HARDKORR HKPPWRHUB25 User Manual page 17

12v control hub with dc-dc charger
Table of Contents

Advertisement

FAULT CODES
When over/under-voltage, over-current or
over-temperature occurs, the buzzer sounds 0.5
seconds on and 0.5 seconds off alternatively.
Press
to mute the buzzer and return to the
normal status.
OUTPUT - CIGARETTE SOCKETS
The 12V control hub contains three cigarette sockets to allow you to plug in common appliances like
camp-fridges, inflation devices and lighting. The two left-most sockets are fused in tandem with a single
15A blade fuse. The right-most socket is fused on its own with a 15A blade fuse.
The 12Vcontrol hub contains an array of different types of USB ports for various uses like charging
phones and laptops, as well as using any small device that requires a USB connection. These are fused in
tandem with a single 15A blade fuse allowing for a maxumim combined current of 15A.
The 12V control hub contains two Anderson plug outputs. These are each fused with a 30A blade fuse.
The 12V control hub contains six rocker switches to provide direct switched control of your camp
accessories. These are fused with a 20A blade fuse in banks of two, allowing for a maximum combined
current of 20A between each pair of switches.
The 12V control hub contains an externally accessible fuse box housing the aforementioned blade fuses.
These are standard blade fuses and the bottom two fuses are spares that can be swapped out in the
event of a blown fuse. If you encounter a blown fuse, there is an indicator LED next to each socket that
will show you which needs replacing.
OUTPUT - USB
OUTPUT - ANDERSON
ROCKER SWITCHES
FUSE BOX
OPERATION
CODE
F1
Input over-voltage.
F2
Input under-voltage.
F3
Input over-current.
F4
Over-temperature.
14
FAULT

Advertisement

Table of Contents
loading

This manual is also suitable for:

Hkppwrhub40

Table of Contents