Page 7
FIRE, EXPLOSION, BURN INJURY, CARBON MONOIXDE POISIONING The cooking appliance must be completely separated and/or sealed from other air moving or air consuming devices such as, but not limited to furnaces, microwaves ovens, clothes dryers, cooling fans and doors or drawers in common cabinets.
Page 8
NEGATIVE DRAFT caused by air moving appliances may draw the top burner flame down into or toward the cooktop resulting in cooktop damage, burn hazard, explosion possibility and/or carbon monoxide poisoning. POSITIVE DRAFT may blow out the top burner flame during use resulting in an explosion and/or fire hazard and/or injury to the occupants of the vehicle.
Page 10
construction and the back of the appliance. The minimum distance from the center of the rear burner to the combustible wall behind the range is 9". The minimum distance from the center of the rear burner to the combustible side wall next to the range is 7.25". The side cabinet that is located between the appliance and the combustible construction has a minimum height requirement from the cooking surface to the bottom of the cabinet of 18"...
Page 11
The minimum horizontal distance between overhead cabinets must not be less than width of the appliance. The maximum depth of the cabinets installed above the top surface of the cooking sections can be no more than 13" (330mm). Any opening in the wall behind the appliance and in the floor under the appliance shall be sealed.
Page 12
Slide the front foot bracket under the front of the range and push until bracket is up against the front foot. Secure bracket to the floor. (Recommend #8-15 x 1" wood screw, not provided). 0.654in The contour line of back panel of appliance 3.07in Move the appliance to the final position 3.08”...
Page 13
button to the desired oven temperature. Rev.10.16.23 CCD-0008340...
Page 14
5 to 10 seconds. 4.To adjust to the desired flame, push and rotate the burner control knob. Rev.10.16.23 CCD-0008340...
Page 17
quality: All combustion flames need to be visually checked to determine their flame quality. 1. Yellow tips on outer cones-Normal for LP gas operation. 2. Yellow flames-Abnormal for any gas operation; call for service. lf burner flame looks like 3, the range should not be used until it is serviced. Call for service.
Page 18
loose joint properly. -Leak testing of the appliance shall be conducted according to the manufacturer’s instructions. Do not use a flame to check for gas leaks. Use a brush to spread a soapy water mixture around the area you are checking.
Page 19
and or cooktop (maximum pan size = 10 inches). when not in use. Rev.10.16.23 CCD-0008340...
Page 20
Top Glass Cover Drawer Rev.10.16.23 CCD-0008340...
Page 21
Hold burner knob in for at least 5 seconds once the burner is lit. Rev.10.16.23 CCD-0008340...
Page 22
If there is a spill on the gas range, cooktop, grate(s), burner caps, or any other component of the gas range, clean the spill right away (make sure the range has cooled prior to cleaning) as leaving any spill can result in the discoloration or staining of your range or stainless steel.
Page 23
occur, clean the egg spill when the cooktop has cooled down. Do not allow the egg spill 1. For 12V DC service only. Do not connect to higher voltage. Connect only to protected circuit fused for not more than 5 Amps. Rev.10.16.23 CCD-0008340...
Need help?