PROFESSIONAL HOOD DATA
DESCRIPTION
10" HIGH VWH WALL HOODS
24"W.
30"W.
36"W.
18" HIGH VWH WALL HOODS
24"W.
30" AND 36"W.
42"W.
48" AND 54"W.
60" AND 66"W.
18" HIGH ISLAND VIH HOODS
36"W.
42"W.
54"W.
66"W.
18" HIGH VCWH CHIMNEY WALL HOODS
30" AND 36"W.
42"W.
48" AND 54"W.
60" AND 66"W.
18" HIGH VCIH CHIMNEY ISLAND HOODS
36"W.
42"W.
54"W.
66"W.
VBCV CUSTOM VENTILATOR SYSTEMS - FOR WALL
HOODS
30" AND 36"W.
42"W.
48" AND 54"W.
60" AND 66"W.
18" HIGH CHIMNEY ISLAND VICV HOODS
36"W.
42"W.
54"W.
66"W.
PROPER INSTALLATION/DUCTING IS EXTREMELY IMPORTANT TO ENSURE MAXIMUM PERFORMANCE FROM ANY VENTILATION PRODUCT
• ALL CFMS STATED BASED ON TESTS WITH .1 STATIC PRESSURE: WITHOUT APPLYING STATIC PRESSURE (SOME
BRANDS CONSCIOUSLY DO NOT), CFM COULD BE GREATLY OVERSTATED.
• DUCT RUN LENGTH IS FOR GENERAL REFERENCE ONLY; FOR LONGER DUCT RUNS, INCREASE DUCT SIZE AND CONTACT A
QUALIFIED AND TRAINED INSTALLER.
• STRAIGHT RUNS AND GRADUAL TURNS ARE BEST; FOR EXAMPLE, EACH 90
(1.52-3.05CM) OF STRAIGHT RUN.
• NEVER USE FLEXIBLE DUCT; IT CREATES BACK PRESSURE/AIR TURBULENCE AND GREATLY REDUCES PERFORMANCE.
• PROPER PERFORMANCE IS DEPENDENT UPON PROPER DUCTING; MAKE SURE THAT A QUALIFIED AND TRAINED INSTALLER
IS USED.
• CHECK WITH A QUALIFIED AND TRAINED INSTALLER OR LOCAL CODES FOR MAKEUP AIR REQUIREMENTS, IF ANY.
• MAX. AMP RATING FOR HOODS INCLUDES RECOMMENDED VENTILATOR KIT RATING; ALL PRODUCTS MUST BE HARD
WIRED DIRECT WITH 2-WIRE WITH GROUND.
• A 1200 OR 1500 CFM (IF APPLICABLE) VENTILATOR KIT SHOULD BE USED WHEN INSTALLED OVER RANGE/RANGETOPS
WITH GAS CHAR-GRILL.
HEAT
HALOGEN
FILTERS
LAMPS
LIGHTS
2
N/A
2
2
N/A
2
2
N/A
2
2
1
2
2
1
2
2
1
2
3
2
3
4
2
4
4
N/A
4
4
N/A
4
6
N/A
6
8
N/A
8
2
1
2
2
1
2
3
2
3
4
2
4
4
N/A
4
4
N/A
4
6
N/A
6
8
N/A
8
2
1
2
2
1
3
3
2
3
4
2
4
4
N/A
4
4
N/A
4
6
N/A
6
8
N/A
8
RECOMMENDED CFM
460 CFM INTERIOR STANDARD MAX.
DUCT RUN 50' (15.2 CM)
(7 " ROUND DUCT)
VIV300/VIV600/VEV900/VEV1200
VIV300/VIV600/VIV1200/VEV900/VEV1200
VIV600/VIV1200/VEV900/VEV1200
VIV1200/VEV1200/VEV1500
VIV1200/VEV1200/VEV1500
VIV600/VEV900/VEV1200
VIV600/VIV1200/VEV900/VEV1200/VEV1500
VIV1200/VEV1200/VEV1500
VIV1200/VEV1200/VEV1500
DIV300/DIV600/DEV900/DEV1200
DIV600/DEV900/DEV1200
DIV1200/DEV1200/DEV1500
DIV1200/DEV1200/DEV1500
DIV600/DEV900/DEV1200
DIV600/DEV900/DEV1200/DEV1500
DIV1200/DEV1200/DEV1500
DIV1200/DEV1200/DEV1500
VIV300/VIV600/VIV1200/VEV900/VEV1200
VIV600/VIV1200/VEV900/VEV1200
VIV1200/VEV1200/VEV1500
VIV1200/VEV1200/VEV1500
VIV600/VEV900/VEV1200
VIV600/VIV1200/VEV900/VEV1200/VEV1500
VIV1200/VEV1200/VEV1500
VIV1200/VEV1200/VEV1500
105
120 VAC/60 HZ MAX
5.0/6.2/8.7/8.7/6.1
5.0/6.2/8.7/8.7/6.1
4.9/7.4/7.4/4.8/5.5
5.0/6.2/8.7/8.7/6.1
4.9/7.4/7.4/4.8/5.5
ELBOW IS EQUIVALENT TO 5-10 FEET
0
AMPS
5.6
5.6
5.6
6.2/8.7/8.7/6.1
11.1/8.4/9.1
11.5/8.8/9.5
4.9/7.4/4.7
8.2/5.5/6.2
9.0/6.3/7.1
3.9/6.0/8.7/6.0
6.0/8.7/6.0
11.5/8.5/9.2
11.9/8.9/9.2
3.9/6.6/3.9
4.7/7.4/4.8/5.5
8.6/5.6/6.4
9.5/6.5/7.3
6.2/8.7/8.7/6.1
11.1/8.4/9.1
11.5/8.8/9.5
4.9/7.4/4.7
8.2/5.5/6.2
9.0/6.3/7.1

Hide quick links: