Download Print this page

Viking RAD-AMP User Manual page 2

Amplified remote access device

Advertisement

D
e
f
i
n
i
t
i
o
n
D
e
f
i
n
i
t
i
o
n
Line Extender: The mode of operation in which the RAD-AMP provides remote access to an analog station of a PABX,
KSU or a second C.O. line. This is ideal for bridging long distance areas or allowing remote employees to use company
lines for toll calls.
Call Diverter: The mode of operation in which the RAD-AMP forwards a call to a pre-programmed phone number.
Telecommuting Extender: The mode of operation in which the RAD-AMP forwards calls to one of nine pre-programmed
numbers as well as providing remote access to an analog PABX/KSU station or C.O. line, including all features available
to that station or C.O. line.
Security Code: The code programmed into the RAD-AMP that allows access to all programming features.
Priority 1 Access Code: The code programmed into the RAD-AMP that allows a remote user to have complete access
to the PABX or KSU including outside toll calls.
"Priority 2" Access Code: The code programmed into the RAD-AMP that allows a remote user to have limited access to
the PABX or KSU, effectively blocking outside line access.
I
n
s
t
a
l
l
a
t
i
o
I
n
s
t
a
l
l
a
t
i
o
A. Line Extender/Call Diverter Installation
Connect the incoming phone line to the LINE IN jack on
the back panel of the RAD-AMP. Connect a second
phone line or 600 ohm audio device to the LINE OUT
jack. For normal operation, the front panel switch
should be set to the ON position and the remote night
switch contacts must be open.
Note: The RAD-AMP is factory configured
as a "Line Extender" . To change the mode
of operation or operating parameters, see
the "Programming" section and follow the
specific programming section for the
desired
mode (Line Extender, Call
Diverter or Telecommuting Extender ).
B. Telecommuting Extender Installation
To utilize the Telecommuting extender mode for remote employees, the RAD-AMP must be installed as shown below
and DIP switches 3 and 4 must be set as shown before programming the unit.
Internal View of the RAD-AMP
2
s
s
n
n
Note:
switch must be placed in the OFF
position to utilize this feature.
OFF
ON
Rear View of the RAD-AMP
LINE IN
REMOTE
SWITCH
Open = OFF
Closed = ON
Optional Night Mode
Remote Switch
The front panel ON/OFF
Remote
Employee
Dials Out to Remote
Employee
LINE OUT
USE ONLY LISTED
CLASS 2 POWER
SOURCE 12V DC
500mA MAXIMUM
Center Pair
(Red & Green)
Incoming C.O. Line
or Analog PABX/KSU
Extension
Rear View of the RAD-AMP
LINE IN
LINE OUT
USE ONLY LISTED
CLASS 2 POWER
REMOTE
SOURCE 12V DC
500mA MAXIMUM
SWITCH
Remote Employee's
Analog PABX/KSU
120V AC/13.8V AC
Adapter
(included)
Outgoing Second
C.O. Line or Analog
PABX/KSU Extension
120V AC/13.8V AC
Adapter (included)
PABX/KSU

Advertisement

loading