Advertisement

Quick Links

Swissphone Telecom AG, Fälmisstrasse 21, 8833 Samstagern, Switzerland.
Service Manual
DV09A VHF
Version 1.1
May 2012
Storage: LN-DB\DV09A\Service Manual
Swissphone Telecom
Page 1 / 23

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the DV09A and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for SwissPhone DV09A

  • Page 1 Swissphone Telecom AG, Fälmisstrasse 21, 8833 Samstagern, Switzerland. Service Manual DV09A VHF Version 1.1 May 2012 Storage: LN-DB\DV09A\Service Manual Swissphone Telecom Page 1 / 23...
  • Page 2: Table Of Contents

    IDEA reset ..........................19     8.2.2 Status ............................. 19     8.2.3 Delete all ..........................19     Test mode ..........................20     8.3.1 Test Pocsag ........................... 20     8.3.2 Test LCD ..........................20 Swissphone Telecom Page 2 / 23...
  • Page 3 List of testing points ......................... 22     10.1 Testing points at the basic-print ....................22     10.2 Testing points at the sub-print ....................23     10.3 Testing points of the TTS-Modul ....................23 Swissphone Telecom Page 3 / 23...
  • Page 4: Document

    Minor corrections Purpose This manual describes all the necessary information required to undertake all the necessary service operations on the DV09A UHF, such as changing the reception frequency, functional checks of individual circuit blocks, etc. Abbreviations and terms Alternating Current...
  • Page 5: References

    References DV09A VHF TPH V1_1.doc Schematic drawing DV09A VHF Basis/ Sub Print: 0421.2561 Component assignment plan layer DV09A VHF Basis/ Sub Print: 0421.2505 0421.2506 Schematic drawing DV09A speech PCB 0421.2261 Component assignment plan layer DV09A speech PCB 0421.2205 0421.2206 Swissphone Telecom...
  • Page 6: Tuning Frequency Change Instructions

     Activate the pager's test mode Via PSW: Tools -> POCSAG -> Radio mode -> Switched on Via buttons: Press the Scroll button while inserting the battery and Test «POCSAG» -> chose mode tuning Swissphone Telecom Page 6 / 23...
  • Page 7: Settings

    To get reproducible results, the device is evaluated in the TEM cell. Place the completely assembled receiver with its display upside down and its antenna in direction to the signal feeding (as shown below). The test is configured to prove whether the DV09A possesses the following call sensitivities: Swissphone Telecom...
  • Page 8 3 of 4 calls at -102 dBm (TEM cell, order no.: 0352000 "free field measure box TEMCELL 1700") The limiting values of the sensitivity have to be reached at the lower as well as at the higher test frequency. Swissphone Telecom Page 8 / 23...
  • Page 9: Function Testing

    5VDC connector. CRO / Frequency counter RF generator PSWplus Voltmeter Power supply 1.5V Interface device Service adapter SA629 PSWplus tool (Service) When you press «Tools» in the PSWplus (service) software, the following menu appears: Swissphone Telecom Page 9 / 23...
  • Page 10: General

    The number of programmed OAP and IDEA keys will be read out. System time The pagers time can be set at the push of a button. The system time of your PC will be used. Swissphone Telecom Page 10 / 23...
  • Page 11: Module Test

    48 mV -15 mV The voltage measurement calibration for the DV09A must be done at a battery voltage of 1.300 V. Keep an eye on the feeding connection during the calibration process. Make sure that the TTS module is switched off because the high current will distort the measurement.
  • Page 12: Pocsag

    This is about the tuning of the PLL reference oscillator. In contrast to VHF the value for UHF is not fixed. It must be corrected because the quartz is temperature dependent. 1. Turn on or off temperature compensations Turn off the temperature compensation first before retuning the reference oscillator. Swissphone Telecom Page 12 / 23...
  • Page 13 It is recommended that if you define the parameters of the battery configuration 4 on your own, you should adapt the predefined values of the configurations 1 to 3 if possible. Swissphone Telecom Page 13 / 23...
  • Page 14 A six digit number can be stored into every device to track service works. It can be entered and programmed at: PSWplus  «Device information»  «Production»  «Repair number». The code can be both numeric and alphanumeric. Swissphone Telecom Page 14 / 23...
  • Page 15: Basis- And Sub-Print Measurements

     Different control voltages will be fed to the varactor diode.  Tune oscillator until the frequency matcher +/- 1ppm. VDD load PSWplus  «Tools»  «Module Test»  «TTS library» Set volume to «5» Swissphone Telecom Page 15 / 23...
  • Page 16: Gain Lf Amplifier

    PSWplus  «Tools»  «POCSAG»  «Radio mode»  «Switched on» Current area: 0.5mA < I < 1.3mA 4.17 Current T51 (1 mixer) Measure the voltage between TP90 and TP50. The current must be I = Measured value / 10. Swissphone Telecom Page 16 / 23...
  • Page 17: Current Zf (Ic61)

    10 shunt resistance. Attention: do not switch the shunt into the measurement pipe before the pager is switched off. PSWplus  «Tools»  «General»  «Switch off pager» Current area: 0.1mA < I < 0.3mA Swissphone Telecom Page 17 / 23...
  • Page 18: Test And Measurement At The Speech-Print

    PSWplus  «Main configuration»  «Device information»  «Channel spacing» Changing the frequency band The pager will be equipped for a special frequency band during production. The service is not intended to change the frequency band. Swissphone Telecom Page 18 / 23...
  • Page 19: Mode Of Operation

    Mode of operation Normal mode When you insert a new battery into the DV09A, the receiver is switched on and will run in normal mode. The same will happen when you press and hold the confirmation button while the pager is switched off.
  • Page 20: Test Mode

    Network 1 and Network 2 will be scanned lower: Tuning frequency -1MHz tuning: Tuning frequency for measuring sensitivity (average frequency) upper: Tuning frequency + 1MHz 8.3.2 Test LCD In Test LCD, each of the following displays can be shown: Swissphone Telecom Page 20 / 23...
  • Page 21: Test Tts

    TTS module is switched on  Mode speech  TTS module speaks the following text: «Test: DV09A receiver by Swissphone 1234567890»  Volume 1, 2, … 8  Volume setting, level 6 is the nominal volume with max. 7% distortion ...
  • Page 22: Advices To Assembly / Disassembly

    /LOWBAT (Flash Programmer Interface) RX (Flash Programmer Interface) /RESET (Flash Programmer Interface) VDD (Flash Programmer Interface) SCLK_FL (Flash Programmer Interface) CNVSS (Flash Programmer Interface) GND (Flash Programmer Interface) 2.5 V reference voltage GND-A BAT+ Swissphone Telecom Page 22 / 23...
  • Page 23: Testing Points At The Sub-Print

    LF_RX (LF signal from receiver) 10.3 Testing points of the TTS-Modul TP-Nr. Signal Debug UART TX Debug UART RX DEBUG PSWITCH VDDIO USB_DP (USB) USB_DM (USB) VDD5V (USB) GND (USB) +1.8V +1.2V VDDS (VDD switched) Swissphone Telecom Page 23 / 23...