PROCEDURE
LETTER
Isolate the high voltage rectifier assembly from the HV circuit. The asymmetric can be tested using an
ohmmeter set to its highest range across the terminals A+B of the asymmetric rectifier and note the
reading obtained. Reverse the meter leads and note this second reading. If an open circuit is indicated
in both direction then the asymmetric rectifier is good. If an asymmetric rectifier is shorted in either
direction, then the asymmetric rectifier is probably faulty and must be replaced with high voltage rectifier.
When the asymmetric rectifier is defective, check whether magnetron, high voltage rectifier, high voltage
wire or filament winding of the high voltage transformer is shorted.
CARRY OUT 4R CHECKS
NOTE: FOR MEASUREMENT OF THE RESISTANCE OF THE RECTIFIER, THE BATTERIES OF THE
D
HIGH VOLTAGE CAPACITOR TEST
CARRY OUT 3D CHECKS
A. Isolate the high voltage capacitor from the circuit.
B. Continuity check must be carried out with measuring instrument which is set to the highest resistance
range.
C. A normal capacitor shows continuity for a short time (kick) and then a resistance of about 10MΩ after
it has been charged.
D. A short-circuited capacitor shows continuity all the time.
E. An open capacitor constantly shows a resistance about 10 MΩ because of its internal 10MΩ
resistance.
F. When the internal wire is opened in the high voltage capacitor shows an infinite resistance.
G. The resistance across all the terminals and the chassis must be infinite when the capacitor is normal.
If incorrect reading are obtained, the high voltage capacitor must be replaced.
CARRY OUT 4R CHECKS
E
SWITCH TEST
Isolate the switch to be tested and using an ohmmeter check between the terminals as described in the
following table.
CARRY OUT 3D CHECKS
COM; Common terminal, NO; Normally open terminal NC; Normally close terminal
S.C.; Short, O.C.; Open circuit
If incorrect readings are obtained, make the necessary switch or replace the switch.
CARRY OUT 4R CHECKS.
F
THERMAL CUT OUT TEST
CARRY OUT 3D CHECKS
Disconnect the leads from the terminals of the thermal cut-out. Then using an ohmmeter, make a
continuity test across the two terminals as described below.
CARRY OUT 4R CHECKS
Temperature of "ON" condition (closed circuit). .......................................... This is not resetable type
Temperature of "OFF" condition (open circuit). .............................................................. Above 125°C
Indication of ohmmeter (When room temperature is approx. 20°C.) ............................ Closed circuit
If incorrect readings are obtained, replace the thermal cut-out.
An open circuit thermal cut-out (MG) indicates that the magnetron has overheated, this may be due to
restricted ventilation, cooling fan failure or a fault condition within the magnetron or HV circuit.
TEST PROCEDURES (CONT'D)
MEASURING INSTRUMENT MUST HAVE A VOLTAGE AT LEAST 6 VOLTS, BECAUSE
OTHERWISE AN INFINITE RESISTANCE MIGHT BE SHOWN IN BOTH DIRECTIONS.
Table: Terminal Connection of Switch
Plunger Operation
Released
Depressed
COMPONENT TEST
COM to NO
COM to NC
O.C.
S.C.
S.C.
O.C.
11
R-5L16