Drain Piping - Daikin FTL28UV16W1 Operation Manual

Hide thumbs Also See for FTL28UV16W1:
Table of Contents

Advertisement

WIRING
1) Strip wire ends (15mm).
2) Match wire colours with terminal numbers on indoor and outdoor
unit's terminal blocks and firmly screw wires to the corresponding
terminals with the screw.
3) Connect the earth wires to the corresponding terminals.
Attach the earth wire so that it is not connected to the fan motor connector.
4) Pull wires to make sure that they are securely latched up, then retain wires
with wire retainer.
5) Shape the wires so that the service lid fits securely, then close service lid.
Firmly fix the wires with
the terminal screws.
Indoor
unit
Capacity Class (kW)
Inter Unit wire (a)
Power supply wire (b)
Wire Standard
Circuit breaker size (c)
Power supply (d)
Note: Use 4-core 1.5 mm2 wire if wire is not included with the unit.
____________________________________
it,
WARNING
• Use a stabiliser if required by the voltage supply condition.
• Do not use tapped wires, extension cords, or starburst connections, as they may cause overheating, electrical shock, or fire.
• Do not use locally purchased electrical parts inside the product. (Do not branch the power for the drain pump, etc., from the
terminal block.) Doing so may cause electric shock or fire.

DRAIN PIPING

1) Connect the drain hose, as described right.
2) Remove the air filters and pour some water into the drain pan to check the water
flows smoothly.
3) When drain hose requires extension, obtain an extension hose commercially available.
Be sure to thermally insulate the indoor section of the extension hose.
4) When connecting a rigid polyvinyl chloride pipe (nominal diameter
13mm) directly to the drain hose attached to the indoor unit as with
embedded piping work, use any commercially available drain
socket (nominal diameter 13mm) as a joint.
5
INDOOR UNIT
Outdoor unit
Firmly fix the wires with
the terminal screws.
Power supply wire(b)
Circuit breaker 11 Earth leakage
( c)
circuit breaker
Earth
I
above 3. 7 and upto 7. 1
2.5-3.7
I
4-core, 1.0 mm
2
or more
4-core, 1.5 mm
3-core, 1.5 mm
2
or more
IS:694 or country specific standard.
I
15A or more
50Hz 230V~or Country specific
-i: -
Drain hose supplied
with the indoor unit
Terminal block
Power supply (d)
2
or more
20Aor more
The drain hose should
be inclined downward.
No trap is permitted.
Do not put the end
of the hose in water.
Heat insulation tube
(field supply)
rr=j
a:==) -
Co mmercially
Commercially
available drain
available rigid
socket (nominal
polyvinyl chloride
diameter 13mm)
pipe (nominal
diameter 13mm)
1_a1J _ 1•_N_•_- 4