ERR O R
I S S UE
Fridge does not work
Poor cooling performance
Abnormal noise
Condensation
E1
Low Input Voltage
E2
Fan Fault
E3
Compressor Start Fault
E4
Compressor Operation Fault Check the input voltage to the fridge and restart
E5
Overheat of Controller
E6
NTC Open or Short Circuit
PA RT NO .
GROSS CAPACITY:
CLIMATIC CLASS:
RATED VOLTAGE - DC:
RATED CURRENT - DC:
PROTECTION LEVEL:
REFRIGERANT TYPE/AMOUNT:
FOAM VESICANT:
TEMPERATURE RANGE:
NET WEIGHT:
For further information or assistance please contact customer service on 1300 174 876
P O SS I B LE C A U SE
Check if power is connected properly (check plugs are securely positioned and
positive and negative not reversed)
Check power switch in ON
Check if cooling unit ventilation is not blocked or restricted
Check the fuse at the supply or contact service to have the internal fuse (located
within the cooling unit) checked
Check that the fridge is securely closed
Check if there is any damage to the fridge seals
Check if cooling unit ventilation is not blocked or restricted
Check the set temperature is adequate
Check if refrigerator is level
Check for vibration sources in surrounding objects
Check for loose items in the fridge
Water flow type noise is normal and not sign of any fault in the unit
It is normal for some condensation to form on the refrigerator surface when
humidity is more than 75%
Power cord was inserted into the cigarette socket before car starts - wait for car
engine to start before plugging in
Battery protection level setting is too high - adjust the protection setting or
change to a power source with a higher output voltage
Contact service to have the fan replaced
Shut down the fridge for 5 minutes and restart it - if it doesn't fix the issue, follow
the procedures for E1 error
Shut down the fridge for 5 minutes and check for cooling unit ventilation
restrictions or blockages
Contact service to have the NTC sensor checked
C F R 1 03 0XTM
35L
T/ST/N/SN
12V / 24V or 14.5V DC
Up to 6A
III
R134a - 34g
Cyclopentane
-20ºC to +10ºC
14KG