channels, each time the oscilloscope takes a sample it compares the input voltage to the logic threshold. If the voltage is above the threshold, the oscilloscope stores a 1 in the sample memory;...
  • Page 185: Digital Channels Position

    SDS1000X-E User Manual Figure 102 High Display Type The display type control lets you spread out or compress the digital traces vertically on the display for more convenient viewing. Digital Channels Position Press the Digital button on the front panel to open the DIGITAL function menu and display the digital channel waveforms.
  • Page 186: All Digital Channels

    SDS1000X-E User Manual All Digital Channels Press the Digital button on the front panel to open the DIGITAL function menu. Press the Channel Group softkey to select On or Off to switch all digital channels which in this group on or off. Also, under the DIGITAL function menu, press the Digital button on the front panel to switch all digital channels off.
  • Page 187: Digital Bus

    SDS1000X-E User Manual Digital Bus Digital channels may be grouped and displayed as a bus, with each value displayed at the bottom of the display in hex or binary. You can create up two buses. To configure and display each bus, do the following steps: Press the Digital button on the front panel to open the DIGITAL function menu and display the digital channel waveforms.
  • Page 188: Deskew

    SDS1000X-E User Manual Figure 105 Digital Bus Deskew Press the Digital button on the front panel to open the DIGITAL function menu and display the digital channel waveforms. Press the Deskew softkey, and then turn the Universal Knob to select to change deskew.
  • Page 189: System Setting

    SDS1000X-E User Manual System Setting System Status Press Digital→ NextPage2/2 → System ,then select the System Status option to view the digital system information , including software version, hardware version, and serial number. After finished, press the return soft key to quit the interface of system information. Figure 106 Digital System Information Interface Update The software version file of the Digital can be updated directly via U-disk.
  • Page 190: Remove Device

    SDS1000X-E User Manual Figure 107 Digital Update Interface After the updating is finished, the Digital device will automatically disconnected and display a message “Update completed, please reconnect Digital device!” Note:Don't cut off the power during the Digital device is being updated! Remove Device Press Digital→...
  • Page 191: System Setting

    SDS1000X-E User Manual System Setting This function module supports the oscilloscope’s system-related function, such as system status, language, sound and some other advanced setting, such as do self cal, update and remote interface configure. The contents of this chapter:  View System Status ...
  • Page 192: View System Status

    SDS1000X-E User Manual View System Status Do the following steps to view the system status: Press the Utility button on the front to enter the UTILITY function menu. Press the System Status softkey to view the system status of the oscilloscope. The system status includes the information below: Startup Times: record the boot-strap times of the oscilloscope.
  • Page 193 SDS1000X-E User Manual 5 ℃. Make sure that the oscilloscope has been warmed up or operated for more than 30 minutes before the self-calibration. Do the following steps to do self-calibration: Disconnect all the input channels. Press the Utility button on the front panel, and then press the Do Self Cal softkey, and the oscilloscope will pop-out the message box shown as below: Figure 109 Do Self Cal Press the Single button on the front panel to perform the self-calibration program.
  • Page 194: Quick-Cal

    SDS1000X-E User Manual Quick-Cal Quick calibration can correct the measurement deviation caused by temperature, so that you can get more accurate measurements If the ambient temperature of your current operating oscilloscope is unstable, press Utility → Quick-Cal softkey to select On to enable quick calibration. Sound When the sound is enabled, you can hear the sound of the beeper when you press a function key or a menu softkey or when the prompt message pops up.
  • Page 195: Pass/Fail Test

    SDS1000X-E User Manual Pass/Fail Test One way to verify a waveform's compliance to a particular set of parameters is to use pass/fail testing. A pass/fail defines a region of the oscilloscope's display in which the waveform must remain in order to comply with chosen parameters. Compliance to the mask is verified point- by- point across the display.
  • Page 196: Save And Recall Test Mask

    SDS1000X-E User Manual Press the X Mask or Y Mask softkey; and then turn the Universal Knob to select the desired value. The range is from 0.02div to 4div. Press the Create Mask button to create the mask. Whenever the Create Mask softkey is pressed the old mask is erased and a new mask is created.
  • Page 197 SDS1000X-E User Manual Press the Next Page softkey to go to the second page of the UTILITY function menu. Press the Pass/Fail softkey to enter the PASS/FAIL function menu. Press the Enable Test softkey to select On to enable the pass/ fail test. Press the Source softkey to select the desired channel.
  • Page 198 SDS1000X-E User Manual Press the Save softkey to enter the file SAVE/RECALL system. 10. Save the test mask file refer to the “Save to file XXX.msk” chapter. Recall Test Mask from External Memory Do the following steps to save the test mask f external memory: Press the Utility button on the front panel to enter the UTILITY function menu.
  • Page 199: Arbitrary Waveform Generator(Option)

    SDS1000X-E User Manual Arbitrary Waveform Generator(Option) SDS1000X-E (only 4 channels scope) supports an external Arbitrary Waveform Generator (AWG), which can easily and quickly provide multiple input signals to users. The AWG provides two kinds of waveforms: the standard waveform and the Arb. The Arb single consists of two types: the system’s built-in waveforms and the stored waveforms.
  • Page 200: Output

    SDS1000X-E User Manual Output Connect AWG with USB cable, and the oscilloscope interface indicates "AWG device connection success", Press the Utility →Next Page4/4→ AWG,to enter the function menu interface of the AWG system as shown below, including: Output, Wave, Setting , System, Remove Device.
  • Page 201 SDS1000X-E User Manual Knob and the corresponding function software under the menu. Wave Frequency Amplitude Offset Parameters Type Range (High-Z) (High-Z) Frequency/Period/Amplitude/High-L Sine 1uHz~25MHz 4mV~6V ± 3.0V evel/Offset/Low-Level value. Frequency/Period/Amplitude/High-L Square 1uHz~10MHz 4mV~6V ± 3.0V evel/Offset/Low-Level/Duty value. Frequency/Period/Amplitude/High-L 1uHz~300KH Ramp evel/Offset/Low-Level/Symmetry 4mV~6V ±...
  • Page 202: Setting

    SDS1000X-E User Manual Figure 113 Built-in Arb Interface Setting Figure 114 AWG Setting Interface Output Load Press Utility→ NextPage4/4→ AWG → Setting→ Output Load to set High-Z or 50Ω. Sync Output Press Utility→ NextPage4/4→ AWG→ Setting→ Sync Output, the AWG provides Sync output through the [Aux In/Out] connector on the rear panel.
  • Page 203: Systems

    SDS1000X-E User Manual state is set to ON, overvoltage protection of AWG output port take effect once the condition is meeting (the absolute value of input voltage is higher than 4V±0.5V). When overvoltage protection occurs, a message will be displayed and the output is disabled. Default Press Utility →NextPage4/4→...
  • Page 204 SDS1000X-E User Manual Figure 115 AWG System Information Interface Update The software version file of the AWG can be updated directly via U-disk. Follow the steps below: Insert U-disk with firmware update file (*.ads) to USB host interface on the front panel of the oscilloscope.
  • Page 205: Remove Device

    SDS1000X-E User Manual Figure 116 AWG Update Interface After the updating is finished, the AWG will automatically disconnected and display a message “Update completed, please reconnect AWG device!” Note:Don't cut off the power during the AWG is being updated! Remove Device Press Utility→NextPage4/4→AWG→Remove Device, and the oscilloscope interface display "AWG device removed!", the device can be pulled.
  • Page 206: Io Set

    SDS1000X-E User Manual IO Set The oscilloscope provides abundant IO interfaces, including: USB Device, LAN and Aux Output. USB Device Do the following steps to set the oscilloscope to communicate with PC via USB: Install the USBTMC device driver on PC. Suggest you install NI Vista. Connect the oscilloscope with PC using a standard USB cable Press the Utility button on the front panel to enter the UTILITY function menu.
  • Page 207: Wlan

    SDS1000X-E User Manual Figure 117 LAN Setting Interface WLAN Only 4 channels scope supports this function. Do the following steps to set the oscilloscope to communicate with PC via WLAN: Connect the oscilloscope USB Host to your wireless network adapter, and make sure your local wireless network is normal.
  • Page 208 SDS1000X-E User Manual Return to the I/O SET menu Press the IP Set softkey to finish the IP configuration(see “To Set the LAN”) Use EasyScopeX or NI Vista to communicate with the oscilloscope. Figure 118 WIFI Setting Menu WWW.SIGLENT.COM...
  • Page 209: Web Server

    SDS1000X-E User Manual Web Server SDS1000X-E (only 4 channels scope supports this function) provides the web server function; you can access and control the oscilloscope using a web browser. Connect the oscilloscope to your LAN (or WLAN), then type the oscilloscope's IP address in the web browser.
  • Page 210: Update Firmware And Configuration

    SDS1000X-E User Manual Update Firmware and Configuration The firmware and configuration can be updated directly via USB flash driver. Do the following steps to update the firmware: Insert the USB flash driver which with the firmware and the configure files inside into the USB host interface on the front panel of the oscilloscope.
  • Page 211: Do Self-Test

    SDS1000X-E User Manual Do Self-Test Self-tests include screen test, keyboard test, and LED test. Self-tests used to test the screen, buttons, knobs and LED lights whether works well. Screen Test Press the Utility button on the front panel to enter the UTILITY function menu. Press the Next Page softkey to go to the second page of the UTILITY function menu.
  • Page 212: Keyboard Test

    SDS1000X-E User Manual Keyboard Test Keyboard test is used to test that if the keys or the knobs work well. Do the following steps to do keyboard test: Press the Utility button on the front panel to enter the UTILITY function menu. Press the Next Page softkey to go to the second page of the UTILITY function menu.
  • Page 213 SDS1000X-E User Manual Press the Next Page softkey to go to the third page of the UTILITY function menu. Press the Do Self Test softkey to enter the SELFTEST function menu. Press the LED Test softkey to enter the keyboard test interface, as the picture shown below.
  • Page 214: Screen Saver

    SDS1000X-E User Manual Screen Saver When the oscilloscope enters the idle state and holds for a certain period of time, the screen saver program will be enabled. Do the following steps to set the screen saver time: Press the Utility button on the front panel to enter the UTILITY function menu. Press the Next Page softkey to go to the second page of the UTILITY function menu.
  • Page 215: Reference Position

    SDS1000X-E User Manual Reference Position The reference position setting determines the physical point that the oscilloscope uses during vertical and horizontal scale changes. In some situations, it is more convenient to use a fixed position on the display. Press the Utility button on the front panel and then press the Reference Pos. softkey to enter the Reference POS menu.
  • Page 216: Option Management

    SDS1000X-E User Manual Option Management The SDS1000X-E provides multiple options to fulfill your measurement requirements. Please contact your SIGLENT sales representative or SIGLENT technical support to order the corresponding options. You can view the options currently installed on the oscilloscope or activate the newly purchased option license codes through this menu. Do the following steps to install the option on the oscilloscope: Press the Utility button on the front panel to enter the UTILITY function menu.
  • Page 217 SDS1000X-E User Manual Figure 126 Option Information WWW.SIGLENT.COM...
  • Page 218: Bode Plot Ii

    SDS1000X-E User Manual Bode Plot II The bode plot application for the SDS1000X-E (only 4 channels scope supports this function) controls an external arbitrary waveform generator(only Siglent’s arbitrary waveform generator can be supported) to sweep a sine wave across a range of frequencies while measuring the input to and output from a device under test (DUT).
  • Page 219 SDS1000X-E User Manual Connect the oscilloscope and the external AWG via LAN. If LAN is selected, press the Set IP softkey, and set the IP of AWG in the  pop-up dialog box. Press the Connection Test softkey to check the connection. ...
  • Page 220 SDS1000X-E User Manual Press the Load soft key to switch the load between 50Ω, 75Ω, 600Ω, Hi-Z. It  also can turn the Universal Knob to set the load value. Press the Set Channel softkey to enter the SET CHANNEL menu. Press the DUT Input softkey to select the corresponding input signal ...
  • Page 221 SDS1000X-E User Manual Figure 131 DATA Menu Press the List softkey repeatedly to turn the Bode plot data list on or off. After turning on the list, press the Scroll soft key and turn the Universal Knob to select the frequency point, as shown below. Figure 132 Bode Plot List On Press Save softkey (Recall softkey) to enable the bode plot save (recall) function.
  • Page 222: Example

    SDS1000X-E User Manual Example The following are examples to familiarize you with bode plot. Simple Sweep Operation  Vari-level Sweep Operation  Simple Sweep Operation Press Utility button on the front panel to enter the UTILITY function menu, and then press the Next Page soft key to enter the second page.
  • Page 223 SDS1000X-E User Manual Figure 136 Set Stimulus Menu Press Set Channel to enter Set Channel menu. In this example, set DUT Input to “CH1”, and DUT Output 1 to “CH2”. Other DUT Output remains “None”. Since we want to maximize measurement dynamic range, set Channel Gain to “Auto”. Then return to the Configure menu.
  • Page 224: Vari-Level Sweep Operation

    SDS1000X-E User Manual Vari-level Sweep Operation Press Utility button on the front panel to enter the UTILITY function menu, and then press the Next Page soft key to enter the second page. Press Bode Plot Ⅱ to enter the BODE PLOT function menu. Press Config to enter Configure menu. Press Source to enter Source menu to select the waveform generator.
  • Page 225 SDS1000X-E User Manual Figure 141 Set Vari-level Parameters Menu 10. The Set Sweep and Set Stimulus in Vari-level editor are similar to that in the Simple sweep mode, but they are independently configured and do not affect each other. These options in Vari-level mode do not have frequency and amplitude input because they are specified in the spreadsheet.
  • Page 226 SDS1000X-E User Manual Figure 143 Bode Plot Sweep Curve WWW.SIGLENT.COM...
  • Page 227: Search

    SDS1000X-E User Manual Search SDS1000X-E (only 4 channels scope supports this function)provides search function. This function can search for the events that users specify in the acquired data, the results are displayed with white triangle symbol. In the YT mode or the Roll mode with the acquisition in stop, the maximum search events number is 700.In the Roll mode with acquisition in run, the maximum search events number is unlimited.
  • Page 228: Results

    SDS1000X-E User Manual Limit Range includes four types: <=, >=, [--,--] and --][-- , Users can select the desired type and then input the time value. Pulse Polarity includes Positive and Negative Limit Range includes four types: <=, >=, [--,--] and --][-- , Users can select the desired type and then input the time value.
  • Page 229 SDS1000X-E User Manual Figure 146 Search in Stop When the acquisition is stop, “EVENT NUM: 4/7” means current event number/total events number, the current event is the closest event to the middle of the screen. WWW.SIGLENT.COM...
  • Page 230: Navigate

    SDS1000X-E User Manual Navigate SDS1000X-E (only 4 channels scope supports this function) provides three navigate type: Search Event, Time, History Frame. Time Navigate Press the Navigate on the front panel to enter the NAVIGATE function menu. Press the Type softkey In the NAVIGATE function menu, then select Time. There are two ways to navigate time.
  • Page 231: Search Event Navigate

    SDS1000X-E User Manual Search Event Navigate When the Search function is enabled and acquisitions are stopped, you can use the navigation controls to go to found search events Press the Navigate on the front panel to enter the NAVIGATE function menu. Press the Type in the NAVIGATE function menu, then select Search Event.
  • Page 232: History

    SDS1000X-E User Manual History The history function can record the waveforms of the input channels before press the Run/Stop button. In run state, the oscilloscope records input waveform continually; when fill up the memory (reach the maximal frame), the new frames will cover the old frames and keep the latest frames.
  • Page 233 SDS1000X-E User Manual the maximal frames, because the memory is not filled. So if you want to get the maximal frames, please wait for enough time for acquisition. The table shows the maximal frame according to the sampling rate and current sampling point’s number.
  • Page 234: Factory Setup

    SDS1000X-E User Manual Factory Setup Press Save/Recall function key, then press Save menu select To Default Key set the type to Factory Setup. Then press the Default button on the front to set the oscilloscope to the leave factory setup. Another way is press Save/Recall function key, then press Recall menu select Factory Default to recall.
  • Page 235: Troubleshooting

    SDS1000X-E User Manual Troubleshooting The commonly encountered failures and their solutions are listed below. When you encounter those problems, please solve them following the corresponding steps. If the problem remains still, please contact SIGLENT Company as soon as possible. The screen is still dark (no display) after power on: Check whether the power is correctly connected.
  • Page 236 SDS1000X-E User Manual to the middle or set the mode to “Auto”. Note: using AUTO could automatically finish the above setting. The display of waveform is ladder-like: The horizontal time base might be too low. Increase the horizontal time base to increase the horizontal resolution and improve the display.
  • Page 237 SDS1000X-E User Manual SDS1000X-E Series Digital Oscilloscope WWW.SIGLENT.COM...

Table of Contents