Connect-Key K 30 Rf; Electrical Connection - Bosch Compress Hybrid 3400i AW Installation Instructions Manual

Indoor unit for air to water heat pumps
Table of Contents

Advertisement

5.7.6

Connect-Key K 30 RF

Connect-Key K 30 RF is a WLAN communication module for controlling
and monitoring your heating system remotely. It is used as an interface
between the heating system and the Internet.
For further information on how to use and install the Connect-Key K 30
RF, please read the installation manual of the accessory.
A WLAN router, internet connection and the Bosch HomeCom Easy app
are required to use this product.
Installation on the wall:
Fig. 27 Placing the Connect-Key K 30 RF
When installing the holder for the Connect-Key K 30 RF on the wall:
1. Find a place next to the indoor unit that has sufficient signal quality to
communicate to the WLAN router.
2. Drill the holes to fix the bracket on the wall. For that, use a suitable
drill bit.
3. Screw on the bracket firmly to the wall.
The holder may also be placed on the side cover of the indoor unit using
the holder's incorporated magnet.
Compress Hybrid 3400i AW – 6721861825 (2023/08)
6
Risk to life from electric shock!
Touching live electrical parts can cause an electric shock.
▶ Before working on electrical parts, disconnect all phases of the
power supply (fuse/circuit breaker) and lock the isolator switch to
prevent unintentional reconnection.
Danger to life from electric current!
Incorrectly connected electrical cables can result in faulty operation with
potentially dangerous consequences.
▶ When making the electrical connections, refer to the connection
diagrams for the individual devices and components.
▶ When performing maintenance, label all power cables before
disconnecting them.
NOTICE
Material damage if the maximum current consumption is exceeded!
Short-term high (start-up) currents can can damage electrical
components.
▶ When connecting external components to the control unit, make sure
that the sum of the individual power consumption (consider the
power consumption of the boiler) does not exceed the maximum
0010039342-001
current consumption (control unit data plate).
Note the following when making electrical connections:
▶ Electrical work on heating systems must only be carried out by
qualified electricians. If you are not suitably qualified, ask a licensed
heating contractor/electrician to establish the electrical connection.
▶ Make sure that all system components are earthed or connected to
the equipotential bonding (protective earth is a constituent part of
the control unit used).
▶ Observe all local regulations!
Connect cables as shown in the connection diagrams (Chapter 12.4,
page 40).

Electrical connection

WARNING
WARNING
Electrical connection
19