MG Mini-M M2EXV Operating Manual
MG Mini-M M2EXV Operating Manual

MG Mini-M M2EXV Operating Manual

Signal transmitter pc programmable

Advertisement

Quick Links

OPERATING MANUAL
SIGNAL TRANSMITTER
BEFORE USE .... ........................................................................................................... 2
POINTS OF CAUTION ...................................................................................................... 2
COMPONENT IDENTIFICATION .......................................................................................... 2
INSTALLATION ............................................................................................................. 3
TERMINAL CONNECTIONS ............................................................................................... 3
EXTERNAL VIEWS ......................................................................................................... 4
DIP SWITCH ................................................................................................................ 4
SCREEN DISPLAY .......................................................................................................... 5
PROGRAMMING ........................................................................................................... 6
ERROR MESSAGES ...................................................................................................... 18
WIRING INSTRUCTIONS ................................................................................................ 18
CHECKING ................................................................................................................ 18
MAINTENANCE ........................................................................................................... 19
LIGHTNING SURGE PROTECTION ..................................................................................... 19
MG CO., LTD. www.mgco.jp
5-2-55 Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN
(PC programmable)
CONTENTS
Mini-M
M2EXV
MODEL
EM-5133-B Rev.7 P. 1 / 19

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Mini-M M2EXV and is the answer not in the manual?

Questions and answers

Summary of Contents for MG Mini-M M2EXV

  • Page 1: Table Of Contents

    SCREEN DISPLAY ......................5 PROGRAMMING ......................6 ERROR MESSAGES ...................... 18 WIRING INSTRUCTIONS ....................18 CHECKING ........................ 18 MAINTENANCE ......................19 LIGHTNING SURGE PROTECTION ..................19 EM-5133-B Rev.7 P. 1 / 19 MG CO., LTD. www.mgco.jp 5-2-55 Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN...
  • Page 2: Before Use

    ≤ 6.5VA at 200V AC ≤ 8.5VA at 264V AC 24V DC rating: 24V ±10%, ≤ 2.3W 110V DC rating: 85 – 150V, ≤ 2.3W EM-5133-B Rev.7 P. 2 / 19 MG CO., LTD. www.mgco.jp 5-2-55 Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN...
  • Page 3: Installation

    • When mounting, no extra space is needed between units. ■ CONNECTION DIAGRAM Input Current OUTPUT – – – Input Voltage U(+) POWER JACK CONFIGURATOR V(–) EM-5133-B Rev.7 P. 3 / 19 MG CO., LTD. www.mgco.jp 5-2-55 Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN...
  • Page 4: External Views

    0 – 20 mA -5 – +5 V -10 – +10 V CAUTION: DO NOT set DIP switches while power is supplied. Otherwise, the unit may fail. EM-5133-B Rev.7 P. 4 / 19 MG CO., LTD. www.mgco.jp 5-2-55 Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN...
  • Page 5: Screen Display

    Pressing Mode, Set, Up, or Down button or occurrence of an error restores the display from display off. Set to ‘0’ to keep the display ‘always on’. EM-5133-B Rev.7 P. 5 / 19 MG CO., LTD. www.mgco.jp 5-2-55 Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN...
  • Page 6: Programming

    Hold down Mode Button for ≥ 2 seconds Hold down Mode Button for ≥ 8 seconds Linearization Mode Hold down Mode Button for ≥ 2 seconds EM-5133-B Rev.7 P. 6 / 19 MG CO., LTD. www.mgco.jp 5-2-55 Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN...
  • Page 7 ‘Unlock’. To enable lockout setting again, set ‘Lock’. Even when lockout setting is enabled, it is available to confirm the each setting value. ‘DATA (Locked)’ is indicated in that case. EM-5133-B Rev.7 P. 7 / 19 MG CO., LTD. www.mgco.jp 5-2-55 Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN...
  • Page 8 100 % Output Scaling Down oooooo / ooooo.o oooo.oo / ooo.ooo Output Decimal Point oo.oooo / o.ooooo Down Cancel / Set Loop Test Down EM-5133-B Rev.7 P. 8 / 19 MG CO., LTD. www.mgco.jp 5-2-55 Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN...
  • Page 9 Output decimal point No decimal point — 2 places of decimals The number of decimal places : 1 – 5, Loop test -5.00 – 105.00 Cancel EM-5133-B Rev.7 P. 9 / 19 MG CO., LTD. www.mgco.jp 5-2-55 Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN...
  • Page 10 0.00 [21] 100 % output scaling Set the display value of [19] 100 % output setting. SETTING RANGE INITIAL VALUE -99999 – 999999 100.00 EM-5133-B Rev.7 P. 10 / 19 MG CO., LTD. www.mgco.jp 5-2-55 Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN...
  • Page 11 *1. While loop test is performing, actual input is disregarded. While loop test is performing and ‘Display timeout’ is enabled to display off, return to the display on by pressing a front button. EM-5133-B Rev.7 P. 11 / 19 MG CO., LTD. www.mgco.jp 5-2-55 Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN...
  • Page 12 100.000 Output Zero fine adjust -5.000 – 5.000 0.000 Output Span fine adjust 95.000 – 105.000 100.000 Lockout setting Lock / Unlock — Lock EM-5133-B Rev.7 P. 12 / 19 MG CO., LTD. www.mgco.jp 5-2-55 Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN...
  • Page 13 0 − 9 A − Z a − z ! ” # $ % & ’ ( ) = - + * ^ | @ ` [ ] { } ; : < > ? _ , . / Initial value: % EM-5133-B Rev.7 P. 13 / 19 MG CO., LTD. www.mgco.jp 5-2-55 Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN...
  • Page 14 0 (always on), 1 – 60 min. Reset all settings OFF / RESET — Version indication — — — Lockout setting Lock / Unlock — Lock EM-5133-B Rev.7 P. 14 / 19 MG CO., LTD. www.mgco.jp 5-2-55 Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN...
  • Page 15 It is available to set the range between 0 – 60 minutes. Set ‘0’ to display ‘always on’. When error is occurred at display off, the display returns from off. Initial value: 10 EM-5133-B Rev.7 P. 15 / 19 MG CO., LTD. www.mgco.jp 5-2-55 Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN...
  • Page 16 2 – 111 — 167 – Table -5.00 – 105.00 X001 -5.00 Y001 -5.00 X002 105.00 Y002 105.00 Lockout setting Lock / Unlock — Lock EM-5133-B Rev.7 P. 16 / 19 MG CO., LTD. www.mgco.jp 5-2-55 Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN...
  • Page 17 X. These two data are linearly interpolated and Y is obtained and output it. Yn+1 Output % Input % Xn+1 EM-5133-B Rev.7 P. 17 / 19 MG CO., LTD. www.mgco.jp 5-2-55 Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN...
  • Page 18: Error Messages

    Recommended manufacturer: Japan Solderless Terminal 5) Output: Check that the load resistance meets the de- scribed specifications. MFG.Co.Ltd, Nichifu Co.,ltd 3.3 (.13) max mm (inch) EM-5133-B Rev.7 P. 18 / 19 MG CO., LTD. www.mgco.jp 5-2-55 Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN...
  • Page 19: Maintenance

    LIGHTNING SURGE PROTECTION We offer a series of lightning surge protector for protec- tion against induced lightning surges. Please contact us to choose appropriate models. EM-5133-B Rev.7 P. 19 / 19 MG CO., LTD. www.mgco.jp 5-2-55 Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN...