Technical Specifications - Lincoln Electric CITOCUT 25i Operator's Manual

Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 4

Technical Specifications

CITOCUT 25i
Input Voltage
230 V ±10%
Single Phase
Duty Cycle
(Based on a 10 min. period)
100%
60%
35%
Cutting Current Range
10 - 25 A
Required Inlet Flow Rate
80 ±20% l/min @ 5.0bar
Fuse (delayed) or Circuit Breaker
("D" characteristic) Size
16 A
Height
385 mm
Operating Temperature
-10°C to +40°C
English
NAME
Input Power at Rated Output
2 kW @ 100% Duty Cycle
2.5 kW @ 60% Duty Cycle
3 kW @ 35% Duty Cycle
RATED OUTPUT AT 40°C
OUTPUT RANGE
Maximum Open Circuit Voltage
EXTERNAL INLET COMPRESSED AIR
RECOMMENDED INPUT CABLE AND FUSE SIZES
(Included with Machine)
SCHUKO 16A / 250V
PHYSICAL DIMENSIONS
Width
215 mm
INPUT
Output Current
15 A
20 A
25 A
500 Vdc
Type of Plug
Length
(case only,without torch)
480 mm
1
INDEX
W000404424
EMC Class
A
Output Voltage
86 Vdc
88 Vdc
90 Vdc
Pilot Arc Current
12 A
Required Inlet Pressure
6.0bar - 7.5bar
Input Power Cable
3 x 1.5 mm
Weight
18 – 18.5 kg
Storage Temperature
-10°C to +40°C
Frequency
50Hz
2
English

Advertisement

Table of Contents
loading

This manual is also suitable for:

W000404424

Table of Contents