Installation location

A dry, well ventilated room is suitable as
an installation location. The installation
location should not be exposed to direct
sunlight and not placed near a heat
source, e.g. a cooker, radiator, etc. If
installation next to a heat source is
unavoidable, use a suitable insulating
plate or observe the following minimum
distances from the heat source:
3 cm to electric or gas cookers.
30 cm to an oil or coal-fired cooker.
The floor of the installation location must
not give way; if required, reinforce floor. If
the floor is uneven, compensate with
supports.
Distance from wall
When installing the appliance, ensure
that the door can be opened by 90°.

Fitting the wall spacer

Fit wall spacers to obtain the indicated
energy rating of the appliance.
A reduced wall gap will not restrict the
function of the appliance. The energy
rating may then increase slightly.
Distance to the back wall
The distance of 75 mm must not be
exceeded.

Aligning the appliance

Place the appliance in the designated
location and align.The appliance must be
level and stand securely on the floor. If
the floor is uneven, use the front height-
adjustable feet. Adjust the height-
adjustable feet with a spanner.
Note
The appliance must be vertical. Please
align it with a spirit level.
Observe ambient
temperature
and ventilation
Ambient temperature
The appliance is designed for a specific
climate class. Depending on the climate
class, the appliance can be operated at
the following temperatures.
The climate class can be found on the
rating plate. Fig. )
Climate class Permitted ambient
temperature
+10 °C to 32 °C
SN
+16 °C to 32 °C
N
ST
+16 °C to 38 °C
T
+16 °C to 43 °C
Note
The appliance is fully functional within
the room temperature limits of the
indicated climatic class. If an appliance
of climatic class SN is operated at colder
room temperatures, the appliance
will not be damaged up to a temperature
of +5 °C.