Precautions for Installation
・ Do not install or use the product at the following places. It may lower
accuracy or cause a failure.
A place where;
The receiving part is directly exposed to sunlight or ambient light. (Use a tool like
Water, oil, agent or organic solvent scatters or attaches to the product.
The product receives too much vibration or shock.
・ Install the product away from noise generating devices such as high
voltage cable, power line or inverter drive motor. Noise may cause a
malfunction.
・ Do not pull or apply excess power to a cable. It may damage the
product.
Operating Precautions
・ Do not use the product just after turning on. A warm-up operation over 30
minutes is required before use.
・ The sensor performance may depend on the individual units.
・ Wipe off dirt on the cover (glass) of the emitting/receiving parts using a soft
cloth etc., at every operation since it may cause incorrect detection.
Ramco Innovations
800-280-6933
5
CD5 Sensor Head
www.optex-ramco.com