Viking RAD-AMP User Manual page 3

Amplified remote access device

Advertisement

C. Installing the Auxiliary Contact Closure
Connect a 4-wire modular cord from the RAD-AMP Line Out jack to the
625A jack. Test the contact closure operation by calling into the RAD-
AMP and verifying proper operation. Note: The RAD-AMP is factory
configured with this feature disabled. To
activate this feature see section F in
Programming. The Red-Green pair is the
outgoing line of the RAD-AMP, while the
Yellow-Black pair provides the auxiliary
contact closure.
P
r
o
g
r
a
m
m
P
r
o
g
r
a
m
m
A. Line Extender Mode
To access programming in the "Line Extender" mode, call into the LINE IN port. After the RAD-AMP answers, enter a
the security code, factory set to V-I-K-I-N-G (845464). The RAD-AMP will beep twice indicating that programming has been
accessed. It is recommended that the factory security code be changed. While programming, if 20 seconds elapse between Touch
Tones, the RAD-AMP will disconnect. All valid Touch Tone programming sequences are acknowledged with a double beep. A triple
beep indicates that a mistake has been made. Note: If a "Priority 2" access code is used, program the "PABX outside line num-
ber" with the Touch Tone required to access a C.O. line from a PABX extension.
Line Extender Quick Programming Features
Set the RAD-AMP to Line Extender mode (factory set) ...........................................
Set the RAD-AMP to Call Diverter mode (see section B) ........................................
Set the RAD-AMP to Telecommuting Extender mode (see section C) .....................
Security code (6 digits 0-9) (factory set to 845464) ..................................................
"Priority 1" access code (enter 6 digits, no digits disables) (factory disabled) ..........
"Priority 2" access code (enter 6 digits, no digits disables) (factory disabled) ..........
PABX outside line number (enter 1 digit, no digit disables) (factory set to 9) ............
SO-24A mode enabled (see Operation section D) ..................................................
SO-24A mode disabled (factory setting, see Operation section D) .........................
Maximum call timer (enter 2 digits*, no digits disables - factory disabled) .................
Ring delay (1-9) (factory set to 1) .............................................................................
Alert tones On (call progress beeps) (factory enabled) ............................................
Alert tones Off ..........................................................................................................
Enable dial tone detection (for installations without CPC or busy signal) .................
Disable dial tone detection (factory setting) .............................................................
Exit programming and disconnect ...........................................................................
Set all programming features to factory settings ......................................................
* Note: Call timer digits specified as follows: 00 = 15 seconds, 01-99 = .5 - 49.5 minutes in .5 minute increments.
B. Call Diverter Mode
To access programming in the "Call Diverter" mode, call into the LINE IN port. After the called party answers, enter a
the security code, factory set to V-I-K-I-N-G (845464). The RAD-AMP will beep twice indicating that programming has been
accessed. It is recommended that the factory security code be changed. While programming, if 20 seconds elapses between Touch
Tones, the RAD-AMP will disconnect. All valid Touch Tone programming sequences are acknowledged with a double beep. A triple
beep indicates that a mistake has been made.
Call Diverter Quick Programming Features
Set the RAD-AMP to Line Extender mode (see section A) .......................................
Set the RAD-AMP to Call Diverter mode .................................................................
Set the RAD-AMP to Telecommuting Extender mode (see section C) .....................
Security code (6 digits 0-9) (factory set to 845464) ..................................................
Call Diverter number (1-32 digits) ............................................................................
To enter a "
" in the Call Diverter number ................................................................
To enter a "#" in the Call Diverter number ................................................................
To enter a 1 second pause in the Call Diverter number ............................................
Maximum call timer (enter 2 digits*, no digits disables - factory disabled) .................
Ring delay (1-9) (factory set to 1) .............................................................................
Enable dial tone detection (for installations without CPC or busy signal) .................
Disable dial tone detection (factory setting) .............................................................
Exit programming and disconnect ...........................................................................
Set all programming features to factory settings ......................................................
* Note: Call timer digits specified as follows: 00 = 15 seconds, 01-99 = .5 - 49.5 minutes in .5 minute increments.
Output of RAD-AMP
i
n
g
i
n
g
Rear View of
the RAD-AMP
600 Ohms
Green
Enter Digits
1
2
3
6 digits
6 digits
6 digits
1 digit
✱ ✱
#
2 digits
1 digit
9
0
5
6
# 7
###
Enter Digits
1
2
3
6 digits
1-32 digits
✱ ✱
#
8
2 digits
1 digit
5
6
# 7
###
LINE IN
LINE OUT
REMOTE
SWITCH
Black
4-Wire Modular
Red
To device
requiring
Yellow
contact closure
- then - Enter Memory Location
then
# 47
then
# 45
then
# 46
then
# 44
then
# 48
# 49
then
- then - Enter Memory Location
#47
then
then
# 00
then
# 48
then
# 49
USE ONLY LISTED
CLASS 2 POWER
SOURCE 12V DC
500mA MAXIMUM
Cable
followed by
followed by
3