TABLE OF CONTENTS Important Safety Information…...2 Feature Description…………………………….……………..3 Installation Instruction………………………………………..6 Use and Temperature Control…………..…………………10 Care Guide……………………………………………………12 Troubleshooting……………………………………………..13 Customer Support……………………………………………15 Warranty……………………………………………………….16 - 1 -...
Feature Description • The WINEMATE ducted cooling system is designed and used to provide a stable temperature between 55~65 °F for a properly insulated room at a normal environment. • The wine room space will maintain humidity of 50~70% RH even when the environment becomes dry or humid.
Installation Instruction 1. Location • WINEMATE ducted system is shipped ready for use • Place the unit in a properly ventilated location. If it is not, heat exhausted by the condensing unit will build up and the cooling system will not operate properly.
Page 8
4. Electrical Wiring • We strongly recommend against the use of an extension cord. However, if you still select to use an extension cord, it is absolutely necessary that it is a UL LISTED 3-wire grounding type appliance extension cord. The marked rating of the extension cord should be 115 V, 20 A.
Use & Temperature Control 1. Temperature Setting • Set the temperature at 55 • On initial start-up, the time required to reach the desired temperature will vary, depending on the quantity of bottles, temperature setting and surrounding temperature. • Allow 24 hours to stabilize the temperature for each new temperature setting operation 2.
Page 12
1) Set Point Rotate the circular selector in correspondence with the arrow placed nearby. The selector represents -33°F to 50°F (-35°C to +10°C) for low temperature models, and 14°F to 68°F (-10°C to +20°C) for medium temperature models. “10” is the coldest setting, “1”...
In general, always unplug system or disconnect power while doing care. 1. Coil Cleaning • Clean the condenser coil regularly. Coil may need to be cleaned at least every 6 months. • Unplug the system or disconnect power. • Use a condenser brush or a vacuum cleaner with an extended attachment to clean the coil when it is dusty or dirty.
This Troubleshooting Chart is not prepared to replace the training required for a professional refrigeration service person, not is it comprehensive Complaint Possible Causes 1. Unit not running a. Power cord unplugged b. No power to unit c. Temperature setting high d.
Page 15
g. Low voltage h. Operating 60 Hz unit at 50Hz Sealed system problem Undercharge or overcharge 7. House circuit tripping a. Incorrect fuse or breaker b. Incorrect wirings c. Failed components 8. Noisy operation a. Mounting area not firm b. Loose parts c.
Customer Support If you still have problems, please contact us at: Vinotemp International 17631 South Susana Road Rancho Dominguez, CA 90221 Tel: (310) 886-3332 Fax: (310) 886-3310 Email: info@vinotemp.com - 15 -...
BTU/H. While every effort has been made to provide accurate guidelines, VINOTEMP can not warranty its units to cool a particular enclosure. In case of failure, VINOTEMP cooling units must be repaired by the factory or its authorized agent. Repairs or modifications made by anyone else will void the warranty.
Page 18
VINOTEMP will, at its discretion, repair or replace the unit and return it free of charge to the original retail customer. If the unit is found to be in good working order, or beyond the initial twelve month period, it will be returned freight collect.