Display Messages; General Function Information - Rehau NEA HCT 24 V User Instructions And Quick Installation Manual

Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 36

Display messages

A
B-G
A
Frost protection is active
B
Er 1 – Remote temperature sensor out of sensor
range
C
Er 2 – Broken floor sensor
D
Er 3 – Shorted floor sensor
E
Er 4 – Room temperature out of sensor range
F
Er 5 – Interruption of room temperature probe
G
Er 6 – Short circuit of room temperature probe
R
Frost protection display will remain
until any key is pressed

General function information

Valve protection
To protect the valves the output is turned on
for 5 minutes in every week This function
stops the valve from getting stuck due to
long periods of inactivity
Pulse width modulation
Room temperature control is achieved by
opening and closing the circuit control
valves for defined times The opening time
of the valves is determined by the required
energy supply
PI control
The PI control adjusts the control signal
gradually to the demand of the system, in
order to optimize the control result This
optimization must be applied very cautiously
in case of surface heating and cooling
DE
EN
CZ
ES
FR
GR
HU
IT
NL
PL
RO
RS
RU
SE
TR
53

Advertisement

Table of Contents
loading

This manual is also suitable for:

Nea hct 230 v

Table of Contents