Coleman Fyreknight Hyperflame 9966 Series Instructions For Use Manual

Camp stove

Advertisement

Quick Links

LPG Stoves
Instructions for use
9966 Series
* The griddles are only included for certain models.
Read these instructions for use carefully. Familiarise yourself with
the appliance before connecting it to a gas cylinder. Keep these
instructions for future reference.
This instruction manual contains important information necessary for
the proper assembly and safe use of the appliance. Follow all warnings
and instructions when using the appliance. If you have questions about
assembly, operation, servicing or repair of this product, please call
Coleman on 1800 224 350. Newell Australia Pty Ltd.
Gas cylinders shall be changed in a well-ventilated location, preferably
outside away from people and any sources of ignition, such as naked
flames, pilot flames, electric heaters / equipment. If there is a leak
on your appliance (smell of gas) and you cannot stop the gas flow,
immediately turn off the cylinder valve and remove the appliance to
a well-ventilated location away from any ignition source. Check for
leaks using soapy water. Do not try to detect leaks using a flame.
This appliance must only be serviced by an authorised person. Gas
cylinders must be stored outdoors in a well ventilated area out of the
reach of children, any indoor storage shall comply with AS/NZS 1596.
This appliance shall only be used with propane LPG Coleman
disposable gas cylinders certified to DOT-39 NRC 232/290 M1110.
OR refillable Universal LPG cylinder certified to AS2030/AS2469 &
Coleman hose assembly. IT MAY BE HAZARDOUS TO ATTEMPT TO
FIT OTHER TYPES OF GAS CONTAINERS. DO NOT USE ADAPTORS.
Not suitable for installation or connection to a reticulated gas supply.
CAUTION: accessible parts may be very hot. Keep young children
away, USE OUTDOORS ONLY. Must only be operated on a horizontal
surface. Not suitable for marine environments. Do not modify this
appliance.
INSTASTART™ Electronic Ignition
Standard Ignition
Camp Stove
IMPORTANT

Advertisement

Table of Contents
loading

Summary of Contents for Coleman Fyreknight Hyperflame 9966 Series

  • Page 1 AS/NZS 1596. This appliance shall only be used with propane LPG Coleman disposable gas cylinders certified to DOT-39 NRC 232/290 M1110.
  • Page 2: For Your Safety

    FOR YOUR WARNING FIRE OR EXPLOSION SAFETY HAZARD If you smell gas: Do not store or use gasoline or other 1. Do not attempt to flammable vapors and light appliance. liquids in the vicinity 2. Make sure appliance of this or any other is in the off position.
  • Page 3: California Proposition

    CO if used and as an instruction manual or labels, contact maintained in accordance with all The Coleman Company, Inc. warnings and instructions. Do not block air flow into or out of the stove. This manual contains important •...
  • Page 4: Service Safety

    U.S. Department of Transportation or Transport Canada, CAN/CSA B339. OR refillable Universal LPG cylinder certified WARNING to AS2030/AS2469 & Coleman hose assembly. Only use the hose assembly as supplied with this appliance for connection to the cylinder – DO NOT USE ADAPTORS.
  • Page 5 NOTE: The handle can’t be pulled Do not use this griddle on a down fully. campfire or other open fire. Use this griddle only on the Coleman ® stove for which it was designed. 6. Control Knob Identification (Fig. 6) Fig.
  • Page 6: Leak Check

    8. Screw regulator into stove hand tight. To Light (Fig. 8) 9. Remove plastic cap from top of LPG bottle and screw LPG bottle into DANGER regulator hand tight. (Fig. 9) EXPLOSION - FIRE HAZARD LPG is heavier than air and Fig.
  • Page 7: To Turn Off

    Match Lighting 1. Set stove on sturdy, flat surface. For outdoor use only. 2. Hold lighted match near burner and open burner valve. (Fig. 13) 3. Repeat for both burners. Fig. 16 Fig. 17 Cleaning the Griddle (if included) 1. Make sure stove and griddle are cool.
  • Page 8 Use Outdoors Only This appliance shall only be used in an above ground open air situation with natural ventilation, without stagnant areas, where gas leakage and products of combustion are rapidly dispersed by wind and natural convection. Any enclosure in which the appliance is used shall comply with one of the following: (A) An enclosure with walls on all sides, but with no overhead cover.
  • Page 9: Things You Should Know

    -0.4°F cover for location of your nearest Coleman Service Center. (-18°C). If not completely satisfied with the performance of this product, 1. For storage or transport, the...
  • Page 10: Replacement Parts List

    Coleman will, depending on the circumstances, refund, repair or replace this product or any component of the product found to be defective during the warranty period.
  • Page 11 MAKING A WARRANTY CLAIM - RETURN TO COLEMAN FOR REPAIR Take the product to an authorised Coleman retailer or Coleman service centre as soon as the warranty claim arises. You may locate the nearest authorised Coleman retailer or Coleman service centre by visiting www.colemanaustralia.com.au or calling 1800...
  • Page 12 Newell Australia Pty Ltd Caribbean Park Level 3, 35 Dalmore Drive Scoresby, VIC 3179 Australia Telephone: 1800 224 350 Email: customerservice@colemanaust.com.au www.colemanaustralia.com.au © 2023 The Coleman Company, Inc. All rights reserved. Coleman ® registered trademarks of The Coleman Company, Inc. 4010041866 (ECN20067183-C)