OPTEX FA FASTUS CD22 Series Quick Start Manual

Compact laser displacement sensor

Advertisement

Quick Links

Compact laser displacement sensor
CD22
Series
Quick Start
Ramco Innovations
1207 Maple Street West Des Moines, IA
50265 Phone 800-280-6933 wwww.ramcoi.com
This quick start explains the basic settings
required to measure and detect objects.
Setting the analog output
Use this procedure to set the points at which to generate the
minimum and maximum analog output and the directions for
increasing and decreasing this output.
Setting the control output thresholds (the switching references)
Use this procedure to set the thresholds used as the references for
switching control output ON and OFF.
Selecting the teach mode (threshold setting type)
1
2
Executing the teach (setting the thresholds)
Fine adjustment the thresholds
3
For information not included in this guide (such as installation, wiring,
specifications, and a list of the functions), see the instruction manual
included with the product or the OPTEX FA website.
Setting the analog output
Use this procedure to set the output range of the analog output
and the directions for increasing and decreasing this output.
Displayed distance
On the CD22 series, the center point of the measurement range is displayed
as "0".
Distances further away from the sensor than the center point are added to
the value of the center point and are displayed as positive numbers.
Distances closer to the sensor than the center point are subtracted from the
value of the center point and are displayed as negative numbers.
Minimum
distance
[Displayed
values]
−5.000 mm
CD22-15x
(10 mm)
CD22-35x
−15.00 mm
(20 mm)
CD22-100x
−50.00 mm
(50 mm)
"9999" is displayed when the object is outside the measurement
range or cannot be measured.
Analog output type only
Analog output type only
Center point of
Maximum
measurement range
distance
Subtracted
Added
"0"
0.000 mm
5.000 mm
(15 mm)
(20 mm)
0.00 mm
15.00 mm
(35 mm)
(50 mm)
0.00 mm
50.00 mm
(100 mm)
(150 mm)
( ): Measurement distance
00-2310
Setting the analog output
Use this procedure to set the sensing distances at which to generate the
minimum (0V/4mA) and maximum (10V/20mA) analog output.
As an example, this section explains how to set the analog output on the
CD22-15x.
Measurement range
(displayed value)
CD22-15x
Output voltage
/current
10V/20 mA
0V/4 mA
Canceling setup
Press [ZERO RUN]. The sensor returns to [RUN] mode.
(1) In [RUN] mode (with the measured
value displayed), press [SET].
(2) [MENU] appears. Press [SET].
(3) The minimum analog output
appears. Press [SET].
• Voltage output type:
[0V]
0V
(4) The present minimum blinks.
Use the [+] or [−] key to enter the
distance at which to generate the
minimum analog output.
<Reference> Default minimum values
Model name
CD22-15x
CD22-35x
CD22-100x
1
Ramco Innovations www.ramcoi.com
Minimum
Center point
distance
10 mm
15 mm
(−5.000 mm)
(0.000 mm)
Analog output
Point of minimum
Point of maximum
analog output
analog output
e.g.) Analog voltage output type
• Current output type:
[4mA]
4mA
-2. 0 00
Minimum (0V/4mA)
The negative sign is displayed here.
−5.000 mm
As an example, the value is set to
[−2.000] here.
−15.000 mm
At a distance of [−2.000], the
minimum analog output ([0V] or
−50.00 mm
[4mA]) is generated.
Maximum
distance
20 mm
(5.000 mm)
Distance
0. 2 34
MEnu
0V

Advertisement

loading

Summary of Contents for OPTEX FA FASTUS CD22 Series

  • Page 1 For information not included in this guide (such as installation, wiring, specifications, and a list of the functions), see the instruction manual included with the product or the OPTEX FA website. Setting the analog output (2) [MENU] appears. Press [SET].
  • Page 2 Ramco Innovations www.ramcoi.com Setting the control output (5) Enter the distance and press [SET]. e.g.) Analog voltage output type The minimum is confirmed, and the thresholds sensor returns to the previous screen. • Voltage output • Current output type: (the switching references) type: [0V] [4mA] Use teach mode to set the thresholds used as the references for...
  • Page 3 Ramco Innovations www.ramcoi.com Selecting the teach mode Executing the teach mode Select the teach mode before executing teach. Prepare the environment and the object to use for the detection conditions, and then execute the teach mode. Canceling setup This section uses the display of the CD22-15x type. Press [ZERO RUN].
  • Page 4 Ramco Innovations www.ramcoi.com Executing 1-point teach Executing FGS2 teach FG52 Before executing the teach mode Before executing the teach mode Select 1-point teach in “1. Selecting the teach mode”. Select FGS teach mode in “1. Selecting the teach mode”. FG52 (1) In [RUN] mode (with the Canceling setup measured value displayed),...
  • Page 5 Ramco Innovations www.ramcoi.com Fine adjustment the thresholds (entering numeric values) (9) Press [SET]. The far-side threshold appears. 5. 6 78 You can fine-adjust the thresholds set in teach mode (the distance to the center of the detection range for FGS2 teach) by entering numeric values. The distances set here are from the center of the measurement range.
  • Page 6 Ramco Innovations www.ramcoi.com (6) Use the [+] or [−] key to set the (7) Press [SET]. threshold. [FGS2] appears on the screen 6. 0 00 FG52 As an example, the value is set again. to [6.000] here. (7) Press [SET]. ■...

This manual is also suitable for:

Fastus cd22-15xFastus cd22-35xFastus cd22-100x