Current steps:
1) Run SecureCRT.exe
2) TV power on.
3) SecureCR tool print information can appear or not.
How to distribute the three status?
1) appearing "
<< MStar >>#
2) Rolling many informmation automatically that meaning is in Supernova status;
3) No any print information that meaning the eMMC of board is no program.
Stop board serial with SecureCRT
1) In mboot status:
<< MStar >>#
Input "du" and "enter" key to ensure, then close the SecureCRT window.
2) In Supernova status:
Input "00112233"and "enter" key to ensure, then close the SecureCRT window.
3) If no any print information with SecureCRT,then can directly close the SecureCRT window.
4.2.4 How to collect log files
1) TV AC power on
2) USB connect correctly
3) Mstar serial Tool connect correctly
4) When questions appear , computer run SecureCRT input lowercase " getlog" ,if fails input
another"05328087".then rolls the lots of log print message.
5) Save the log print message to soft engineer.
" that meaning is in Mboot status